{"product_id":"schneider-electric-bmxsai0410-modicon-x80-safety-analog-input-module","title":"Schneider Electric BMXSAI0410 Modicon X80 Safety Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eBMXSAI0410\u003c\/strong\u003e is a safety analog input module for the Schneider Electric Modicon X80 I\/O platform, engineered specifically for Modicon M580 safety systems. It provides 4 isolated 4-20 mA current inputs with 16-bit A\/D conversion, internal recalibration, and out-of-range current detection. Featuring a red housing coating designated for safety components, it supports functional safety architectures up to SIL 3, Category 4, and PLd, and operates exclusively with a Modicon M580 Safety CPU.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXSAI0410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSafety Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent, 4-20 mA (high level)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog\/Digital Conversion\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resolution\u003c\/td\u003e\n\u003ctd\u003e13-bit (0 to 12,500 counts; 2 uA measurement resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Value Format\u003c\/td\u003e\n\u003ctd\u003e+\/- 10,000 (default); +\/- 32,000 (user scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Read Cycle Time\u003c\/td\u003e\n\u003ctd\u003e6 ms for 4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Error\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 0.3% of full scale at -25 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e30 ppm\/deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e286 Ohm (0.1% internal resistor precision, 15 ppm\/deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermitted Input Overload\u003c\/td\u003e\n\u003ctd\u003e25 mA (maximum conversion range: 0-25 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Filtering\u003c\/td\u003e\n\u003ctd\u003eSecond-order digital filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrosstalk Attenuation\u003c\/td\u003e\n\u003ctd\u003eMinimum 120 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e20-way removable terminal block (1 connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 VDC (channel-to-channel); 1500 VDC (channel-to-ground and channel-to-bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e200 mA at 3.3 VDC; 115 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e1 green RUN LED, 1 red ERR LED, 1 red I\/O LED, 4 green channel diagnostic LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Ratings\u003c\/td\u003e\n\u003ctd\u003eUp to SIL 3, Category 4, PLd; CIP Safety compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eTUV Rheinland, CE, UL, CSA, ATEX, IECEx, EAC, RCM, Merchant Navy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2, IEC 61010-2-201, UL 61010-2-201, CSA C22.2 No 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% at 55 deg C (without condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0 to 2,000 m (2,000 to 5,000 m with derating factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Resistance\u003c\/td\u003e\n\u003ctd\u003eGas class Gx \/ 3C4; Dust and sand class 3S4; Salt level 2; Mold and fungal spore class 3B2 (IEC 60721-3-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Resistance\u003c\/td\u003e\n\u003ctd\u003eVibration: 3 gn; Shock: 15 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e463,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.143 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x L)\u003c\/td\u003e\n\u003ctd\u003e5.5 cm x 18.0 cm x 26.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Processing and Isolation Architecture\u003c\/h3\u003e\n\u003cp\u003eEach of the four channels measures 4-20 mA process signals across an internal 286 Ohm precision resistor (0.1% tolerance) and converts the signal via a 16-bit A\/D converter with second-order digital filtering. The module scans all 4 channels within a nominal read cycle time of 6 ms, maintaining a measurement resolution of 2 uA and an accuracy within 0.3% of full scale across the -25 to 60 deg C operating range.\u003c\/p\u003e\n\u003cp\u003eGalvanic isolation is rated at 500 VDC between individual channels and 1500 VDC from channels to ground and backplane bus, preventing ground loops and cross-channel interference (minimum 120 dB crosstalk attenuation). Built-in diagnostics monitor for out-of-range current conditions up to the 25 mA overload limit and report status via dedicated green channel LEDs alongside module-level RUN, ERR, and I\/O indicators.\u003c\/p\u003e\n\u003ch3\u003eCompatibility and Installation Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Requirement:\u003c\/strong\u003e Although part of the common Modicon X80 I\/O family, the \u003cstrong\u003eBMXSAI0410\u003c\/strong\u003e is dedicated to Modicon M580 safety architectures and can only operate with a Modicon M580 Safety CPU. It cannot be used in standard non-safety M340 or standard M580 configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Placement and Clearance:\u003c\/strong\u003e The module can be installed in either a local main rack or a remote drop rack (Ethernet or X-bus). Note that the physical height of this safety I\/O module exceeds the standard Modicon X80 rack height; cabinet layouts must account for the extra vertical clearance before mounting the rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Field signals connect via a single 20-way removable terminal block, allowing module replacement without disturbing field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the BMXSAI0410 be used with a standard Modicon M340 or non-safety M580 CPU?\u003c\/strong\u003eA: No. While it uses the Modicon X80 form factor, the BMXSAI0410 is strictly dedicated to Modicon M580 safety systems and requires a Safety CPU to function.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What physical clearance is needed when mounting the BMXSAI0410 in a rack?\u003c\/strong\u003eA: The height of the BMXSAI0410 module is greater than the height of a standard Modicon X80 Ethernet or X-bus rack. Ensure sufficient vertical space above or below the rack in the enclosure prior to installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How are channel faults and out-of-range signals indicated on the module?\u003c\/strong\u003eA: The module features continuous current out-of-range detection up to 25 mA, displaying channel-specific diagnostics on 4 individual green LEDs along with module-level red ERR and I\/O fault LEDs.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68155753922845,"sku":"BMXSAI0410","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXSAI0410.jpg?v=1795426728","url":"https:\/\/www.6gcontrols.com\/fa\/products\/schneider-electric-bmxsai0410-modicon-x80-safety-analog-input-module","provider":"6G Controls","version":"1.0","type":"link"}