{"product_id":"schneider-electric-bmxart0414-modicon-x80-analog-isolated-low-level-input-module","title":"Schneider Electric BMXART0414 Modicon X80 Analog Isolated Low Level Input Module","description":"\u003cp\u003eConfigured for isolated low-level analog signal acquisition in the Modicon X80 platform, the \u003cstrong\u003eSchneider Electric BMXART0414\u003c\/strong\u003e (\u003cstrong\u003eBMXART0414\u003c\/strong\u003e Analog Input Module) provides four isolated input channels with configurable voltage, resistance, temperature probe, and thermocouple measurement functions. The module uses a 40-way connector and occupies one rack slot.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXART0414\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog isolated low level input module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Level\u003c\/td\u003e\n\u003ctd\u003eLow level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Isolation\u003c\/td\u003e\n\u003ctd\u003eIsolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e40-way, 1 connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Type\u003c\/td\u003e\n\u003ctd\u003eVoltage, resistance, temperature probe, thermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Ranges\u003c\/td\u003e\n\u003ctd\u003e+\/- 40 mV, +\/- 80 mV, +\/- 160 mV, +\/- 320 mV, +\/- 640 mV, +\/- 1.28 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Inputs\u003c\/td\u003e\n\u003ctd\u003e400 Ohm and 4000 Ohm, 2-wire, 3-wire, or 4-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog\/Digital Conversion\u003c\/td\u003e\n\u003ctd\u003eSigma delta, 16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Resolution\u003c\/td\u003e\n\u003ctd\u003e15 bits + sign\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e120 dB at 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDifferential Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e60 dB at 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold Junction Compensation\u003c\/td\u003e\n\u003ctd\u003eExternal by Pt100 probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Filtering\u003c\/td\u003e\n\u003ctd\u003eFirst order digital filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Read Cycle\u003c\/td\u003e\n\u003ctd\u003e400 ms with temperature probe; 200 ms with thermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1400 V DC between channels and bus; 750 V DC between channels; 750 V DC between channels and ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Wiring Resistance\u003c\/td\u003e\n\u003ctd\u003eUp to 500 Ohm depending on sensor type and wiring configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 deg C for supported temperature probe and thermocouple configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecalibration\u003c\/td\u003e\n\u003ctd\u003eInternal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indication\u003c\/td\u003e\n\u003ctd\u003eRUN, channel diagnostic, ERR, and I\/O LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.135 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% at 55 deg C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e3 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e30 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e150 mA at 3.3 VDC; 40 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLatest Firmware\u003c\/td\u003e\n\u003ctd\u003eSV2.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eEAC, RCM, UL, Merchant Navy, CSA, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2, IEC 61000-6-4, IEC 61000-6-2, EN 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and I\/O Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe BMXART0414 provides four independently isolated analog acquisition channels within one Modicon X80 rack slot. Its low-level ranges extend from +\/- 40 mV to +\/- 1.28 V, while resistance and temperature configurations support multiple 2-wire, 3-wire, and 4-wire sensor arrangements. The module performs 16-bit sigma-delta conversion with a stated analog resolution of 15 bits plus sign.\u003c\/p\u003e\n\u003cp\u003eChannel and bus isolation are specified at 1400 V DC, while channel-to-channel and channel-to-ground isolation are specified at 750 V DC. Common-mode rejection is 120 dB at 50\/60 Hz and differential-mode rejection is 60 dB at 50\/60 Hz.\u003c\/p\u003e\n\u003cp\u003eThe module supports internal recalibration and first-order digital filtering. Temperature and thermocouple configurations use external Pt100-based cold junction compensation where specified. The source lists SV2.3 as the latest firmware version for the product.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many analog channels does the BMXART0414 provide?\u003c\/p\u003e\n\u003cp\u003eA: The module provides four isolated low-level analog input channels.\u003c\/p\u003e\n\u003cp\u003eQ: What signal types can be connected to the BMXART0414?\u003c\/p\u003e\n\u003cp\u003eA: Depending on configuration, the inputs support low-level voltage, 400 Ohm and 4000 Ohm resistance, temperature probes, and thermocouples.\u003c\/p\u003e\n\u003cp\u003eQ: What is the specified module power consumption?\u003c\/p\u003e\n\u003cp\u003eA: The source specifies 150 mA at 3.3 VDC and 40 mA at 24 VDC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the BMXART0414 in its designated Modicon X80 rack slot and connect the field wiring through the specified 40-way connector. Confirm the configured input type before wiring each channel because voltage, resistance, temperature probe, and thermocouple configurations use different electrical measurement arrangements.\u003c\/p\u003e\n\u003cp\u003eFor low-level analog signals, route sensor wiring separately from high-current power conductors and switching circuits. Maintain appropriate shielding and grounding practices for the installation environment. Use the specified wiring configuration for 2-wire, 3-wire, or 4-wire resistance and temperature sensors.\u003c\/p\u003e\n\u003cp\u003eVerify the selected input range against the connected sensor before commissioning. For thermocouple and temperature measurements, confirm the external Pt100 cold junction compensation arrangement where applicable. Check RUN, channel diagnostic, ERR, and I\/O status indicators during startup. The module has IP20 protection and an operating temperature range of 0 to 60 deg C.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52998981517597,"sku":"BMXART0414","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXART04142.jpg?v=1789969586","url":"https:\/\/www.6gcontrols.com\/hu\/products\/schneider-electric-bmxart0414-modicon-x80-analog-isolated-low-level-input-module","provider":"6G Controls","version":"1.0","type":"link"}