{"product_id":"schneider-electric-bmxddi3202k-modicon-x80-discrete-input-module","title":"Schneider Electric BMXDDI3202K Modicon X80 Discrete Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMXDDI3202K\u003c\/strong\u003e is a 32-channel discrete input module from the Modicon X80 I\/O platform, designed for Modicon M340 and M580 PLC architectures. It processes 24 VDC positive-logic (sink) field signals using a high-density 40-pin connector interface, allowing compact field wiring via pre-assembled cords or Telefast connection sub-bases.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXDDI3202K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e32 isolated discrete inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (positive logic \/ sink)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Wiring Mode\u003c\/td\u003e\n\u003ctd\u003e2-wire or 3-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e2.5 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eState 1 Voltage Threshold\u003c\/td\u003e\n\u003ctd\u003egreater than or equal to 11 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eState 0 Voltage Threshold\u003c\/td\u003e\n\u003ctd\u003eless than or equal to 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eState 1 Current Threshold\u003c\/td\u003e\n\u003ctd\u003egreater than or equal to 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eState 0 Current Threshold\u003c\/td\u003e\n\u003ctd\u003eless than or equal to 0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e9600 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Response Time\u003c\/td\u003e\n\u003ctd\u003e4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Response Time\u003c\/td\u003e\n\u003ctd\u003e7 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Power Supply\u003c\/td\u003e\n\u003ctd\u003e19 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Supply Fault Threshold\u003c\/td\u003e\n\u003ctd\u003eless than 14 VDC (fault), greater than 18 VDC (OK)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e160 mA at 3.3 VDC (backplane), 121 mA DC typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e3.9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 V AC (50\/60 Hz, 1 min) primary\/secondary; 500 VDC (1 min) between channel groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot-Swapping\u003c\/td\u003e\n\u003ctd\u003eYes (fallback supported)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal LED Indicators\u003c\/td\u003e\n\u003ctd\u003e1 green RUN, 1 red ERR, 1 red I\/O, 32 green channel status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating Type\u003c\/td\u003e\n\u003ctd\u003eStandard version (non-conformal coated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 m (2000 to 5000 m with derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e134.6 mm x 32 mm x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.112 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Processing and Electrical Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe module accepts 24 VDC sink inputs compliant with IEC 61131-2 and IEC 60947-5-2 for 2-wire and 3-wire sensors. With a 9600 Ohm input impedance and 2.5 mA nominal input current at 24 VDC, it limits field power draw while guaranteeing State 1 recognition at 11 V or higher and State 0 at 5 V or lower.\u003c\/p\u003e\n\u003cp\u003eBuilt-in sensor voltage supervision monitors the external 19 to 30 VDC field supply, triggering a fault state below 14 VDC and restoring normal status above 18 VDC. Input paralleling is not supported on this module.\u003c\/p\u003e\n\u003ch3\u003eConnector Interface and Mounting\u003c\/h3\u003e\n\u003cp\u003eUnlike screw-terminal Modicon X80 modules, the \u003cstrong\u003eBMXDDI3202K\u003c\/strong\u003e uses a 40-pin connector (Pfostenstecker \/ HE10 style) to accommodate all 32 channels within a single 32 mm wide slot. Field connections require pre-wired 40-pin cordsets (such as BMXFCW or BMXFCC series) or Advantys Telefast ABE7 passive connection sub-bases.\u003c\/p\u003e\n\u003cp\u003eThe module mounts directly into a Modicon X80 backplane rack (for M340 or M580 local\/remote I\/O drops) and is secured with two captive mounting screws. Front-panel diagnostics include module-level RUN, ERR, and I\/O LEDs alongside individual green status LEDs for each of the 32 channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the BMXDDI3202K connect to field sensors?A: It uses a 40-pin connector rather than removable screw terminals. You must connect it using pre-assembled 40-pin cables (like BMXFCW503 or BMXFCC series) or route signals through an Advantys Telefast ABE7 terminal block.\u003c\/p\u003e\n\u003cp\u003eQ: What is the difference between BMXDDI3202K and the coated version?A: The BMXDDI3202K is the standard version without conformal coating, rated for 0 to 60 deg C operation and pollution degree 2. Applications requiring hardened conformal coating use the ruggedized variant (typically suffixed with H).\u003c\/p\u003e\n\u003cp\u003eQ: Does the BMXDDI3202K support hot-swapping in a running rack?A: Yes, the module supports hot-swapping fallback when installed in compatible Modicon X80 racks, allowing replacement without powering down the entire PLC station.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68109659635997,"sku":"BMXDDI3202K","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXDDI3202K2.jpg?v=1794907660","url":"https:\/\/www.6gcontrols.com\/cs\/products\/schneider-electric-bmxddi3202k-modicon-x80-discrete-input-module","provider":"6G Controls","version":"1.0","type":"link"}