{"product_id":"abb-tpsg4ai-1khl015623r0001-analog-input-module","title":"ABB TPSG4AI 1KHL015623R0001 وحدة PLC جديدة تمامًا ومتوفرة في المخزون","description":"\u003cp\u003eThe \u003cstrong\u003eABB TPSG4AI 1KHL015623R0001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTPSG4AI\u003c\/strong\u003e Analog Input Module, converts field analog signals into digital process data for control and monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTPSG4AI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering Code\u003c\/td\u003e\n\u003ctd\u003e1KHL015623R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e4 analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Ranges\u003c\/td\u003e\n\u003ctd\u003e0\/4-20 mA, 0-10 VDC configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit \/ 16-bit, configuration dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Analog Signal Acquisition and I\/O Integration\u003c\/h3\u003e\n\u003cp\u003eThe TPSG4AI accepts four configurable analog input channels for current and voltage signal acquisition. Input ranges include 0\/4-20 mA and 0-10 VDC according to configuration.\u003c\/p\u003e\n\u003cp\u003eThe module converts field-level analog measurements into digital values for processing by connected control equipment. Signal wiring should maintain separation from high-voltage power conductors and high-current switching circuits.\u003c\/p\u003e\n\u003cp\u003eThe DIN-rail mounting format supports installation inside standard industrial control cabinets. IP20 construction requires installation within an enclosure providing suitable protection against accidental contact and environmental contamination.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What analog signal ranges does the TPSG4AI support?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied specifications identify configurable 0\/4-20 mA and 0-10 VDC analog input ranges.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many analog input channels are provided?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The module provides four analog input channels for field signal acquisition.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What resolution is available for analog conversion?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied data specifies 12-bit or 16-bit resolution, depending on configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module on a compatible DIN rail inside a suitable control cabinet.\u003c\/li\u003e\n\u003cli\u003eVerify the 24 VDC nominal supply before connecting field wiring.\u003c\/li\u003e\n\u003cli\u003eSeparate analog signal cables from AC power, motor cables, contactors, and high-current conductors.\u003c\/li\u003e\n\u003cli\u003eUse shielded instrumentation cable where electromagnetic interference could affect low-level analog measurements.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shields according to the control-system grounding scheme and avoid unintended ground loops.\u003c\/li\u003e\n\u003cli\u003eConfirm the configured input range before applying 0\/4-20 mA or 0-10 VDC field signals.\u003c\/li\u003e\n\u003cli\u003eObserve polarity and terminal assignments during current-loop and voltage-signal wiring.\u003c\/li\u003e\n\u003cli\u003eVerify enclosure conditions because the specified IP20 protection does not provide environmental protection by itself.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52750311293213,"sku":"TPSG4AI 1KHL015623R0001","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/TPSG4AI1KHL015623R00012.jpg?v=1788940338","url":"https:\/\/www.6gcontrols.com\/ar\/products\/abb-tpsg4ai-1khl015623r0001-analog-input-module","provider":"6G Controls","version":"1.0","type":"link"}