{"product_id":"schneider-electric-140nrp31200-quantum-fibre-converter","title":"Schneider Electric 140NRP31200 Quantum Fibre Converter","description":"\u003ch3\u003e\n\u003cstrong\u003eOverview\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider Electric 140NRP31200\u003c\/strong\u003e is a multi-mode Ethernet fibre converter developed for the Modicon Quantum automation platform. Designed for industrial Ethernet communication systems, this module converts standard copper Ethernet signals into fiber-optic transmission for improved network distance, electromagnetic immunity, and communication reliability.\u003c\/p\u003e\n\u003cp\u003eThe converter supports dual-channel 100 Mbps Ethernet communication with LC-type fiber optic connections and RJ45 copper interfaces. Its compact design and industrial-grade construction make it suitable for process control systems, distributed automation networks, and plant-wide communication infrastructures.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e140NRP31200\u003c\/strong\u003e module is engineered for stable operation in harsh industrial environments and supports long-distance fiber communication between network devices and PLC systems.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eKey Features\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\nDual-channel industrial Ethernet fibre converter\n\u003c\/li\u003e\n\u003cli\u003e\nSupports 100 Mbps Ethernet communication\n\u003c\/li\u003e\n\u003cli\u003e\nMulti-mode fiber optic transmission\n\u003c\/li\u003e\n\u003cli\u003e\nTwo LC fiber optic ports\n\u003c\/li\u003e\n\u003cli\u003e\nTwo RJ45 Ethernet ports\n\u003c\/li\u003e\n\u003cli\u003e\nExtended communication distance up to 3000 meters\n\u003c\/li\u003e\n\u003cli\u003e\nHigh resistance to electrical interference and signal noise\n\u003c\/li\u003e\n\u003cli\u003e\nCompact module for Modicon Quantum systems\n\u003c\/li\u003e\n\u003cli\u003e\nLED diagnostics for link and communication monitoring\n\u003c\/li\u003e\n\u003cli\u003e\nIndustrial operating temperature range\n\u003c\/li\u003e\n\u003cli\u003e\nCE certified industrial communication device\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003e\nParameter\n\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003e\nSpecification\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nManufacturer\n\u003c\/td\u003e\n\u003ctd\u003e\nSchneider Electric\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nProduct Series\n\u003c\/td\u003e\n\u003ctd\u003e\nModicon Quantum\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nProduct Type\n\u003c\/td\u003e\n\u003ctd\u003e\nEthernet Fibre Converter\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nModel\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e140NRP31200\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nFiber Type\n\u003c\/td\u003e\n\u003ctd\u003e\nMulti-Mode\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nEthernet Speed\n\u003c\/td\u003e\n\u003ctd\u003e\n100 Mbps\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nFiber Connector\n\u003c\/td\u003e\n\u003ctd\u003e\n2 x LC\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nCopper Ethernet Ports\n\u003c\/td\u003e\n\u003ctd\u003e\n2 x RJ45\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nCommunication Channels\n\u003c\/td\u003e\n\u003ctd\u003e\n2 Channels\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nOperating Wavelength\n\u003c\/td\u003e\n\u003ctd\u003e\n1310 nm\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nMaximum Fiber Distance\n\u003c\/td\u003e\n\u003ctd\u003e\n2000 m (50\/125 µm)\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nMaximum Fiber Distance\n\u003c\/td\u003e\n\u003ctd\u003e\n3000 m (62.5\/125 µm)\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nReceiver Sensitivity\n\u003c\/td\u003e\n\u003ctd\u003e\n-30 dBm\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nDetected Silence\n\u003c\/td\u003e\n\u003ctd\u003e\n-45 dBm\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nRise\/Fall Time\n\u003c\/td\u003e\n\u003ctd\u003e\n3 ns\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nBus Current Requirement\n\u003c\/td\u003e\n\u003ctd\u003e\n1000 mA\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nInrush Current\n\u003c\/td\u003e\n\u003ctd\u003e\n1 A at 5 VDC\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nPower Dissipation\n\u003c\/td\u003e\n\u003ctd\u003e\n5 W\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nHousing Material\n\u003c\/td\u003e\n\u003ctd\u003e\nPolycarbonate (PC)\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nStatus Indicators\n\u003c\/td\u003e\n\u003ctd\u003e\nRDY, ERR, STS1, FX1 ACT, STS2, FX2 ACT\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nOperating Temperature\n\u003c\/td\u003e\n\u003ctd\u003e\n0°C to 60°C\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nStorage