{"product_id":"schneider-bmxcps4022s-modicon-x80-safety-power-supply-module","title":"Schneider BMXCPS4022S Modicon X80 Safety Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eBMXCPS4022S\u003c\/strong\u003e is a Schneider Electric Modicon X80 safety power supply module designed for redundant power architectures in industrial automation systems. It accepts a 24-48 VDC primary supply and provides separate 24 VDC and 3.3 VDC secondary outputs for X80 I\/O module logic and processor power. Network-based diagnostics provide information on redundancy status, operating time and remaining service life.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply Function and Redundant Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXCPS4022S supplies the internal power rails required by Modicon X80 system modules. Its two secondary supply outputs serve different electrical loads: the 24 VDC output supplies the I\/O module power circuit, while the 3.3 VDC output supplies I\/O module logic and processor circuitry.\u003c\/p\u003e\n\u003cp\u003eThe module supports redundant power architectures. Its diagnostic functions include redundancy testing and monitoring of remaining operating life, temperature and operating time. These functions provide maintenance information for assessing the power supply condition and planning replacement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Protection and Status Monitoring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe secondary circuits incorporate overload, overvoltage and short-circuit protection. These protections address abnormal conditions on the module's output side; they should not be interpreted as a substitute for external protection of the primary supply circuit.\u003c\/p\u003e\n\u003cp\u003eThree green LED indicators provide local status information:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage OK: indicates that the required voltages are present.\u003c\/li\u003e\n\u003cli\u003eRedundancy OK: indicates the redundancy status.\u003c\/li\u003e\n\u003cli\u003ePower supply status: indicates the module's power supply condition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA RESET button supports a cold restart. The module also provides an alarm relay connection for external status signalling.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe output power allocation must be considered when calculating the rack power budget. The 40 W rating on the 24 VDC rail applies when the 3.3 VDC output is not loaded; the available power on both rails must remain within the module's total power capacity.\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXCPS4022S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSafety Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Voltage\u003c\/td\u003e\n\u003ctd\u003e24-48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Voltage Limit\u003c\/td\u003e\n\u003ctd\u003e18-62.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Circuit\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e1.9 A at 24 V; 1 A at 48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e60 A at 24 V; 60 A at 48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Output 1\u003c\/td\u003e\n\u003ctd\u003e3.3 VDC, 18 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Output 2\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 40 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Current\u003c\/td\u003e\n\u003ctd\u003e5 A at 3.3 VDC; 1.67 A at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e8.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e721,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eInternal, inaccessible fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eOverload, overvoltage and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e5-pin power supply connector and protective earth; 2-pin alarm relay connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset Function\u003c\/td\u003e\n\u003ctd\u003eCold-start RESET pushbutton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1,500 V primary\/ground; 1,500 V primary\/secondary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 100 MOhm primary\/ground; \u0026gt;= 100 MOhm primary\/secondary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Interruption Immunity\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 60 deg C (source discrepancy; see editorial note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% at 55 deg C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0-2,000 m; derating required from 2,000 to 5,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e3 Gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e15 Gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.81 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, RCM, EAC, ATEX Zone 2\/22, IECEx Zone 2\/22, TÜV, Marine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2, IEC 61010-2-201, UL 61010-2-201, CSA C22.2 No. 61010-2-201, IACS E10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e3606489562496\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Electrical Connections\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXCPS4022S is designed for installation in a Modicon X80 module rack. It occupies the dedicated power supply position marked CPS and is secured to the rack using two screws.\u003c\/p\u003e\n\u003cp\u003eThe package includes two removable caged terminal blocks: one 5-way connector for the DC supply and protective earth, and one 2-way connector for the alarm relay. The module has an IP20 enclosure rating and is intended for installation inside a suitable equipment enclosure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Certification Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module has a conformal protective coating and specified resistance to gas, dust, sand, salt and mould-related environmental conditions. Its environmental classifications include gas resistance class Gx under ISA S71.04, class 3C4 under IEC 60721-3-3, and dust and sand resistance class 3S4.\u003c\/p\u003e\n\u003cp\u003eThe listed hazardous-location classifications include Class I Division 2, ATEX Zone 2\/22 and IECEx Zone 2\/22. Actual installation approval must be checked against the applicable certificate, equipment configuration and site requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the BMXCPS4022S operate in a redundant power supply configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. It is designed for redundant power architectures and provides redundancy diagnostics, including redundancy testing and status monitoring. The system configuration must account for the power requirements of both supply modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 3.3 VDC and 24 VDC outputs deliver their maximum rated power simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The output ratings must be evaluated against the total available power budget. The 40 W rating on the 24 VDC output applies when the 3.3 VDC output is not loaded. Do not calculate the two output ratings as independent power capacities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the RESET button do on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The RESET button initiates a cold restart of the rack. This reinitializes the rack modules and, when installed in the main local rack, also reinitializes the CPU. The operation can cause I\/O modules to transition to their initialized state, so its use should be coordinated with the control system operating procedure.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68096383779101,"sku":"BMXCPS4022S","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXCPS4022S2.jpg?v=1794823883","url":"https:\/\/www.6gcontrols.com\/id\/products\/schneider-bmxcps4022s-modicon-x80-safety-power-supply-module","provider":"6G Controls","version":"1.0","type":"link"}