{"product_id":"schneider-electric-bmenua0100-modicon-m580-communication-module","title":"Schneider Electric BMENUA0100 Modicon M580 Communication Module","description":"\u003cp\u003eConfigured for OPC UA client communication and IT network data exchange in the Modicon M580 platform, the \u003cstrong\u003eSchneider Electric BMENUA0100\u003c\/strong\u003e (\u003cstrong\u003eBMENUA0100\u003c\/strong\u003e communication module) provides an embedded OPC UA server with Ethernet connectivity, backplane transparency, and diagnostic communication services.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMENUA0100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon M580\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEthernet communication module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eOPC UA server and IT control network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOPC UA Standard\u003c\/td\u003e\n\u003ctd\u003eOPC UA V1.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOPC UA Clients\u003c\/td\u003e\n\u003ctd\u003e10 maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitored Items\u003c\/td\u003e\n\u003ctd\u003e50,000 maximum standard sampling; 2,000 maximum fast sampling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Nodes\u003c\/td\u003e\n\u003ctd\u003e100,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port\u003c\/td\u003e\n\u003ctd\u003e1 x RJ45, 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Medium\u003c\/td\u003e\n\u003ctd\u003eDouble-shielded twisted pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane\u003c\/td\u003e\n\u003ctd\u003eEthernet and X-bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Modules per Rack\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eInternal rack power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 140 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swappable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Redundancy\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHTTPS\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Services\u003c\/td\u003e\n\u003ctd\u003eIPv6, IP forwarding, service forwarding, network segmentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Services\u003c\/td\u003e\n\u003ctd\u003eModbus TCP server, SNMP V1\/V3, NTP V4 client\/server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCybersecurity\u003c\/td\u003e\n\u003ctd\u003eBuilt-in firewall, certificate authentication, RBAC, Syslog, IPSec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e131 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e86.05 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% at 55 deg C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, cULus, RCM, UKCA, EAC, Merchant Navy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModicon M580 Ethernet and OPC UA Communication\u003c\/h3\u003e\n\u003cp\u003eThe BMENUA0100 occupies one Ethernet\/X-bus rack slot and communicates through the M580 Ethernet backplane. Its front Ethernet interface supports 10\/100\/1000 Mbit\/s operation. The embedded OPC UA server supports up to 10 client connections, with up to 40 subscriptions per session.\u003c\/p\u003e\n\u003cp\u003eStandard OPC UA operation provides a minimum publishing interval of 250 ms and a minimum sampling interval of 125 ms. Fast sampling supports a 20 ms minimum sampling interval and 20 ms minimum publishing interval. The module supports up to 100,000 OPC UA nodes.\u003c\/p\u003e\n\u003cp\u003eNetwork functions include IPv6, IP forwarding, service forwarding, network segmentation, Modbus TCP diagnostics, SNMP V1\/V3 network management, and NTP V4 time synchronization. Security functions include HTTPS, certificate-based authentication, role-based access control, Syslog, IPSec, built-in firewall functions, and network physical isolation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the BMENUA0100 be installed while the M580 rack remains powered?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports hot swapping and configuration changes on the fly. Installation and replacement must follow the applicable M580 rack installation procedure.\u003c\/p\u003e\n\u003cp\u003eQ: What is the electrical load of the BMENUA0100 on the rack power supply?\u003c\/p\u003e\n\u003cp\u003eA: The specified current consumption is \u0026lt;= 140 mA at 24 VDC from the internal rack power supply.\u003c\/p\u003e\n\u003cp\u003eQ: What Ethernet connection is provided for OPC UA communication?\u003c\/p\u003e\n\u003cp\u003eA: The module provides one RJ45 Ethernet port supporting 10\/100\/1000 Mbit\/s over double-shielded twisted-pair cabling. Ethernet backplane communication provides transparency between the module and connected M580 system components.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the BMENUA0100 in an Ethernet or X-bus slot of the main rack, within the supported M580 X80 Ethernet backplane configuration. The module occupies one rack slot, with a maximum of two BMENUA0100 modules permitted per rack.\u003c\/p\u003e\n\u003cp\u003eRoute Ethernet cabling separately from high-voltage power conductors and high-current switching circuits where practical. Use the specified shielded twisted-pair Ethernet connection and maintain appropriate cable routing and bend-radius practices.\u003c\/p\u003e\n\u003cp\u003eConnect the module only to the supported rack power system. Verify the rack power budget before installation, accounting for the module's \u0026lt;= 140 mA current consumption at 24 VDC.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning OPC UA communication, configure IP addressing, network segmentation, certificates, user roles, and applicable firewall or IPSec functions according to the M580 cybersecurity configuration. Check the RUN, ERR, ETH MS, ETH NS, STS, and communication bus LEDs during startup and commissioning.\u003c\/p\u003e\n\u003cp\u003eThe module is rated IP20 and should therefore be installed inside the appropriate control enclosure. Maintain the specified 0 to 60 deg C operating temperature and avoid installation locations exposed to condensation or conductive contamination.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52987035779357,"sku":"BMENUA0100","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMENUA01001.jpg?v=1789885642","url":"https:\/\/www.6gcontrols.com\/hr\/products\/schneider-electric-bmenua0100-modicon-m580-communication-module","provider":"6G Controls","version":"1.0","type":"link"}