Vai alle informazioni sul prodotto
1 di 3

ICS Triplex T8451 Trusted TMR Digital Output Module

18 disponibili
  • Manufacturer: ICS Triplex
  • Product No.: T8451
  • Country of origin: USA
  • Product Type: Trusted TMR Digital Output Module
  • Condition: Completamente nuovo
  • Payment: Bonifico telegrafico, Western Union
  • Weight: 1.13 kg
  • Dimensions: 241 x 51 x 181 mm
  • Shipping port: Xiamen
  • Warranty: 12 mesi
  • Descrizione
  • Reviews
  • Spedizione e pagamento

ICS Triplex T8451 Trusted TMR Digital Output Module

The ICS Triplex T8451, also cataloged as the T8451 Digital Output Module, operates as a dedicated hardware component for safety-critical digital load switching within Trusted TMR Safety Instrumented Systems. The module delivers 40 independent discrete channels engineered for continuous state monitoring and deterministic voting execution. Internal voting circuits process commands across triplicated processor buses to maintain systemic control integrity without operational interruption.

Hardware Specifications

Parameter Specification
Model T8451
Brand ICS Triplex
Physical Form Factor Chassis-mounted module (T8100/T8300 slot compatible)
Dimensions 241 x 51 x 181 mm
Weight 1.13 kg
Operating Temp -40 to +70 deg C
Storage Temp -40 to +85 deg C
Relative Humidity 5 to 95% non-condensing
Operating Voltage 18 to 32 VDC
Output Density 40 independent channels
Continuous Current 2 A per channel, 8 A per group
Galvanic Isolation 2500 VDC channel-to-backplane
Response Time 0.5 ms turn-on/turn-off delay
Safety Rating TÜV IEC 61508 SIL 3
Power Consumption 12 W internal backplane power dissipation
MTBF 1,100,000 hours (Telcordia SR-332, 25 deg C)

Triple Modular Redundancy and Isolation Architecture

The hardware architecture incorporates a triple modular redundancy (TMR) 2oo3 voting structure across all 40 digital channels to achieve SIL 3 certification compliance. Output driver circuits perform continuous line monitoring and stuck-output fault detection to isolate channel degradation prior to system-level trips. Integrated 2500 VDC galvanic isolation isolates field-side transient electrical spikes from reaching internal backplane logic arrays. Upon detecting internal fault states, the module executes fail-safe state execution, driving designated channels to a predetermined de-energized or energized state within 0.5 ms. Sequence of Events (SOE) timestamping records channel state transitions at a 1 ms sampling resolution.

Frequently Asked Questions

Q: Does the chassis interface support online module replacement without shutting down the system?

A: Yes. The chassis locking mechanism permits tool-less hot-swap operations under power. When inserted into an active slot, the system syncs channel configuration parameters and operational memory without altering active field output states.

Q: How does the module handle a single fault condition within one of its triplicated channels?

A: The internal 2oo3 voting architecture allows two healthy hardware channels to override a faulty channel path. Fault status reports transmit to the main processor via the backplane bus while the field device maintains uninterrupted operation.

Q: What are the primary grounding requirements for the 2500 VDC galvanic isolation barrier?

A: Channel isolation requires distinct separation between field supply 0 V VDC references and backplane logic ground paths. Shield terminations must tie directly to chassis ground at the enclosure entry point.

Field Installation Guidelines

  1. Ensure the field wiring harness is disconnected or de-energized prior to inserting the module into the T8100 or T8300 chassis slot.
  2. Align the top and bottom circuit board guides with the target chassis slot and slide the unit inward until the backplane connectors seat firmly.
  3. Engage the mechanical front-panel locking latches to secure electrical contact with the backplane bus.
  4. Connect field cabling using screened, twisted-pair cables rated for a minimum of 300 V isolation and operating temperatures up to 85 deg C.
  5. Verify field power supply levels fall within the 18 to 32 VDC window at the terminal block prior to enabling output loads.
  6. Terminate cable shields at the dedicated enclosure earth busbar using a low-impedance clamp; do not daisy-chain shield wires across channels.

Pagamento: T/T, Western Union.

Porto di spedizione: Xiamen.

Tempi di consegna: In genere 1–3 giorni lavorativi dopo la conferma del pagamento (in base alla disponibilità).

Consegna in tutto il mondo: Spediamo componenti per l’automazione industriale a clienti di tutto il mondo. Il costo del trasporto viene indicato nel preventivo relativo alla vostra richiesta.

Domande frequenti (FAQ)

Domande frequenti su preventivi, spedizione, garanzia e resi

Fai clic su Richiedi un preventivo nella pagina del prodotto e inviaci il codice prodotto, la quantità richiesta e il Paese di destinazione. Il nostro team commerciale ti risponderà indicando la disponibilità attuale, il prezzo e i tempi di consegna stimati.

Gli articoli disponibili vengono normalmente preparati dopo il pagamento e la conferma dell’ordine. La maggior parte degli ordini viene spedita dal nostro magazzino in Cina, anche se il luogo di spedizione può variare in base alle scorte disponibili.

Sì. Spediamo componenti per l’automazione industriale a clienti in tutto il mondo. Il costo e i tempi di spedizione dipendono dalla destinazione, dal peso del pacco, dalle dimensioni del prodotto e dai requisiti locali per l’importazione.

Utilizziamo comunemente i servizi di corriere internazionali DHL, FedEx, UPS e altri. Il corriere può essere scelto in base alla destinazione, alla velocità di consegna, alle dimensioni della spedizione e alle esigenze del cliente.

I nostri prodotti sono generalmente coperti da una garanzia di 12 mesi. I prodotti idonei possono inoltre essere restituiti ai sensi della nostra politica di rimborso entro 30 giorni. Contatta il nostro team prima di restituire qualsiasi articolo per confermare i termini applicabili e le istruzioni per la restituzione.

Products FAQs

Potrebbe piacerti anche