{"product_id":"schneider-electric-bmxnoe0110h-modicon-m340-ethernet-tcp-ip-network-module","title":"Schneider Electric BMXNOE0110H Modicon M340 Ethernet TCP\/IP Network Module","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMXNOE0110H\u003c\/strong\u003e is an Ethernet TCP\/IP network module for the Modicon M340 automation platform. It provides RJ45 10BASE-T\/100BASE-TX connectivity for industrial network communication, supporting services such as Modbus TCP messaging, I\/O scanning, Global Data, FDR server and configurable web access. The module features Transparent Ready Class C30 functionality, conformal coating and an extended operating temperature range.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEthernet Communication and Network Services\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXNOE0110H connects the Modicon M340 platform to Ethernet TCP\/IP networks through an RJ45 interface supporting 10\/100 Mbit\/s communication. Its network services allow the automation system to exchange process data, access device information and communicate with other Ethernet-based equipment.\u003c\/p\u003e\n\u003cp\u003eSupported communication services include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eModbus TCP messaging for industrial data exchange.\u003c\/li\u003e\n\u003cli\u003eI\/O scanning for communication with configured remote devices.\u003c\/li\u003e\n\u003cli\u003eGlobal Data for exchanging variables between network devices.\u003c\/li\u003e\n\u003cli\u003eFDR (Faulty Device Replacement) server.\u003c\/li\u003e\n\u003cli\u003eSNMP network management.\u003c\/li\u003e\n\u003cli\u003eRack Viewer for accessing rack information.\u003c\/li\u003e\n\u003cli\u003eConfigurable web server and Data Editor.\u003c\/li\u003e\n\u003cli\u003eSOAP XML Web service (server).\u003c\/li\u003e\n\u003cli\u003eBandwidth management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Transparent Ready Class C30 designation identifies the module's Ethernet communication capability within Schneider Electric's Transparent Ready architecture.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMemory and Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module is supplied with a BMXRWSC016M Flash memory card. Its internal RAM capacity is 16,000 kB, supporting application backup and standard web server functions. The supplied card is used for application saving and activation of the standard web server.\u003c\/p\u003e\n\u003cp\u003eInternal rack power supplies the module, so no separate external 24 VDC power connection is specified for its operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStatus Indication and Reset Control\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXNOE0110H provides six local LED indicators for monitoring communication and module status:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eETH ACT: Ethernet network activity.\u003c\/li\u003e\n\u003cli\u003eRUN: Processor running status.\u003c\/li\u003e\n\u003cli\u003eETH STS: Ethernet network status.\u003c\/li\u003e\n\u003cli\u003eETH 100: Ethernet data rate indication.\u003c\/li\u003e\n\u003cli\u003eCARD ERR: Memory card fault.\u003c\/li\u003e\n\u003cli\u003eERR: Processor or system fault.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA front-panel RESET pushbutton provides cold restart control. This function is distinct from normal network communication and can be used to restart the module when required by the applicable maintenance procedure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXNOE0110H uses conformal coating for operation in more demanding industrial environments. Its specified operating temperature range is -25 to 70 deg C, with relative humidity of 10-95% without condensation.\u003c\/p\u003e\n\u003cp\u003eThe IP20 enclosure rating indicates protection against access to hazardous parts with fingers and against solid foreign objects of 12.5 mm or larger. It does not provide protection against water ingress.\u003c\/p\u003e\n\u003cp\u003eAdditional environmental classifications include gas resistance to Gx under ISA S71.04, gas resistance class 3C4 and dust and sand resistance class 3S4 under IEC 60721-3-3.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXNOE0110H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon M340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEthernet TCP\/IP Network Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Application\u003c\/td\u003e\n\u003ctd\u003eSevere environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcept\u003c\/td\u003e\n\u003ctd\u003eTransparent Ready\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransparent Ready Class\u003c\/td\u003e\n\u003ctd\u003eC30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port Type\u003c\/td\u003e\n\u003ctd\u003e10BASE-T \/ 100BASE-TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Speed\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Connection\u003c\/td\u003e\n\u003ctd\u003e1 twisted pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eEthernet TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Services\u003c\/td\u003e\n\u003ctd\u003eModbus TCP, I\/O Scanning, Global Data, FDR, SNMP, SOAP XML\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal RAM\u003c\/td\u003e\n\u003ctd\u003e16,000 kB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory Card\u003c\/td\u003e\n\u003ctd\u003eBMXRWSC016M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eInternal power supply via rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e90 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset Control\u003c\/td\u003e\n\u003ctd\u003eRESET pushbutton, cold restart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Indicators\u003c\/td\u003e\n\u003ctd\u003eETH ACT, RUN, ETH STS, ETH 100, CARD ERR, ERR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10-95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, RCM, EAC, Merchant Navy, ATEX Zone 2\/22, IECEx Zone 2\/22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location Classification\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Classification\u003c\/td\u003e\n\u003ctd\u003eGas Gx, 3C4; Dust and Sand 3S4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3595864009735\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary function of the Schneider BMXNOE0110H?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It is an Ethernet TCP\/IP network module for the Modicon M340 platform. It provides RJ45 network connectivity and supports services including Modbus TCP messaging, I\/O scanning, Global Data and SNMP network management.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between BMXNOE0110H and an M340 processor module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The BMXNOE0110H is a dedicated Ethernet network module, whereas an M340 processor module executes the control application and manages PLC operations. The BMXNOE0110H provides network communication services rather than serving as the main application processor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the BMXNOE0110H require an external 24 VDC power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No separate external supply is specified. The module receives its operating power internally through the Modicon M340 rack. Its rated current consumption is 90 mA at 24 VDC.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68137286598941,"sku":"BMXNOE0110H","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXNOE0110H2_b3cfa0d3-c270-423b-bf94-027618468e86.jpg?v=1795165807","url":"https:\/\/www.6gcontrols.com\/cs\/products\/schneider-electric-bmxnoe0110h-modicon-m340-ethernet-tcp-ip-network-module","provider":"6G Controls","version":"1.0","type":"link"}