{"product_id":"schneider-bmxdai0805-modicon-x80-discrete-input-module","title":"Schneider BMXDAI0805 Modicon X80 Discrete Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMXDAI0805\u003c\/strong\u003e is an 8-channel isolated AC discrete input module in the Modicon X80 range. It receives 200-240 V AC field signals and transfers their ON\/OFF states to the PLC system. Each channel supports 2-wire or 3-wire sensor wiring, with AC signal filtering, channel-level LED diagnostics, and a 0-60 deg C operating temperature range.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXDAI0805\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eIsolated, capacitive AC inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e200-240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e10.4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Wiring\u003c\/td\u003e\n\u003ctd\u003e2-wire or 3-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Limits\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e21,000 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuaranteed State 1 Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 159 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuaranteed State 0 Voltage\u003c\/td\u003e\n\u003ctd\u003e10 MOhm at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Between Channels and Terminals\u003c\/td\u003e\n\u003ctd\u003e1500 V for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Current Consumption\u003c\/td\u003e\n\u003ctd\u003e76 mA at 3.3 V DC; 93.6 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e126 mA at 3.3 V DC; 154.8 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e4.73 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Protection\u003c\/td\u003e\n\u003ctd\u003e0.5 A fast-blow fuse per channel group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Diagnostics\u003c\/td\u003e\n\u003ctd\u003eRUN, ERR, I\/O and individual channel LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e1,700,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% at 55 deg C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0-2,000 m; derating required from 2,000 to 5,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e3 Gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e30 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e103.7 x 32 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Channels and Signal Processing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXDAI0805 provides eight electrically isolated AC input channels. Its capacitive input circuits detect field voltage changes and convert them into discrete states for PLC processing. The module supports 200-240 V AC signals and is designed for proximity sensor connections using 2-wire or 3-wire configurations.\u003c\/p\u003e\n\u003cp\u003eThe input thresholds define the voltage conditions for recognizing logical states. A voltage of at least 159 V represents a guaranteed ON state, while a voltage of 40 V or less represents a guaranteed OFF state. The AC input filtering introduces a 10 ms activation response and a 20 ms deactivation response, which should be considered when evaluating signal timing.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostics and Electrical Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides individual green LEDs for channel diagnostics, together with RUN and ERR indicators for module status. An additional red I\/O indicator supports identification of module I\/O faults.\u003c\/p\u003e\n\u003cp\u003eAn external 0.5 A fast-blow fuse is required for each channel group. The module has a specified isolation withstand voltage of 1500 V for one minute between channels and terminals. Its voltage monitoring function identifies sensor supply conditions above 164 V AC as normal and below 80 V AC as a sensor fault.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModicon X80 Platform Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXDAI0805 belongs to the Modicon X80 I\/O family, which provides a common I\/O platform for Modicon M340 and Modicon M580 automation systems. It can be used in local or remote I\/O configurations, subject to the applicable PLC platform and rack configuration.\u003c\/p\u003e\n\u003cp\u003eThe module uses a removable 20-way terminal block connection. Supported terminal block styles include cage-clamp, screw and removable spring-clamp connections. The module must be installed on a compatible module rack and secured using two screws.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Compliance Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe standard BMXDAI0805 operates from 0 to 60 deg C and has an IP20 protection rating. Its specified humidity range is 5-95% at 55 deg C without condensation. Applications above 2,000 m require additional derating.\u003c\/p\u003e\n\u003cp\u003eThe supplied product information identifies the following standards and approvals:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eEN 61000-6-5\u003c\/li\u003e\n\u003cli\u003eEN 61850-3\u003c\/li\u003e\n\u003cli\u003eCE, UL, CSA, RCM, EAC and UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of field signals does the BMXDAI0805 accept?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It accepts eight isolated 200-240 V AC discrete input signals. The inputs support 2-wire or 3-wire sensor wiring, including compatible AC proximity sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the ON and OFF input thresholds?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The guaranteed ON threshold is at least 159 V AC, while the guaranteed OFF threshold is 40 V AC or lower. Voltages between these thresholds should not be treated as guaranteed logical states.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the BMXDAI0805 require external fuse protection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The specified protection is one external 0.5 A fast-blow fuse per channel group. The correct fuse rating and field wiring arrangement must be observed during installation.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68096671973661,"sku":"BMXDAI0805","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXDAI08052.jpg?v=1794824551","url":"https:\/\/www.6gcontrols.com\/de\/products\/schneider-bmxdai0805-modicon-x80-discrete-input-module","provider":"6G Controls","version":"1.0","type":"link"}