Temperature\n\u003c\/td\u003e\n\u003ctd\u003e\n-40°C to 85°C\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nRelative Humidity\n\u003c\/td\u003e\n\u003ctd\u003e\n0% to 95% non-condensing\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nOperating Altitude\n\u003c\/td\u003e\n\u003ctd\u003e\nUp to 2000 m\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nProtection Certifications\n\u003c\/td\u003e\n\u003ctd\u003e\nCE, TÜV, C-Tick\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nCompliance Standards\n\u003c\/td\u003e\n\u003ctd\u003e\nUL 508, CSA C22.2 No 142, FM Class 1 Div 2\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n​Weight\n\u003c\/td\u003e\n\u003ctd\u003e\n0.55 kg\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cstrong\u003eCommunication and Network Performance\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e140NRP31200\u003c\/strong\u003e fibre converter is designed to extend Ethernet communication across industrial facilities where long cable runs or electrically noisy environments make copper Ethernet impractical.\u003c\/p\u003e\n\u003cp\u003eBy converting Ethernet signals from RJ45 copper to LC multi-mode fiber, the module helps maintain communication integrity in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\nManufacturing plants\n\u003c\/li\u003e\n\u003cli\u003e\nProcess automation systems\n\u003c\/li\u003e\n\u003cli\u003e\nWater treatment facilities\n\u003c\/li\u003e\n\u003cli\u003e\nPower generation sites\n\u003c\/li\u003e\n\u003cli\u003e\nRemote I\/O installations\n\u003c\/li\u003e\n\u003cli\u003e\nHigh-interference industrial zones\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eLED Diagnostic Indicators\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eIntegrated front-panel LEDs provide fast visual diagnostics for network status and module health:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\nRDY: Module operational status\n\u003c\/li\u003e\n\u003cli\u003e\nERR: Internal fault indication\n\u003c\/li\u003e\n\u003cli\u003e\nSTS1 \/ STS2: Fiber link status\n\u003c\/li\u003e\n\u003cli\u003e\nFX1 ACT \/ FX2 ACT: Channel communication activity\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese indicators simplify troubleshooting during commissioning and maintenance.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003ePhysical Characteristics\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003e\nDimension\n\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003e\nValue\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nWidth\n\u003c\/td\u003e\n\u003ctd\u003e\n40.34 mm\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nHeight\n\u003c\/td\u003e\n\u003ctd\u003e\n250 mm\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nDepth\n\u003c\/td\u003e\n\u003ctd\u003e\n103.85 mm\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\nEthernet-to-fiber conversion\n\u003c\/li\u003e\n\u003cli\u003e\nIndustrial network extension\n\u003c\/li\u003e\n\u003cli\u003e\nPLC communication infrastructure\n\u003c\/li\u003e\n\u003cli\u003e\nFiber optic backbone systems\n\u003c\/li\u003e\n\u003cli\u003e\nModicon Quantum network installations\n\u003c\/li\u003e\n\u003cli\u003e\nHigh-noise industrial Ethernet environments\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eFAQ\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\n\u003cstrong\u003eWhat type of fiber does the 140NRP31200 support?\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe module supports multi-mode fiber optic communication using LC connectors.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eHow many Ethernet channels are available?\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe converter supports two independent Ethernet fiber channels.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eCan this module be used in harsh industrial environments?\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eYes. The module is designed for industrial applications and complies with UL, CSA, FM, and CE standards.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eWhat is the maximum communication distance?\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe transmission distance reaches up to 3000 meters depending on the fiber cable specification used.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eDoes the module support standard RJ45 Ethernet connections?\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eYes. It includes two RJ45 Ethernet ports for copper network integration.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52762221347101,"sku":"140NRP31200","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/140NRP31200_1000.jpg?v=1787222857","url":"https:\/\/www.6gcontrols.com\/fr\/products\/schneider-electric-140nrp31200-quantum-fibre-converter","provider":"6G Controls","version":"1.0","type":"link"}