{"product_id":"schneider-bmxxbp0800h-modicon-x80-ruggedized-backplane","title":"Schneider BMXXBP0800H Modicon X80 Ruggedized Backplane","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMXXBP0800H\u003c\/strong\u003e is an 8-slot ruggedized backplane for the Modicon X80 automation platform. It provides the rack mounting structure and X-bus connections for compatible processor, power supply, I\/O and application-specific modules. The backplane supports panel, mounting plate and 35 mm DIN rail installation, with an extended operating temperature range for severe environmental conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBackplane Architecture and Module Connections\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXXBP0800H provides \u003cstrong\u003e8 X-bus slots\u003c\/strong\u003e for mounting compatible Modicon modules. The rack accommodates a BMXP34 processor, BMXCPS power supply, I\/O modules and specific application modules. Its backplane connections provide the electrical and communication paths required for modules to exchange data within the rack.\u003c\/p\u003e\n\u003cp\u003eThe backplane also has one XBE expansion-module connector for rack expansion. The XBE connection is intended for the rack expansion module; it should not be confused with an Ethernet network interface. Schneider's Modicon X80 catalog identifies the BMXXBP series as X-bus backplanes, while the BMEXBP series provides dual X-bus and Ethernet connections.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRuggedized Design and Environmental Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe H version is specified for severe environmental conditions. It uses conformal coating and supports an operating ambient temperature range of -25 to +70 deg C, with relative humidity from 10% to 95% without condensation.\u003c\/p\u003e\n\u003cp\u003eThe IP20 protection rating describes the enclosure protection level and does not indicate a sealed or waterproof assembly. The specified environmental characteristics should be considered when selecting the rack for an industrial control cabinet.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMounting and Installation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXXBP0800H supports three mounting arrangements:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePanel mounting using four M4, M5 or M6 screws.\u003c\/li\u003e\n\u003cli\u003eMounting plate installation using four M4, M5 or M6 screws.\u003c\/li\u003e\n\u003cli\u003eMounting on a 35 mm symmetrical DIN rail using clips.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts 372.8 mm width and 103.7 mm height determine the rack space required in the cabinet. The mounting arrangement should be selected according to the cabinet structure and mechanical installation requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXXBP0800H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRuggedized Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Slots\u003c\/td\u003e\n\u003ctd\u003e8 X-bus slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Application\u003c\/td\u003e\n\u003ctd\u003eSevere environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Modules\u003c\/td\u003e\n\u003ctd\u003eBMXP34 processor, BMXCPS power supply, I\/O modules, specific application modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Connection\u003c\/td\u003e\n\u003ctd\u003e1 XBE connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.21 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel, mounting plate or 35 mm symmetrical DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFastening\u003c\/td\u003e\n\u003ctd\u003e4 M4\/M5\/M6 screws or DIN rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e372.8 x 103.7 x 17.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3595864009384\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards and Certifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe product documentation identifies the following certifications and standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertifications: CE, UL, CSA, RCM, EAC, UKCA and Merchant Navy.\u003c\/li\u003e\n\u003cli\u003eHazardous-area classifications: ATEX Zone 2\/22 and IECEx Zone 2\/22.\u003c\/li\u003e\n\u003cli\u003eStandards: EN\/IEC 61131-2, EN\/IEC 61010-2-201, UL 61010-2-201, CSA C22.2 No 61010-2-201, IACS E10, EN\/IEC 61000-6-5 and EN\/IEC 61850-3.\u003c\/li\u003e\n\u003cli\u003eEnvironmental resistance: Gas resistance class Gx (ISA S71.04), 3C4 gas resistance and 3S4 dust and sand resistance under IEC 60721-3-3.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the BMXXBP0800H an Ethernet backplane?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The BMXXBP0800H is an 8-slot X-bus backplane. The BMEXBP0800H is a separate Modicon X80 model with dual X-bus and Ethernet backplane functionality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which modules can be installed on the BMXXBP0800H?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified compatible module types include BMXP34 processors, BMXCPS power supplies, I\/O modules and specific application modules. The exact module reference should be checked against the system configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the BMXXBP0800H support hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Schneider Electric identifies hot-swapping as a feature for most I\/O modules used with this backplane. This does not mean that every module can be replaced under power. The applicable module documentation and system operating conditions must be checked before replacement.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68165881626909,"sku":"BMXXBP080008","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXXBP0800H.jpg?v=1795506660","url":"https:\/\/www.6gcontrols.com\/es\/products\/schneider-bmxxbp0800h-modicon-x80-ruggedized-backplane","provider":"6G Controls","version":"1.0","type":"link"}