{"product_id":"schneider-electric-bmexbp0400h-modicon-x80-ruggedized-rack","title":"Schneider Electric BMEXBP0400H Modicon X80 Ruggedized Rack","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMEXBP0400H\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eBMEXBP0400H\u003c\/strong\u003e Modicon X80 ruggedized rack, provides four X-bus and Ethernet module slots with an integrated Ethernet backplane for Modicon M340, M580, and X80 architectures. The backplane provides electrical module interconnection, XBE expansion connectivity, and 24 VDC \/ 3.3 VDC power distribution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMEXBP0400H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModicon X80 ruggedized rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Type\u003c\/td\u003e\n\u003ctd\u003eDual X-bus and Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Slots\u003c\/td\u003e\n\u003ctd\u003e4 X-bus + Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Modules\u003c\/td\u003e\n\u003ctd\u003eBMXCPS power supply, I\/O modules, specific application modules, BMX processors, BME processors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Connection\u003c\/td\u003e\n\u003ctd\u003e1 XBE connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.8 W at 24 VDC; 162 mW at 3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e118 mA at 24 VDC; 49 mA at 3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixing\u003c\/td\u003e\n\u003ctd\u003e4 screws, 4.32-6.35 mm panel holes; 4 M6 screws; 35 mm symmetrical DIN rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% without condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.705 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, RCM, EAC, Merchant Navy, ATEX Zone 2\/22, IECEx Zone 2\/22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2, IEC 61010-2-201, UL 61010-2-201, CSA C22.2 No 61010-2-201, IACS E10, IEC 61000-6-5, IEC 61850-3, IEC 60079-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Resistance\u003c\/td\u003e\n\u003ctd\u003eGas, dust, sand, salt, mold, and fungal-spore resistant classifications specified by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e1,588,025 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3595864173948\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModicon X80 Backplane and I\/O Bus Characteristics\u003c\/h3\u003e\n\u003cp\u003eBMEXBP0400H provides four X-bus and Ethernet positions for Modicon X80 modules. The dual-bus arrangement supports module communication and Ethernet connectivity within the rack. The XBE connector provides the electrical interface for rack expansion.\u003c\/p\u003e\n\u003cp\u003eThe backplane accepts Modicon X80 I\/O modules, application modules, BMX processors, and BME processors. It can also be combined with compatible X80 power supply arrangements. Its conformal-coated construction and specified gas, dust, sand, salt, and fungal resistance support installation in the environmental classes stated by the manufacturer.\u003c\/p\u003e\n\u003cp\u003eThe rack can be mounted using panel screws, M6 plate screws, or clips on a 35 mm symmetrical DIN rail. Most I\/O modules support hot swapping when the complete system configuration and module type permit this operation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What electrical supply characteristics are specified for BMEXBP0400H?\u003cbr\u003eA: The backplane has a specified current consumption of 118 mA at 24 VDC and 49 mA at 3.3 VDC, corresponding to the stated 24 VDC and 3.3 VDC power consumption values.\u003c\/p\u003e\n\u003cp\u003eQ: How many module positions are provided?\u003cbr\u003eA: The rack provides 4 X-bus and Ethernet slots for compatible Modicon X80 modules.\u003c\/p\u003e\n\u003cp\u003eQ: Can BMEXBP0400H be mounted on a DIN rail?\u003cbr\u003eA: Yes. The specified fixing method includes clips for a 35 mm symmetrical DIN rail, in addition to panel and plate screw mounting.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the backplane on a mechanically stable panel or 35 mm symmetrical DIN rail and secure it according to the specified mounting method. Verify that the rack, power supply, processor, and installed X80 modules are mechanically compatible before energizing the system.\u003c\/p\u003e\n\u003cp\u003eMaintain correct module orientation and ensure each module is fully seated in its backplane position. Route power and communication wiring separately where practical to reduce electromagnetic coupling. Follow the applicable grounding and shielding requirements for the complete Modicon installation.\u003c\/p\u003e\n\u003cp\u003eFor rack expansion, connect the XBE interface only with compatible X80 expansion hardware. Before servicing or replacing modules, verify whether the installed module supports hot swapping and follow the applicable Schneider Electric installation procedure.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52998363611421,"sku":"BMEXBP0400H","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMEXBP0400H2.jpg?v=1789956886","url":"https:\/\/www.6gcontrols.com\/hu\/products\/schneider-electric-bmexbp0400h-modicon-x80-ruggedized-rack","provider":"6G Controls","version":"1.0","type":"link"}