{"product_id":"schneider-electric-bmxdra0805h-modicon-x80-discrete-output-module","title":"Schneider Electric BMXDRA0805H Modicon X80 Discrete Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMXDRA0805H\u003c\/strong\u003e is an 8-channel normally open (NO) relay discrete output module designed for the Modicon X80 common I\/O platform, supporting Modicon M580 and Modicon M340 Programmable Automation Controllers (PAC). Engineered with conformal coating and an extended operating temperature range of -25 deg C to +70 deg C, this ruggedized module switches 24 to 240 V AC and 24 V DC loads in severe industrial environments.\u003c\/p\u003e\n\u003ch3\u003eOutput Switching and Electrical Performance\u003c\/h3\u003e\n\u003cp\u003eThe BMXDRA0805H provides 8 normally open relay output channels configured with positive discrete output logic. It accommodates a nominal load voltage range of 24 to 240 V AC (19 to 264 V AC operating limits) and 12 to 24 V DC (10 to 34 V DC operating limits), requiring a minimum switching load of 10 mA at 5 V DC to ensure reliable contact closure.\u003c\/p\u003e\n\u003cp\u003eBackplane power draw is 79 mA typical at 3.3 V DC. Output switching response times are less than 10 ms for activation and less than 8 ms for deactivation, making the module suitable for general relay control of solenoids, contactors, and pilot indicators. Channel-to-bus isolation is rated at 2000 V AC (50\/60 Hz for 1 minute) with an insulation resistance exceeding 10 MOhm at 500 V DC.\u003c\/p\u003e\n\u003ch3\u003eRuggedized Construction and Environmental Ratings\u003c\/h3\u003e\n\u003cp\u003eThe \"H\" suffix designates the hardened version featuring conformal coating on the internal printed circuit boards. This protective treatment enables continuous operation from -25 deg C to +70 deg C and up to 95% non-condensing relative humidity at 55 deg C.\u003c\/p\u003e\n\u003cp\u003eThe IP20-rated housing is qualified against corrosive and particulate contaminants under standard industrial classifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGas resistance: Class Gx and Class 3C4\u003c\/li\u003e\n\u003cli\u003eDust and sand resistance: Class 3S4\u003c\/li\u003e\n\u003cli\u003eSalt mist resistance: Level 2\u003c\/li\u003e\n\u003cli\u003eMold growth and fungal spore resistance: Class 3B2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLifecycle Status and Replacement\u003c\/h3\u003e\n\u003cp\u003eSchneider Electric discontinued the BMXDRA0805H on July 1, 2022, with end-of-service scheduled for June 30, 2030. The official direct replacement is the \u003cstrong\u003eSchneider Electric BMXDRA0815H\u003c\/strong\u003e, which retains the 8 NO relay output form factor and conformal coating while expanding the nominal DC switching capability to 24 to 125 V DC.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXDRA0805H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Controllers\u003c\/td\u003e\n\u003ctd\u003eModicon M580, Modicon M340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e8 NO Relay Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Logic\u003c\/td\u003e\n\u003ctd\u003ePositive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 to 240 V AC \/ 12 to 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19 to 264 V AC \/ 10 to 34 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Switching Current\u003c\/td\u003e\n\u003ctd\u003e10 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Consumption\u003c\/td\u003e\n\u003ctd\u003e79 mA typical at 3.3 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 ms (activation), \u0026lt; 8 ms (deactivation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e2000 V AC at 50\/60 Hz for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e2,119,902 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% at 55 deg C (without condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eATEX, CE, CSA, EAC, IECEx, Merchant Navy, RCM, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd\u003eEN 61131-2, EN 61000-6-4, EN 61000-6-2, EN 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.145 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the difference between the BMXDRA0805H and the standard BMXDRA0805?A: The \"H\" suffix indicates a hardened version with conformal coating, extending the operating temperature range to -25 deg C to +70 deg C and adding resistance to corrosive gases (Gx, 3C4), dust\/sand (3S4), salt (Level 2), and mold\/fungi (3B2).\u003c\/p\u003e\n\u003cp\u003eQ: Can the BMXDRA0805H be replaced directly by the BMXDRA0815H?A: Yes. Schneider Electric designates the BMXDRA0815H as the official replacement for the discontinued BMXDRA0805H, offering the same 8 NO relay outputs and severe-environment coating while supporting an expanded 24 to 125 V DC load range.\u003c\/p\u003e\n\u003cp\u003eQ: What is the minimum load required for reliable relay switching on the BMXDRA0805H?A: Each relay output requires a minimum switching current of 10 mA at 5 V DC to maintain proper contact reliability.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68110357299485,"sku":"BMXDRA0805H","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXDRA0805H1.jpg?v=1794910885","url":"https:\/\/www.6gcontrols.com\/hr\/products\/schneider-electric-bmxdra0805h-modicon-x80-discrete-output-module","provider":"6G Controls","version":"1.0","type":"link"}