Configured for temperature, voltage, resistance, and thermocouple measurement in the Modicon X80 platform, the Schneider Electric BMXART0814 (BMXART0814 analog input module) provides eight isolated low-level analog input channels with 15 bits + sign resolution. It supports RTD, thermocouple, resistance, and voltage input ranges with external cold junction compensation by Pt100 probe.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | BMXART0814 |
| Brand | Schneider Electric |
| Series | Modicon X80 |
| Product Type | Analog input module |
| Analog Inputs | 8 |
| Input Level | Low level |
| Channel Isolation | Isolated between channels |
| Input Types | Voltage, resistance, RTD, thermocouple |
| Analog Input Resolution | 15 bits + sign |
| A/D Conversion | Sigma delta, 16 bits |
| Voltage Ranges | +/- 40 mV, +/- 80 mV, +/- 160 mV, +/- 320 mV, +/- 640 mV, +/- 1.28 V |
| Resistance Inputs | 400 Ohm and 4000 Ohm, 2-wire, 3-wire, or 4-wire |
| RTD Inputs | Cu 10, Ni 100, Ni 1000, Pt 100, Pt 1000 |
| Thermocouple Types | B, E, J, K, L, N, R, S, T, U |
| Cold Junction Compensation | External by Pt100 probe |
| Nominal Read Cycle | 400 ms with temperature probe; 200 ms with thermocouple |
| Common Mode Rejection | 120 dB at 50/60 Hz |
| Differential Mode Rejection | 60 dB at 50/60 Hz |
| Digital Filtering | First order |
| Measurement Resolution | 0.1 deg C for supported temperature inputs |
| Maximum Wiring Resistance | Up to 500 Ohm depending on sensor and wiring configuration |
| Electrical Connection | 40-way, 2 connectors |
| Current Consumption | 150 mA at 3.3 VDC; 50 mA at 24 VDC |
| Weight | 0.165 kg |
| Operating Temp | 0 to 60 deg C |
| Storage Temp | -40 to 85 deg C |
| Relative Humidity | 5 to 95% at 55 deg C, non-condensing |
| IP Rating | IP20 |
| Vibration Resistance | 3 gn |
| Shock Resistance | 30 gn |
| Operating Altitude | 0 to 2000 m; 2000 to 5000 m with derating |
| Recalibration | Internal |
| Open Circuit Detection | Supported for specified RTD and thermocouple inputs |
| Status Indication | RUN, channel diagnostic, ERR, and I/O LEDs |
| Certifications | CE, EAC, UL, CSA, Merchant Navy, RCM |
| Standards | IEC 61131-2, IEC 61000-6-4, IEC 61000-6-2, EN 61010-2-201 |
| Protective Treatment | Standard version |
The module specifications identify eight isolated inputs, low-level input operation, 15 bits + sign resolution, and a 150 mA current consumption at 3.3 VDC. The environmental ratings and physical weight are specified as IP20, 0 to 60 deg C operating temperature, and 0.165 kg net weight.
I/O Density and Signal Conditioning
The BMXART0814 provides eight analog channels within a Modicon X80 module. The input circuitry accepts multiple low-level voltage ranges, resistance configurations, RTD types, and thermocouple types. Channel-to-channel isolation separates the individual input circuits. The module applies first-order digital filtering and provides common-mode rejection of 120 dB and differential-mode rejection of 60 dB at 50/60 Hz.
For temperature measurement, cold junction compensation is performed externally using a Pt100 probe. The specified measurement and temperature-drift values vary according to the selected sensor or input range. Internal recalibration and open-circuit detection are provided for the supported sensor types.
Frequently Asked Questions
Q: How many analog channels does the BMXART0814 provide?
A: It provides 8 analog input channels with channel-to-channel isolation.
Q: What power consumption is specified for the module?
A: The module consumes 150 mA at 3.3 VDC and 50 mA at 24 VDC.
Q: How is cold junction compensation implemented?
A: Cold junction compensation is external and uses a Pt100 probe.
Field Installation Guidelines
- Install the module in the compatible Modicon X80 rack and secure the module mechanically before connecting field wiring.
- Use the specified 40-way connector arrangement for electrical connections.
- Separate low-level analog and thermocouple wiring from high-current power and switching conductors where practical.
- Maintain correct sensor wiring configuration for 2-wire, 3-wire, or 4-wire resistance and RTD measurements.
- Apply shield termination according to the installation grounding scheme and avoid creating unintended ground loops.
- For thermocouple channels, use the appropriate thermocouple wiring and verify the external Pt100 connection required for cold junction compensation.
- Confirm the selected input range and sensor type before commissioning each channel.
- Observe the IP20 enclosure limitation and install the module inside an enclosure providing the required environmental protection.
- Keep ambient operating temperature within 0 to 60 deg C and account for altitude derating above 2000 m.
الدفع: تحويل مصرفي (T/T)، ويسترن يونيون.
ميناء الشحن: شيامن.
مدة التجهيز: عادةً من يوم إلى 3 أيام عمل بعد تأكيد الدفع (وفقًا لتوافر المخزون).
التوصيل worldwide: نشحن قطع الأتمتة الصناعية إلى العملاء حول العالم. تُدرج تكلفة الشحن ضمن عرض السعر الخاص بطلب عرض الأسعار (RFQ).
الأسئلة الشائعة
الأسئلة الشائعة حول عروض الأسعار والشحن والضمان والإرجاعانقر على طلب عرض سعر في صفحة المنتج وأرسل إلينا رقم القطعة والكمية المطلوبة وبلد الوجهة. سيرد فريق المبيعات لدينا بتوفر المنتج حاليًا وسعره ووقت التسليم التقديري.
تُجهَّز المنتجات المتوفرة عادةً بعد الدفع وتأكيد الطلب. تُشحن معظم الطلبات من مستودعنا في الصين، مع أن موقع الشحن قد يختلف حسب المخزون الحالي.
نعم. نشحن قطع الأتمتة الصناعية إلى العملاء في جميع أنحاء العالم. تعتمد تكلفة الشحن ومدة النقل على الوجهة ووزن الطرد وحجم المنتج ومتطلبات الاستيراد المحلية.
نستخدم عادةً خدمات شركات الشحن الدولية مثل DHL وFedEx وUPS وغيرها. ويمكن اختيار شركة الشحن وفقًا للوجهة وسرعة التسليم وحجم الشحنة ومتطلبات العميل.
تخضع منتجاتنا عمومًا لضمان لمدة 12 شهرًا. كما يمكن إرجاع المنتجات المؤهلة بموجب سياسة استرداد الأموال خلال 30 يومًا. يُرجى التواصل مع فريقنا قبل إرجاع أي منتج لتأكيد الشروط المعمول بها وتعليمات الإرجاع.
قد يعجبك أيضًا
منشورات المدونة
أخبار الأتمتة الصناعية، والأدلة التقنية، وتحديثات المنتجات.