{"product_id":"schneider-bmxcps3020-modicon-x80-power-supply-module","title":"Schneider BMXCPS3020 Modicon X80 Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMXCPS3020\u003c\/strong\u003e is an isolated DC power supply module in the Modicon X80 range. It supplies power to a Modicon X80 I\/O rack and its installed modules, providing separate 24 VDC and 3.3 VDC secondary outputs for the I\/O and processor supply and the rack logic supply. It accepts an isolated 24-48 VDC input and includes secondary-circuit overload, overvoltage, and short-circuit protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply Function\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXCPS3020 converts its DC input into the secondary power required by the X80 rack. Its outputs serve two different functions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 VDC output:\u003c\/strong\u003e Supplies the I\/O modules and processor, with a rated secondary power of 31.2 W.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3.3 VDC output:\u003c\/strong\u003e Supplies I\/O module logic, with a rated secondary power of 15 W.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSeparating these output functions allows the rack to supply both module operating power and internal logic power. The maximum power dissipation of the module is 8.5 W.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput and Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module accepts an isolated DC input with a nominal voltage range of 24-48 VDC. The specified primary voltage limits are 18-62.4 VDC, providing the permitted input operating range.\u003c\/p\u003e\n\u003cp\u003eThe protection functions differ between the primary and secondary circuits. The primary circuit has an internal fuse that is not accessible, while the secondary circuit includes overload, overvoltage, and short-circuit protection for the 24 V sensor supply.\u003c\/p\u003e\n\u003cp\u003eThe specified inrush current is 30 A at 24 VDC and 60 A at 48 VDC. These values should be considered when evaluating upstream DC power supply capacity and input circuit protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Connections and Indicators\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXCPS3020 provides separate connectors for power input and alarm relay connections:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOne 5-pin connector for the power supply input and protective earth.\u003c\/li\u003e\n\u003cli\u003eOne 2-pin connector for the alarm relay.\u003c\/li\u003e\n\u003cli\u003eOne green LED indicating that rack voltage is OK.\u003c\/li\u003e\n\u003cli\u003eOne RESET push button for a cold start.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe maximum specified cable distance between devices depends on the copper conductor cross-section: 10 m with 1.5 mm2 cable or 15 m with 2.5 mm2 cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXCPS3020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModicon X80 Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24-48 VDC, isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e18-62.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e0.83 A at 48 VDC; 1.65 A at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Power - 24 VDC\u003c\/td\u003e\n\u003ctd\u003e31.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Power - 3.3 VDC\u003c\/td\u003e\n\u003ctd\u003e15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Current - 24 VDC\u003c\/td\u003e\n\u003ctd\u003e1.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Current - 3.3 VDC\u003c\/td\u003e\n\u003ctd\u003e4.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e30 A at 24 VDC; 60 A at 48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI2t at Power-On\u003c\/td\u003e\n\u003ctd\u003e1 A2.s at 24 VDC; 3 A2.s at 48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower-On Charge\u003c\/td\u003e\n\u003ctd\u003e0.2 A.s at 24 VDC; 0.3 A.s at 48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e8.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e4,600,000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eInternal, non-accessible fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eOverload, overvoltage and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicator\u003c\/td\u003e\n\u003ctd\u003eGreen - rack voltage OK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset Function\u003c\/td\u003e\n\u003ctd\u003eCold-start RESET button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connections\u003c\/td\u003e\n\u003ctd\u003e1 x 5-pin power connector; 1 x 2-pin alarm relay connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Distance\u003c\/td\u003e\n\u003ctd\u003e10 m with 1.5 mm2 copper cable; 15 m with 2.5 mm2 copper cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Interruption Immunity\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 10 MOhm, primary\/earth and primary\/secondary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1500 V, primary\/earth and primary\/secondary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e3 Gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e30 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% at 55 deg C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Coating\u003c\/td\u003e\n\u003ctd\u003eTC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0-2,000 m; derating required from 2,000 to 5,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e3595863908985\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Carbon Footprint\u003c\/td\u003e\n\u003ctd\u003e457 kg CO2 eq.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXCPS3020 is designed for installation in a Modicon X80 rack. It must be inserted into the module carrier and secured with two screws. Its stated backplane compatibility excludes the \u003cstrong\u003eBMEXBP..02\u003c\/strong\u003e backplane family.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer specifies compatibility with Modicon X80 module carriers, subject to the stated backplane restriction. Before replacement, verify the installed rack reference and backplane type rather than relying solely on the X80 product family designation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards and Certifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXCPS3020 is specified with the following certifications and standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertifications: CE, RCM, Merchant Navy, CSA, EAC and UL.\u003c\/li\u003e\n\u003cli\u003eStandards: EN 61131-2, EN 61000-6-4, EN 61000-6-2 and EN 61010-2-201.\u003c\/li\u003e\n\u003cli\u003eEU directives: 2014\/35\/EU (Low Voltage) and 2014\/30\/EU (Electromagnetic Compatibility).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the 24 VDC and 3.3 VDC outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 24 VDC output supplies the I\/O modules and processor, with 31.2 W of rated power. The 3.3 VDC output supplies I\/O module logic, with 15 W of rated power. Both outputs serve different power requirements within the X80 rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the BMXCPS3020 compatible with all Modicon X80 backplanes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The specified compatibility excludes BMEXBP..02 backplanes. Check the exact backplane reference before selecting this power supply for a rack replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What input voltage can the BMXCPS3020 accept?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Its nominal isolated DC input range is 24-48 VDC, with specified primary voltage limits of 18-62.4 VDC. The input current is 1.65 A at 24 VDC and 0.83 A at 48 VDC. Upstream power supply and protection selection should also account for its specified inrush current.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68095770263837,"sku":"BMXCPS3020","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXCPS30202.jpg?v=1794821859","url":"https:\/\/www.6gcontrols.com\/de\/products\/schneider-bmxcps3020-modicon-x80-power-supply-module","provider":"6G Controls","version":"1.0","type":"link"}