{"product_id":"schneider-electric-bmxsdo0802-modicon-x80-safety-digital-output-module","title":"Schneider Electric BMXSDO0802 Modicon X80 Safety Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eBMXSDO0802\u003c\/strong\u003e is an 8-channel safety digital output module in the Schneider Electric Modicon X80 I\/O range, designed for Modicon M580 Safety controllers. It provides 24 VDC positive-logic semiconductor outputs for safety-related control signals. The module features non-isolated output channels, individual channel protection functions, and a 1.2 ms output response time.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXSDO0802 switches 24 VDC field loads through eight semiconductor output channels. Positive logic defines the output switching arrangement, while the electronic output stage provides overload, overvoltage, short-circuit, and reverse-polarity protection.\u003c\/p\u003e\n\u003cp\u003eThe module supports a maximum current of 0.625 A per channel and a maximum module current of 10 A. These ratings must be considered together when allocating field loads and designing the output circuit.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module is intended for use with a \u003cstrong\u003eModicon M580 Safety processor\u003c\/strong\u003e. It is part of the safety I\/O architecture rather than a general-purpose output module for unrestricted use with standard controllers.\u003c\/p\u003e\n\u003cp\u003eThe supplied product information identifies TÜV Rheinland certification for safety applications, with capability levels specified under IEC 61508\/61511, IEC 62061, ISO 13849, and railway safety standards. The applicable safety integrity or performance level depends on the system architecture, configuration, and application requirements; it should not be interpreted as an automatic SIL or performance-level rating for every installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Characteristics and Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe output response time is 1.2 ms. The maximum voltage drop in the ON state is less than 1.2 V, which should be considered when checking the voltage available at the connected field load.\u003c\/p\u003e\n\u003cp\u003eAdditional electrical characteristics include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput parallel connection: permitted, maximum 2 outputs.\u003c\/li\u003e\n\u003cli\u003eMinimum resistive load impedance: 48 Ohm.\u003c\/li\u003e\n\u003cli\u003eInsulation resistance: greater than 10 MOhm at 500 VDC.\u003c\/li\u003e\n\u003cli\u003eOutput voltage detection: below 14 VDC indicates a sensor fault; above 18 VDC indicates sensor OK.\u003c\/li\u003e\n\u003cli\u003eReverse-polarity protection: blocking diode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module also provides a switching-frequency specification of 0.5\/LI² Hz. This is retained as supplied; the exact interpretation should be checked against the manufacturer's technical documentation before using it to calculate switching limits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXSDO0802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSafety Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Platform\u003c\/td\u003e\n\u003ctd\u003eModicon M580 Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Technology\u003c\/td\u003e\n\u003ctd\u003eSemiconductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Logic\u003c\/td\u003e\n\u003ctd\u003ePositive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19-30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Channel\u003c\/td\u003e\n\u003ctd\u003e0.625 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Module Current\u003c\/td\u003e\n\u003ctd\u003e10 A (see editorial note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e1.2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum ON-State Voltage Drop\u003c\/td\u003e\n\u003ctd\u003eLess than 1.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Resistive Load\u003c\/td\u003e\n\u003ctd\u003e48 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Parallel Connection\u003c\/td\u003e\n\u003ctd\u003eYes, maximum 2 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd\u003e0.5\/LI2 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003eGreater than 10 MOhm at 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Detection Threshold\u003c\/td\u003e\n\u003ctd\u003eLess than 14 VDC: sensor fault; greater than 18 VDC: sensor OK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse Polarity Protection\u003c\/td\u003e\n\u003ctd\u003eBlocking diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther Protection\u003c\/td\u003e\n\u003ctd\u003eOverload, overvoltage and short circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1500 VAC, 50\/60 Hz, 1 minute, output\/ground and output\/internal logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61508, IEC 61511, IEC 62061, ISO 13849\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRailway Standards\u003c\/td\u003e\n\u003ctd\u003eEN 50126, EN 50128, EN 50129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eTÜV Rheinland, CE, UL, CSA, RCM, EAC, UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Coating\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% at 55 deg C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e383,000 hours (manufacturer listing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e32 x 131 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e3606481204929\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Carbon Footprint\u003c\/td\u003e\n\u003ctd\u003e206 kg CO2 eq.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eMounting and Connection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXSDO0802 is installed on a Modicon X80 module carrier and secured with two screws. It supports a 20-pin removable terminal block connection, with cage-clamp, screw-clamp or spring-clamp terminal block options identified in the supplied product information.\u003c\/p\u003e\n\u003cp\u003eThe module is taller than a standard Modicon X80 Ethernet or X-Bus rack module. Rack clearance and module positioning should therefore be checked before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the BMXSDO0802 operate with a standard Modicon M580 processor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. This is a safety output module intended for use with a Modicon M580 Safety processor. The safety controller and associated system configuration must support the module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can two output channels be connected in parallel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The manufacturer specifies parallel connection of up to two outputs. The connected load and applicable current limits must still be respected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why can approximately 19 VDC be measured at an inactive output?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Internal polarization resistors support broken-wire detection. Schneider Electric confirms that a high-impedance voltage measurement on an unloaded, de-energized output does not necessarily indicate an active output. The OFF-state leakage current remains below 0.5 mA.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSources and Editorial Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSchneider Electric official product page: BMXSDO0802 Product Information.\u003c\/li\u003e\n\u003cli\u003eSchneider Electric Modicon M580 Safety System Planning Guide: Safety Module Technical Characteristics.\u003c\/li\u003e\n\u003cli\u003eSchneider Electric technical FAQ: Inactive Output Voltage Explanation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eItems requiring verification before publication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum module current:\u003c\/strong\u003e The product specification lists 10 A, while the M580 Safety Planning Guide specifies a 5 A limit. The 10 A figure is retained from the product listing but should not be used as an installation design limit without confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMTBF:\u003c\/strong\u003e The product description gives 382,097 hours, while the complementary specification lists 383,000 hours. The latter is used in the table.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching frequency:\u003c\/strong\u003e The manufacturer's notation is retained without changing its electrical meaning.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68155898626333,"sku":"BMXSDO0802","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXSDO0802.jpg?v=1795427238","url":"https:\/\/www.6gcontrols.com\/pl\/products\/schneider-electric-bmxsdo0802-modicon-x80-safety-digital-output-module","provider":"6G Controls","version":"1.0","type":"link"}