{"product_id":"abb-560psu01-1kgt006600r0002-power-supply-module","title":"ABB 560PSU01 1KGT006600R0002 Power Supply Module","description":"\u003cp\u003eConfigured for regulated DC power conversion in ABB RTU560 systems, the \u003cstrong\u003eABB 560PSU01\u003c\/strong\u003e (\u003cstrong\u003e560PSU01 Power Supply Module\u003c\/strong\u003e) provides isolated +5 V DC and +24 V DC outputs for RTU560 subracks including 560MPR03 and 560SFR02. The unit supports parallel redundant operation with controlled load sharing and can supply up to four communication modules.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e560PSU01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1KGT006600R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eRTU560 power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Subracks\u003c\/td\u003e\n\u003ctd\u003e560MPR03, 560SFR02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e110-220 VDC (-20% to +15%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e+5 VDC, +24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003eApproximately 44 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Modules\u003c\/td\u003e\n\u003ctd\u003eUp to 4 communication modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eParallel operation with controlled load sharing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\/Output Isolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Interruption Tolerance\u003c\/td\u003e\n\u003ctd\u003eUp to 50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eShort-circuit, input over-voltage, reverse polarity, electronic power limitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNatural convection, fanless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eLED voltage and fault status indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 cm x 20.3 cm x 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRTU560 Power and Redundancy Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 560PSU01 accepts 110-220 VDC input and generates +5 VDC and +24 VDC supply rails for RTU560 subrack hardware. Galvanic isolation separates the input and output circuits. Electronic power limitation and short-circuit protection limit abnormal output conditions.\u003c\/p\u003e\n\u003cp\u003eTwo 560PSU01 units can operate in parallel with controlled load sharing for redundant power configurations. The supplied data specifies tolerance of input interruptions up to 50 ms. LED indicators provide local voltage and fault status indication.\u003c\/p\u003e\n\u003cp\u003eThe fanless natural-convection design eliminates forced-air cooling requirements. Installation must therefore maintain sufficient airflow around the module and avoid obstruction of the natural convection path.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can two 560PSU01 units operate in parallel?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The modules support parallel operation with controlled load sharing for redundant power supply configurations.\u003c\/p\u003e\n\u003cp\u003eQ: What DC output voltages are provided?\u003c\/p\u003e\n\u003cp\u003eA: The module provides +5 VDC and +24 VDC outputs for RTU560 subrack equipment.\u003c\/p\u003e\n\u003cp\u003eQ: What protection functions are specified?\u003c\/p\u003e\n\u003cp\u003eA: The supplied data specifies galvanic isolation, short-circuit protection, electronic power limitation, input over-voltage protection, reverse polarity protection, and tolerance of input interruptions up to 50 ms.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in the specified RTU560 subrack position and verify mechanical engagement before energizing the system.\u003c\/li\u003e\n\u003cli\u003eConfirm that the applied DC input voltage is within the specified 110-220 VDC range, including the stated input tolerance.\u003c\/li\u003e\n\u003cli\u003eVerify the polarity of the DC input wiring before applying power.\u003c\/li\u003e\n\u003cli\u003eKeep power wiring separated from low-level communication and signal wiring where practical to reduce conducted and radiated interference.\u003c\/li\u003e\n\u003cli\u003eBond cable shields according to the RTU560 system grounding design and applicable site electrical standards.\u003c\/li\u003e\n\u003cli\u003eMaintain unobstructed space around the module for natural-convection cooling.\u003c\/li\u003e\n\u003cli\u003eFor redundant configurations, verify correct parallel wiring and controlled load-sharing configuration before placing both power supply units under load.\u003c\/li\u003e\n\u003cli\u003eAfter energization, check the module LEDs for voltage and fault status and verify the +5 VDC and +24 VDC supply rails at the intended subrack interface.\u003c\/li\u003e\n\u003cli\u003eDo not perform wiring changes on energized circuits unless the applicable RTU560 installation procedure explicitly permits the operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52761932366109,"sku":"560PSU01","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/560PSU01-2_1000.jpg?v=1787215420","url":"https:\/\/www.6gcontrols.com\/products\/abb-560psu01-1kgt006600r0002-power-supply-module","provider":"6G Controls","version":"1.0","type":"link"}