Configured for isolated analog signal acquisition in the Modicon X80 platform, the Schneider Electric BMXAMI0410H (BMXAMI0410H analog input module) provides four high-level input channels for current and voltage measurement. It supports 16-bit analog resolution, channel isolation, conformal coating, and direct connection through a 20-way connector.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | BMXAMI0410H |
| Brand | Schneider Electric |
| Series | Modicon X80 |
| Product Type | Analog input module |
| Input Channels | 4 |
| Input Type | Isolated high-level analog input |
| Current Input | +/- 20 mA, 0...20 mA, 4...20 mA |
| Voltage Input | +/- 10 V, +/- 5 V, 0...10 V, 0...5 V, 1...5 V |
| Analog Input Resolution | 16 bits |
| A/D Conversion | 24 bits |
| Measurement Resolution | 0.92 uA for current ranges; 0.35 mV for voltage ranges |
| Input Impedance | 10 MOhm voltage mode; 250 Ohm + 3.6...50 Ohm internal protective resistor current mode |
| Channel Isolation | 300 VDC between channels |
| Isolation to Ground | 1400 VDC |
| Isolation to Bus | 1400 VDC |
| Crosstalk Attenuation | Minimum 80 dB |
| Common Mode Rejection | 90 dB |
| Conversion Cycle | 1 ms + 1 ms x number of channels used, fast read |
| Nominal Read Cycle | 5 ms for 4 channels |
| Measurement Error | 0.15% of full scale for current inputs at 25 deg C; 0.075% of full scale for voltage inputs at 25 deg C |
| Maximum Operating Error | Up to 0.55% of full scale for current inputs and 0.2% of full scale for voltage inputs over -25...70 deg C |
| Power Consumption | 0.82 W typical / 1.30 W maximum at 24 VDC |
| Current Consumption | 45 mA at 24 VDC; 150 mA at 3.3 VDC |
| Electrical Connection | 20-way connector |
| Protective Treatment | Conformal coating |
| Protection Rating | IP20 |
| Operating Temp | -25...70 deg C |
| Storage Temp | -40...85 deg C |
| Relative Humidity | 5...95% at 55 deg C, non-condensing |
| Vibration Resistance | 3 gn |
| Shock Resistance | 30 gn |
| Weight | 0.143 kg |
| Origin | US |
| Certifications | CE, RCM, CSA, EAC, Merchant Navy, UL, ATEX, IEC-Ex |
| Standards | IEC 61010-2-201, IEC 61131-2, UL 61010-2-201, CSA C22.2 No 61010-2-201 |
Industrial Control and Analog Signal Integrity
The BMXAMI0410H uses isolated input channels to separate analog measurement circuits from each other and from the Modicon X80 bus. The module accepts both current and voltage signal ranges, allowing channel configuration for 4-20 mA, 0-20 mA, +/- 20 mA, 0-10 V, +/- 10 V, 0-5 V, +/- 5 V, and 1-5 V signals.
A minimum 80 dB crosstalk attenuation and 90 dB common mode rejection are specified for signal acquisition. The module uses first-order digital filtering and provides a digital value range of -32768 to +32767 in maximum user scale, with +/-10000 as the default scale.
The conformal-coated construction is specified for severe environments. Environmental characteristics include gas resistance class Gx and 3C4, dust and sand resistance class 3S4, salt resistance level 2, and mold and fungal-spore resistance class 3B2.
Frequently Asked Questions
Q: What signal types can the BMXAMI0410H measure?
A: The four channels support +/- 20 mA, 0...20 mA, 4...20 mA, +/- 10 V, +/- 5 V, 0...10 V, 0...5 V, and 1...5 V input ranges.
Q: Are the four analog channels electrically isolated?
A: Yes. The module specifies 300 VDC isolation between channels and 1400 VDC isolation between channels and ground and between channels and the bus.
Q: What is the maximum power consumption of the module?
A: The specified maximum consumption is 1.30 W at 24 VDC. The typical value is 0.82 W.
Field Installation Guidelines
- Install the module in a compatible Modicon X80 rack and connect it through the specified 20-way connector.
- Verify the configured input range against the actual field transmitter or voltage source before energizing the channel.
- Keep analog signal wiring separated from high-current power and switching conductors to reduce electromagnetic coupling.
- Use appropriate shield termination practices for the installed signal and cabinet grounding design.
- Confirm channel isolation requirements when connecting field devices with different reference potentials.
- Maintain the specified operating temperature and humidity limits inside the enclosure.
- Check the RUN, channel diagnostic, ERR, and I/O LEDs during commissioning.
- Do not apply input voltages or currents outside the documented overload and conversion limits.
Pembayaran: T/T, Western Union.
Pelabuhan penghantaran: Xiamen.
Tempoh penghantaran: Biasanya 1–3 hari bekerja selepas pengesahan pembayaran (tertakluk pada stok).
Penghantaran ke seluruh dunia: Kami menghantar alat ganti automasi industri kepada pelanggan di seluruh dunia. Kos penghantaran akan disebut harga bersama RFQ anda.
Soalan Lazim
Soalan lazim tentang sebut harga, penghantaran, waranti dan pemulanganKlik Minta Sebut Harga pada halaman produk dan hantar nombor bahagian, kuantiti yang diperlukan serta negara destinasi kepada kami. Pasukan jualan kami akan membalas dengan ketersediaan semasa, harga dan anggaran masa penghantaran.
Item dalam stok biasanya disediakan selepas pembayaran dan pengesahan pesanan. Kebanyakan pesanan dihantar dari gudang kami di China, walaupun lokasi penghantaran mungkin berbeza bergantung pada stok semasa.
Ya. Kami menghantar komponen automasi industri kepada pelanggan di seluruh dunia. Kos penghantaran dan masa transit bergantung pada destinasi, berat bungkusan, saiz produk dan keperluan import tempatan.
Kami biasanya menggunakan DHL, FedEx, UPS dan perkhidmatan kurier antarabangsa yang lain. Syarikat pengangkutan boleh dipilih berdasarkan destinasi, kelajuan penghantaran, saiz kiriman dan keperluan pelanggan.
Produk kami secara amnya dilindungi oleh waranti 12 bulan. Produk yang layak juga boleh dipulangkan di bawah polisi bayaran balik 30 hari kami. Sila hubungi pasukan kami sebelum memulangkan mana-mana item untuk mengesahkan terma yang berkenaan dan arahan pemulangan.
Anda mungkin juga suka
Siaran Blog
Berita automasi industri, panduan teknikal dan kemas kini produk.