{"product_id":"schneider-electric-bmep58cpros3-modicon-m580-safety-coprocessor","title":"Schneider Electric BMEP58CPROS3 Modicon M580 Safety CoProcessor","description":"\u003cp\u003eConfigured for safety processing between the Modicon M580 Safety processor and rack-based control architecture, the \u003cstrong\u003eSchneider Electric BMEP58CPROS3\u003c\/strong\u003e (\u003cstrong\u003eBMEP58CPROS3\u003c\/strong\u003e Safety CoProcessor) provides direct processor-level execution through the internal rack power and backplane interface. It is a coated processor module with SIL 3 capability, IP20 protection, and Modicon X80 compatibility.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMEP58CPROS3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon M580\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSafety CoProcessor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Function\u003c\/td\u003e\n\u003ctd\u003eSafety CoProcessor module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Level\u003c\/td\u003e\n\u003ctd\u003eSIL 3, PL = e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003eInternal power supply via rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e295 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e64 x 130 x 135 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.849 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e3 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e15 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% at 55 deg C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 m; 2000 to 5000 m with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e946000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Platform\u003c\/td\u003e\n\u003ctd\u003eModicon M580 Safety processor and Modicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Software\u003c\/td\u003e\n\u003ctd\u003eEcoStruxure Control Expert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, RCM, EAC, UKCA, ATEX Zone 2\/22, IECEx Zone 2\/22, TUV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2, IEC 61010-2-201, UL 61010-2-201, IEC 61508 and related standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eM580 Safety Processor and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eBMEP58CPROS3 is installed in the Modicon M580 rack next to the M580 Safety processor. The module receives its operating power through the rack and interfaces with the rack architecture rather than using a separate field power input.\u003c\/p\u003e\n\u003cp\u003eThe specified installation requires the CoProcessor to be mounted adjacent to the CPU and secured with two screws at the top of the module. Modicon X80 I\/O, backplane and cable components can be used within the supported M580 architecture.\u003c\/p\u003e\n\u003cp\u003eThe module provides status indication through RUN, ERR, DL, SRUN and SMOD LEDs for processor operation, fault status, download activity, safety mode and maintenance mode.\u003c\/p\u003e\n\u003ch3\u003eSafety and Environmental Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe module is specified for SIL 3 and PL = e applications and uses conformal coating for environmental protection. Environmental specifications include IP20 protection, 3 gn vibration resistance and 15 gn shock resistance.\u003c\/p\u003e\n\u003cp\u003eThe published environmental characteristics include gas resistance class Gx under ISA S71.04, gas resistance class 3C4 and dust and sand resistance class 3S4 under IEC 60721-3-3. ATEX and IECEx Zone 2\/22 certifications are also specified.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does BMEP58CPROS3 require a separate power supply?\u003c\/p\u003e\n\u003cp\u003eA: No. The module receives its operating power internally through the Modicon M580 rack. The specified current consumption is 295 mA at 24 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: Where should the BMEP58CPROS3 be installed in the rack?\u003c\/p\u003e\n\u003cp\u003eA: The CoProcessor must be installed in the rack next to the M580 Safety processor and secured using the specified two top mounting screws.\u003c\/p\u003e\n\u003cp\u003eQ: Which software is specified for configuration and programming?\u003c\/p\u003e\n\u003cp\u003eA: The module operates within the Modicon M580 architecture using EcoStruxure Control Expert.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the rack, M580 Safety processor and associated X80 components are compatible before installation.\u003c\/li\u003e\n\u003cli\u003eInstall the BMEP58CPROS3 directly next to the M580 Safety processor as specified by the product documentation.\u003c\/li\u003e\n\u003cli\u003eSecure the module mechanically with the designated mounting screws before energizing the rack.\u003c\/li\u003e\n\u003cli\u003eKeep the module within the specified -25 to 60 deg C operating temperature range.\u003c\/li\u003e\n\u003cli\u003eMaintain the required environmental conditions for humidity, vibration, shock and altitude.\u003c\/li\u003e\n\u003cli\u003eDo not obstruct the module ventilation area or exceed the IP20 installation environment.\u003c\/li\u003e\n\u003cli\u003eFollow the applicable cabinet grounding and EMC practices for the complete M580 installation.\u003c\/li\u003e\n\u003cli\u003eRoute power and communication wiring according to the system installation documentation and maintain physical separation from high-noise power circuits where required.\u003c\/li\u003e\n\u003cli\u003eConfirm the RUN, ERR, DL, SRUN and SMOD indicators after installation and during commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52997845778717,"sku":"BMEP58CPROS3","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMEP58CPROS32_65889b54-6821-409f-915f-78d3321db328.jpg?v=1789956631","url":"https:\/\/www.6gcontrols.com\/fa\/products\/schneider-electric-bmep58cpros3-modicon-m580-safety-coprocessor","provider":"6G Controls","version":"1.0","type":"link"}