{"product_id":"schneider-bmxcps4022-modicon-x80-redundant-power-supply-module","title":"Schneider BMXCPS4022 Modicon X80 Redundant Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMXCPS4022\u003c\/strong\u003e is a Modicon X80 power supply module designed for 24-48 VDC input and redundant power supply architectures. It provides separate 3.3 VDC and 24 VDC secondary outputs for I\/O module logic and rack power requirements. The module includes secondary-circuit overload, overvoltage and short-circuit protection, network-accessible diagnostic functions, and dedicated redundancy status monitoring.\u003c\/p\u003e\n\u003ch3\u003ePower Supply Function and Redundancy\u003c\/h3\u003e\n\u003cp\u003eThe BMXCPS4022 converts the DC primary supply into the secondary voltages required by the Modicon X80 rack. Its output configuration supports both I\/O module logic and the 24 VDC supply requirements of the I\/O modules and processor.\u003c\/p\u003e\n\u003cp\u003eThe module supports redundant power supply architectures. Its diagnostic functions include redundancy testing, temperature monitoring, operating time and remaining operating time. These functions provide maintenance personnel with information about the power supply condition and redundancy status.\u003c\/p\u003e\n\u003ch3\u003eSecondary Output Configuration\u003c\/h3\u003e\n\u003cp\u003eThe power supply provides two secondary output circuits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3.3 VDC output:\u003c\/strong\u003e 5.5 A, with an 18 W secondary power rating for I\/O module logic at 0 to 60 deg C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 VDC output:\u003c\/strong\u003e 1.67 A, with a 40 W secondary power rating for I\/O module power supply and processor operation at 3.3 V without load, at 0 to 60 deg C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe secondary circuits incorporate overload, overvoltage and short-circuit protection. Maximum power dissipation is 8.5 W. These output ratings should be considered when checking the total rack power requirements and the connected module configuration.\u003c\/p\u003e\n\u003ch3\u003eElectrical Characteristics and Protection\u003c\/h3\u003e\n\u003cp\u003eThe specified primary input range is 24-48 VDC, with an allowable primary voltage range of 18-62.4 VDC. Input current is 1.9 A at 24 V and 1 A at 48 V. The specified inrush current is 60 A at both input voltages, with corresponding I2t values of 0.4 A2.s at 24 V and 1.9 A2.s at 48 V.\u003c\/p\u003e\n\u003cp\u003ePrimary-circuit protection is internal and not accessible. The module also provides primary-to-ground and primary-to-secondary insulation resistance of at least 100 Mohm, with a dielectric strength of 1500 V for both insulation paths.\u003c\/p\u003e\n\u003ch3\u003eIndicators and Electrical Connections\u003c\/h3\u003e\n\u003cp\u003eThree green LED indicators provide operating information:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage presence (OK).\u003c\/li\u003e\n\u003cli\u003eRedundancy OK.\u003c\/li\u003e\n\u003cli\u003ePower supply status.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA RESET push button provides a cold-start reset function. Electrical connections consist of one 5-pin connector for the power supply and protective earth, and one 2-pin connector for the alarm relay. Two removable terminal blocks, with 5-way and 2-way connections, are included.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Environmental Conditions\u003c\/h3\u003e\n\u003cp\u003eThe BMXCPS4022 is designed for installation in a Modicon X80 module rack and is secured with two screws. It has an IP20 protection rating and an operating temperature range of 0 to 60 deg C. The specified storage temperature range is -40 to 85 deg C.\u003c\/p\u003e\n\u003cp\u003eThe module supports relative humidity of 10-95%, without condensation. Its environmental specifications include 3C3 and 3C4 classifications according to IEC 60721-3-3. The specified immunity to interruptions is 1 ms.\u003c\/p\u003e\n\u003ch3\u003eParameter | Specification\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXCPS4022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRedundant DC Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24-48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18-62.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e1.9 A at 24 V; 1 A at 48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e60 A at 24 V and 48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI2t at Switch-On\u003c\/td\u003e\n\u003ctd\u003e0.4 A2.s at 24 V; 1.9 A2.s at 48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Output 1\u003c\/td\u003e\n\u003ctd\u003e3.3 VDC, 5.5 A, 18 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Output 2\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 1.67 A, 40 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature for Rated Output\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e8.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Functions\u003c\/td\u003e\n\u003ctd\u003eRedundancy test, temperature sensor, operating time and remaining operating time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eSecondary overload, overvoltage and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e3 green LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset Function\u003c\/td\u003e\n\u003ctd\u003eCold-start RESET button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Connection\u003c\/td\u003e\n\u003ctd\u003e1 x 2-pin connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Connection\u003c\/td\u003e\n\u003ctd\u003e1 x 5-pin connector, including protective earth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 100 Mohm, primary\/ground and primary\/secondary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1500 V, primary\/ground and primary\/secondary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterruption Immunity\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Distance Between Devices\u003c\/td\u003e\n\u003ctd\u003e10 m \/ 15 m (connection-dependent values)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e752,000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eModicon X80 module rack, secured with 2 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Compatibility\u003c\/td\u003e\n\u003ctd\u003eAll module racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Classification\u003c\/td\u003e\n\u003ctd\u003e3C3 and 3C4 according to IEC 60721-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10-95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN 61131-2, EN 61000-6-4, EN 61000-6-2, EN 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Directives\u003c\/td\u003e\n\u003ctd\u003e2014\/35\/EU, 2014\/30\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.81 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e3606481179074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Carbon Footprint\u003c\/td\u003e\n\u003ctd\u003e496 kg CO2 eq.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the BMXCPS4022 be used in a redundant power supply architecture?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The BMXCPS4022 is designed for redundant power supply architectures. It includes redundancy monitoring and a dedicated green redundancy status LED. The actual redundant arrangement must follow the applicable Modicon X80 system configuration requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the 3.3 VDC and 24 VDC outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 3.3 VDC output supplies I\/O module logic, while the 24 VDC output supplies the I\/O module power circuit and supports processor operation under the specified no-load condition. Both outputs have separate current and power ratings that must be considered when checking rack power consumption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What should be checked when replacing an existing BMXCPS4022?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Verify the complete model number, 24-48 VDC input supply, secondary output requirements, rack configuration and redundant power arrangement. Also check the connector configuration and the power demand of the installed modules before replacement.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68096211255581,"sku":"BMXCPS4022","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXCPS40222.jpg?v=1794823495","url":"https:\/\/www.6gcontrols.com\/ms\/products\/schneider-bmxcps4022-modicon-x80-redundant-power-supply-module","provider":"6G Controls","version":"1.0","type":"link"}