{"product_id":"schneider-bmxcps4002-modicon-x80-redundant-power-supply-module","title":"Schneider BMXCPS4002 Modicon X80 Redundant Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider BMXCPS4002\u003c\/strong\u003e is a Modicon X80 power supply module designed for redundant power architectures in PLC and PAC systems. It accepts a 100-240 V AC primary supply and provides separate 3.3 V DC and 24 V DC secondary outputs for module logic and I\/O power distribution. Network-based diagnostics and redundancy monitoring support power supply status supervision in the control system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply Function and Redundant Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXCPS4002 supplies the internal power requirements of an X80 module rack. Its 3.3 V DC output powers I\/O module logic, while the 24 V DC output supplies I\/O module power and the processor, subject to the specified load conditions.\u003c\/p\u003e\n\u003cp\u003eThe module supports redundant power architecture and provides redundancy status information. Its diagnostic functions include temperature monitoring, redundancy testing, operating time and remaining service-life information. These diagnostics can be accessed over the network.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Protection and Status Monitoring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe secondary circuits incorporate overload, overvoltage and short-circuit protection. These functions protect the downstream power distribution circuits against specified electrical fault conditions. The primary circuit also has internal protection.\u003c\/p\u003e\n\u003cp\u003eThree green LEDs indicate voltage availability, redundancy status and overall power supply status. A RESET button provides a cold-start reset function.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXCPS4002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRedundant Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e85-264 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Limits\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApparent Power\u003c\/td\u003e\n\u003ctd\u003e0.13 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e0.55 A at 240 V; 1.01 A at 115 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e30 A at 120 V; 60 A at 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Output\u003c\/td\u003e\n\u003ctd\u003e3.3 V DC and 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Power\u003c\/td\u003e\n\u003ctd\u003e18 W at 3.3 V DC; 40 W at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Current\u003c\/td\u003e\n\u003ctd\u003e5.5 A at 3.3 V DC; 1.67 A at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e8.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Interruption Immunity\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eSecondary overload, overvoltage and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eTemperature monitoring, redundancy test, operating time and remaining operating life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e3 green LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset Function\u003c\/td\u003e\n\u003ctd\u003eCold-start RESET button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connections\u003c\/td\u003e\n\u003ctd\u003e2-pin alarm relay connector; 5-pin power supply and protective earth connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 100 MOhm, primary\/earth and primary\/secondary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1500 V primary\/secondary; 1500 V primary\/earth; 2300 V sensor supply\/secondary; 500 V sensor output\/ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% at 55 deg C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0-2,000 m; derating required from 2,000 to 5,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eTC, Humiseal 1A33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Classification\u003c\/td\u003e\n\u003ctd\u003e3C3 and 3C4 according to IEC 60721-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e3 Gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e30 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e792,000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.51 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e3606480927560\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Carbon Footprint\u003c\/td\u003e\n\u003ctd\u003e496 kg CO2 eq.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Connections and Installation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXCPS4002 has separate connectors for the alarm relay and incoming power supply. The 5-pin connector provides the power supply and protective earth connections, while the 2-pin connector is used for the alarm relay.\u003c\/p\u003e\n\u003cp\u003eInstallation requirements include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module in a Modicon X80 module rack.\u003c\/li\u003e\n\u003cli\u003eSecure the power supply using two screws.\u003c\/li\u003e\n\u003cli\u003eUse the supplied removable 5-way and 2-way terminal blocks.\u003c\/li\u003e\n\u003cli\u003eObserve the specified operating temperature and altitude derating conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module has an IP20 protection rating and is intended for installation within an appropriate equipment enclosure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications and Standards\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe product documentation identifies the following certifications and standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertifications: CE, RCM, Merchant Navy, CSA, EAC and UL.\u003c\/li\u003e\n\u003cli\u003eEN 61131-2\u003c\/li\u003e\n\u003cli\u003eEN 61000-6-4\u003c\/li\u003e\n\u003cli\u003eEN 61000-6-2\u003c\/li\u003e\n\u003cli\u003eEN 61010-2-201\u003c\/li\u003e\n\u003cli\u003eEU Low Voltage Directive 2014\/35\/EU\u003c\/li\u003e\n\u003cli\u003eEU EMC Directive 2014\/30\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the BMXCPS4002 be used in a redundant power supply architecture?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The BMXCPS4002 is specified for redundant power architectures. Its redundancy monitoring functions provide status information for system-level supervision. The actual redundant configuration must follow the applicable Modicon X80 system design requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the two secondary output voltages used for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 3.3 V DC output supplies I\/O module logic, while the 24 V DC output supplies I\/O module power and the processor under the specified load conditions. The rated output powers are 18 W and 40 W respectively.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the BMXCPS4002 provide network diagnostics?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Available diagnostic information includes temperature sensor data, redundancy test results, operating time and remaining operating life. These functions support remote monitoring of the power supply condition.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68096012189981,"sku":"BMXCPS4002","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXCPS40022.jpg?v=1794822963","url":"https:\/\/www.6gcontrols.com\/hr\/products\/schneider-bmxcps4002-modicon-x80-redundant-power-supply-module","provider":"6G Controls","version":"1.0","type":"link"}