{"product_id":"abb-tu812v1-3bse013232r1-compact-i-o-connection-unit","title":"ABB TU812V1 Unit Penamatan Modul Padat baharu dan penghantaran pertama","description":"\u003cp\u003eThe \u003cstrong\u003eABB TU812V1 (3BSE013232R1)\u003c\/strong\u003e is a compact I\/O connection unit designed to interface field process signals with compatible ABB I\/O modules. It provides a 25-pin male D-sub process connector supporting up to 16 I\/O signals. The unit supports single I\/O configurations, with a maximum current of 2 A per channel and 5 A at the process connection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTU812V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE013232R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCompact I\/O Connection Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eCompact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connection\u003c\/td\u003e\n\u003ctd\u003e25-pin male D-sub connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003e25-pin D-sub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per I\/O Channel\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current at Process Connection\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd\u003eHorizontal or vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e55 deg C horizontal; 40 deg C vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature for Approvals\u003c\/td\u003e\n\u003ctd\u003e+5 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20, IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e2, IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04 G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Class\u003c\/td\u003e\n\u003ctd\u003eClass I, IEC 61140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Conditions\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4, EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location Approvals\u003c\/td\u003e\n\u003ctd\u003eClass I Division 2 cULus, Class I Zone 2 cULus, ATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certifications\u003c\/td\u003e\n\u003ctd\u003eABS, BV, DNV, LR, CCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Marking\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eEN 50581:2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Compliance\u003c\/td\u003e\n\u003ctd\u003eDirective 2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e64 mm including connector; 58.5 mm edge-to-edge when installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e64 mm including terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e170 mm including latch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eProcess Signal Connections\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe TU812V1 provides a 25-pin male D-sub interface for connecting up to 16 I\/O signals. Its compact connection arrangement allows multiple process signals to be routed through a single connector rather than individual field wiring connections at the interface.\u003c\/p\u003e\n\u003cp\u003eThe maximum current rating is 2 A per I\/O channel, while the process connection has a separate maximum current rating of 5 A. Both limits should be considered when checking the connected circuit loads. The 50 V voltage rating and 500 V AC dielectric test voltage represent different electrical characteristics and should not be treated as interchangeable operating ratings.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatible ABB I\/O Modules\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe specified compatible I\/O modules include the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Input:\u003c\/strong\u003e AI810, AI815, AI820, AI830, AI830A, AI835, AI835A, AI845.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output:\u003c\/strong\u003e AO810, AO810V2, AO815, AO820, AO845, AO845A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Input:\u003c\/strong\u003e DI810, DI811, DI814, DI830, DI831, DI840, DI880, DI885.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Output:\u003c\/strong\u003e DO810, DO814, DO840, DO880.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOther I\/O Modules:\u003c\/strong\u003e DP820, DP840.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe connection unit supports single I\/O configurations. Module selection should be based on the required signal type, channel configuration and electrical characteristics of the connected field circuits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMounting and Environmental Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe TU812V1 supports both horizontal and vertical mounting. The maximum ambient temperature depends on the installation orientation: 55 deg C for horizontal mounting and 40 deg C for vertical mounting. This distinction should be considered when planning cabinet layouts and checking the thermal conditions around the installed equipment.\u003c\/p\u003e\n\u003cp\u003eThe IP20 enclosure rating indicates protection against access to hazardous parts by fingers and against solid foreign objects of 12.5 mm or larger. It does not provide protection against water ingress. The specified humidity range is 5 to 95%, non-condensing, with G3 corrosion protection according to ISA-S71.04.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many I\/O signals can the ABB TU812V1 support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The TU812V1 supports up to 16 I\/O signals through its 25-pin male D-sub process connector. The maximum current is 2 A per channel, subject to the overall 5 A process connection limit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which ABB I\/O modules are compatible with the TU812V1?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified compatible modules include AI810, AI815, AI820, AI830, AI830A, AI835, AI835A, AI845, AO810, AO810V2, AO815, AO820, AO845, AO845A, DI810, DI811, DI814, DI830, DI831, DI840, DI880, DI885, DO810, DO814, DO840, DO880, DP820 and DP840.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the TU812V1 be installed vertically?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The unit supports both horizontal and vertical mounting. However, the maximum ambient temperature is reduced from 55 deg C in horizontal mounting to 40 deg C in vertical mounting.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52750539686173,"sku":"TU812V1 3BSE013232R1","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/TU812V1_1000.jpg?v=1787112245","url":"https:\/\/www.6gcontrols.com\/ms\/products\/abb-tu812v1-3bse013232r1-compact-i-o-connection-unit","provider":"6G Controls","version":"1.0","type":"link"}