{"product_id":"abb-do880-3bse028602r1-s800-digital-output-module","title":"ABB DO880 3BSE028602R1 S800 Digital Output Module","description":"\u003cp\u003eThe ABB DO880 3BSE028602R1, also cataloged as the DO880 S800 Digital Output Module, provides 16 current-sourcing output channels for 24 VDC field loads. Each channel supports a rated output current of 0.5 A with current limiting and short-circuit protection. The module supports redundant and high-integrity configurations and provides per-channel status indication and process-power supervision.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO880\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE028602R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e45 x 119 x 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C; +5 to +55 deg C for approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.6 W power dissipation at 0.5 A per channel across 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (19.2-32 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent sourcing, current-limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Integrity\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGroup-wise isolated from ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Cable Length\u003c\/td\u003e\n\u003ctd\u003e600 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+5 V Modulebus Consumption\u003c\/td\u003e\n\u003ctd\u003e45 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+24 V Modulebus Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+24 V External Consumption\u003c\/td\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Supervision\u003c\/td\u003e\n\u003ctd\u003eConfigurable for 50 ohm to 2 kohm loop resistance, depending on configuration and operating mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible MTUs\u003c\/td\u003e\n\u003ctd\u003eTU810, TU812, TU814, TU830, TU833, TU842, TU843, TU852\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying Code\u003c\/td\u003e\n\u003ctd\u003eFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04 G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Approvals\u003c\/td\u003e\n\u003ctd\u003eC1 Div 2 cULus, C1 Zone 2 cULus, ATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certifications\u003c\/td\u003e\n\u003ctd\u003eABS, BV, DNV, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety Standards\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Standards\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4, EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCurrent Limiting and Channel Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe DO880 uses current-sourcing outputs with per-channel current limiting and short-circuit protection. Its output circuits provide group-wise isolation from ground. The module monitors process power for each channel and supports configurable loop supervision based on loop resistance and operating mode.\u003c\/p\u003e\n\u003cp\u003eFront-panel indicators include F (Fault), R (Run), W (Warning), and individual status\/error indicators for channels 1 through 16. Internal diagnostic indications cover module errors, module warnings, and internal channel errors.\u003c\/p\u003e\n\u003cp\u003eThe module supports redundant and high-integrity configurations. The supplied specifications do not identify a specific redundancy switching time or a safety integrity level, so these values must be verified against the applicable ABB system documentation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum output current per channel?\u003c\/p\u003e\n\u003cp\u003eA: Each output channel is rated for 0.5 A at a nominal 24 VDC supply, within the specified 19.2-32 VDC range. The outputs include current limiting and short-circuit protection.\u003c\/p\u003e\n\u003cp\u003eQ: Which mounting termination units are compatible with the DO880?\u003c\/p\u003e\n\u003cp\u003eA: The listed compatible MTUs are TU810, TU812, TU814, TU830, TU833, TU842, TU843, and TU852. Confirm the system configuration and keying code FE before installation.\u003c\/p\u003e\n\u003cp\u003eQ: Does the DO880 support intrinsic safety or HART communication?\u003c\/p\u003e\n\u003cp\u003eA: No. The supplied specifications list intrinsic safety and HART as unsupported. The module is a digital output device rather than a HART-enabled analog interface or intrinsic-safety barrier.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the installed S800 I\/O configuration supports the DO880 and the selected MTU.\u003c\/li\u003e\n\u003cli\u003eConfirm the FE keying code and terminal assignments before connecting field wiring.\u003c\/li\u003e\n\u003cli\u003eCheck the external 24 VDC supply against the specified 19.2-32 VDC operating range.\u003c\/li\u003e\n\u003cli\u003eVerify the load current of each output channel does not exceed 0.5 A.\u003c\/li\u003e\n\u003cli\u003eRoute field signal wiring separately from high-voltage power conductors where practical to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shields according to the site grounding plan and ABB installation documentation.\u003c\/li\u003e\n\u003cli\u003eConfirm field cable length does not exceed 600 m and check loop resistance when loop supervision is enabled.\u003c\/li\u003e\n\u003cli\u003eVerify the enclosure and mounting arrangement meet the IP20 protection requirements and applicable environmental approvals.\u003c\/li\u003e\n\u003cli\u003eFor vertical mounting in a compact MTU, observe the specified maximum ambient temperature of 40 deg C.\u003c\/li\u003e\n\u003cli\u003eCheck the front-panel fault, warning, run, and channel indicators during commissioning. Resolve diagnostic faults before placing the associated outputs into service.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52757652734237,"sku":"DO880 3BSE028602R1","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/DO880-3BSE028602R1-2_1000.jpg?v=1787214835","url":"https:\/\/www.6gcontrols.com\/products\/abb-do880-3bse028602r1-s800-digital-output-module","provider":"6G Controls","version":"1.0","type":"link"}