{"product_id":"abb-ai830-s800-rtd-analog-input-module","title":"ABB AI830 S800 RTD Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB AI830\u003c\/strong\u003e is an 8-channel RTD analog input module in the ABB S800 I\/O family. It acquires resistance signals from temperature sensors, including Pt100, Ni100, Ni120 and Cu10 elements, and makes the measured values available to the control system for temperature monitoring and process control. Its 14-bit A\/D resolution supports temperature measurement through resistive sensor inputs.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAI830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRTD Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eRTD \/ Resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Sensors\u003c\/td\u003e\n\u003ctd\u003ePt100, Ni100, Ni120, Cu10, Resistive Sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Resolution\u003c\/td\u003e\n\u003ctd\u003e14 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Isolation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eRTD Measurement and Signal Processing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AI830 measures temperature through the resistance characteristics of RTD sensors. Changes in sensor resistance are acquired by the input channels and converted into digital measurement values for the controller. The module supports Pt100, Ni100, Ni120 and Cu10 sensors, as well as resistive elements.\u003c\/p\u003e\n\u003cp\u003eThe 14-bit A\/D conversion provides digital resolution for temperature acquisition. The module performs RTD measurement rather than accepting standard voltage or current process signals such as 4-20 mA.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eChannel Configuration and Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEach channel can be configured individually for the connected sensor type. The AI830\/AI830A RTD module documentation specifies 3-wire RTD connections, with sensors required to be electrically isolated from ground.\u003c\/p\u003e\n\u003cp\u003eThe measurement system includes monitoring for open-circuit and short-circuit conditions. These diagnostics help identify sensor wiring faults that could otherwise appear as abnormal temperature readings.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatible Module Termination Units\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ABB S800 I\/O product documentation identifies the following Module Termination Units (MTUs) for the AI830 configuration:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTU810\u003c\/li\u003e\n\u003cli\u003eTU812\u003c\/li\u003e\n\u003cli\u003eTU814\u003c\/li\u003e\n\u003cli\u003eTU830\u003c\/li\u003e\n\u003cli\u003eTU833\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe MTU provides the field wiring interface between the RTD sensors and the I\/O module. The exact termination unit should be checked against the installed module revision and system configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many RTD sensors can the ABB AI830 monitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The AI830 supports up to 8 RTD input channels. Each channel can be configured individually for supported sensor types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the AI830 accept 4-20 mA or 0-10 V signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The AI830 is an RTD resistance input module. It is designed for resistive temperature sensors rather than conventional analog voltage or current transmitters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the AI830 support thermocouple inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The AI830 is designed for RTD and resistance measurement. Thermocouple applications require a compatible thermocouple input module, such as the ABB AI835A.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52750502887709,"sku":"AI830","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/AI830_1000.jpg?v=1787112213","url":"https:\/\/www.6gcontrols.com\/products\/abb-ai830-s800-rtd-analog-input-module","provider":"6G Controls","version":"1.0","type":"link"}