The Schneider Electric BMXAMM0600, also cataloged as the BMXAMM0600 Mixed Analog I/O Module, provides four non-isolated analog inputs and two non-isolated analog outputs for voltage and current signal acquisition and generation within the Modicon X80 platform. It occupies one rack slot and uses a 20-way connector.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | BMXAMM0600 |
| Brand | Schneider Electric |
| Series | Modicon X80 |
| Product Type | Mixed Analog I/O Module |
| Analog Inputs | 4 |
| Analog Outputs | 2 |
| Input Signals | 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, 0-10 V, +/-10 V |
| Output Signals | 0-20 mA, 4-20 mA, +/-10 V |
| Input Resolution | 12 bits to 14 bits, depending on range |
| Output Resolution | 11 bits for current ranges; 12 bits for +/-10 V |
| Input Impedance | 250 Ohm |
| Input Isolation | Non-isolated between channels |
| Crosstalk Attenuation | Minimum 70 dB |
| Common Mode Rejection | 80 dB |
| Isolation Voltage | 1400 V DC channel-to-ground; 1400 V DC channel-to-bus; 750 V DC between I/O groups |
| Fast Read Cycle | 1 ms + 1 ms x number of channels used |
| Nominal Read Cycle | 5 ms for 4 channels |
| Output Conversion Time | <= 2 ms |
| Connection | 20-way, 1 connector |
| Power Consumption | 2.6 W typical, 3.2 W maximum at 24 V DC; 0.35 W typical, 0.48 W maximum at 3.3 V DC |
| Current Consumption | 240 mA at 3.3 V DC |
| Operating Temp | 0 to 60 deg C |
| Storage Temp | -40 to 85 deg C |
| Relative Humidity | 5-95% at 55 deg C, non-condensing |
| IP Rating | IP20 |
| Vibration Resistance | 3 gn |
| Shock Resistance | 30 gn |
| Weight | 0.155 kg |
| Dimensions | 5.5 cm x 11.0 cm x 11.6 cm |
| Origin | US |
| Certifications | CE, RCM, CSA, EAC, Merchant Navy, UL |
| Standards | IEC 61010-2-201, IEC 61131-2, UL 61010-2-201, CSA C22.2 No 61010-2-201 |
| Firmware | SV01.50 listed in supplied product data |
Analog Signal Integrity and I/O Conversion
The BMXAMM0600 uses separate configurable voltage and current ranges for its four analog inputs and two analog outputs. Input conversion supports 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, 0-10 V, and +/-10 V. Output conversion supports 0-20 mA, 4-20 mA, and +/-10 V.
The input channels use firmware-based first-order digital filtering. The specified minimum crosstalk attenuation is 70 dB, with 80 dB common mode rejection. Input measurement error varies with signal range and temperature, with supplied specifications ranging from 0.25% to 0.5% of full scale for current inputs and up to 0.35% of full scale for voltage inputs under the stated conditions.
The module provides fallback operation through predefined or configurable behavior. Status indication includes RUN, channel diagnostic, ERR, and I/O LEDs.
Frequently Asked Questions
Q: Are the four analog input channels galvanically isolated from each other?
A: No. The analog inputs are specified as non-isolated between channels. The module nevertheless specifies 1400 V DC isolation between channels and ground and between channels and the bus, plus 750 V DC between groups of I/O channels.
Q: What signal ranges can the analog inputs accept?
A: Each input can be configured for 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, 0-10 V, or +/-10 V operation.
Q: What is the specified power consumption?
A: Consumption is 2.6 W typical and 3.2 W maximum at 24 V DC, with an additional 0.35 W typical and 0.48 W maximum at 3.3 V DC.
Field Installation Guidelines
- Install the module in a compatible Modicon X80 rack and secure the module according to the rack installation procedure.
- Use the specified 20-way connector and verify terminal assignments before applying field signals.
- Keep analog signal wiring separated from high-current switching, motor, and power wiring where practical.
- Connect cable shields according to the plant grounding scheme and the applicable Modicon X80 installation requirements.
- Verify the configured input or output range against the connected field instrument before energizing the channel.
- Do not exceed the specified input overload limits or output maximum conversion values.
- Check RUN, ERR, I/O, and channel diagnostic LEDs after startup.
- Maintain the specified 0 to 60 deg C operating environment and IP20 enclosure conditions.
- Verify signal polarity and current-loop wiring before commissioning voltage or current channels.
Pembayaran: T/T, Western Union.
Pelabuhan pengiriman: Xiamen.
Waktu produksi: Biasanya 1–3 hari kerja setelah pembayaran dikonfirmasi (tergantung ketersediaan stok).
Pengiriman ke seluruh dunia: Kami mengirimkan komponen otomasi industri kepada pelanggan di seluruh dunia. Biaya pengiriman akan dicantumkan dalam RFQ Anda.
F.A.Q.
Pertanyaan umum tentang penawaran harga, pengiriman, garansi, dan pengembalian barangKlik Minta Penawaran di halaman produk dan kirimkan nomor komponen, jumlah yang diperlukan, serta negara tujuan kepada kami. Tim penjualan kami akan membalas dengan informasi ketersediaan terkini, harga, dan perkiraan waktu pengiriman.
Barang yang tersedia biasanya disiapkan setelah pembayaran dan konfirmasi pesanan. Sebagian besar pesanan dikirim dari gudang kami di Tiongkok, meskipun lokasi pengiriman dapat berbeda tergantung ketersediaan stok saat ini.
Ya. Kami mengirimkan suku cadang otomasi industri kepada pelanggan di seluruh dunia. Biaya pengiriman dan waktu transit bergantung pada tujuan, berat paket, ukuran produk, serta persyaratan impor setempat.
Kami biasanya menggunakan DHL, FedEx, UPS, dan layanan kurir internasional lainnya. Jasa pengiriman dapat dipilih sesuai dengan tujuan, kecepatan pengiriman, ukuran kiriman, dan kebutuhan pelanggan.
Produk kami umumnya dilindungi oleh garansi 12 bulan. Produk yang memenuhi syarat juga dapat dikembalikan berdasarkan kebijakan pengembalian dana 30 hari kami. Harap hubungi tim kami sebelum mengembalikan barang apa pun untuk mengonfirmasi ketentuan yang berlaku dan petunjuk pengembalian.
Anda mungkin juga menyukai
Pos Blog
Berita otomasi industri, panduan teknis, dan pembaruan produk.