{"product_id":"abb-dos810-3bse078768r1-select-i-o-digital-output-module","title":"ABB DOS810 3BSE078768R1 Select I\/O Digital Output Module","description":"\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cp\u003eConfigured for 24 VDC digital output control of 2-wire field devices in the ABB Ability System 800xA Select I\/O architecture, the \u003cstrong\u003eABB DOS810\u003c\/strong\u003e (\u003cstrong\u003eDOS810\u003c\/strong\u003e Digital Output Signal Conditioning Module) provides one galvanically isolated output channel with current sourcing up to 0.6 A. The module is powered through Modulebus and supports hot swap, loop supervision, output set to predetermined value (OSP), and field disconnect functions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDOS810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE078768R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Signal Conditioning Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eSelect I\/O \/ ABB Ability System 800xA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Field Devices\u003c\/td\u003e\n\u003ctd\u003e2-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e24 VDC \/ 0.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19.2 to 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power\u003c\/td\u003e\n\u003ctd\u003eCurrent limited; supplied through power injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eElectronic current limitation to 0.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation to system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Robustness\u003c\/td\u003e\n\u003ctd\u003e+\/-35 V between all terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inductor Time Constant\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Load Range\u003c\/td\u003e\n\u003ctd\u003e40 to 5000 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e0.36 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC through Modulebus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eLoop, hardware, communication, internal power, and power injection supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS Barrier\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Integrity\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Installation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e-1000 to 5000 m, restrictions apply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e2 according to IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e77.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e9.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e73 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-4, IEC\/EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Conditions\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61010-1, UL 61010-1, CSA-C22.2 No. 61010-1-12, IEC\/EN 61010-2-201, UL 61010-2-201, CSA C22.2 No. 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certification\u003c\/td\u003e\n\u003ctd\u003eDNV, ABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Certification\u003c\/td\u003e\n\u003ctd\u003eATEX, IECEx, cULus, CCC variants as specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosive Atmosphere\u003c\/td\u003e\n\u003ctd\u003eG3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003ctd\u003eEU RoHS, UAE RoHS, CN RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE\u003c\/td\u003e\n\u003ctd\u003eEU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Select I\/O Digital Output Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe DOS810 uses single-loop granularity, with one Signal Conditioning Module assigned to one I\/O channel. The output sources 24 VDC field power and limits the current electronically to 0.6 A. A built-in free-wheeling diode provides inductive load suppression.\u003c\/p\u003e\n\u003cp\u003eGalvanic isolation separates the field loop from the system side. The module also provides protection against incorrect wiring and monitors open-circuit and short-circuit conditions. Internal hardware, communication, power, and power-injection supervision provide diagnostic status to the Select I\/O system.\u003c\/p\u003e\n\u003cp\u003eThe mechanical locking slider disables field-device power and\/or the output before module removal. A field disconnect function can galvanically separate the field loop from the SCM during commissioning and maintenance. Mechanical keying prevents installation of an incompatible module type.\u003c\/p\u003e\n\u003cp\u003eThe DOS810 supports hazardous-area installation but is not an intrinsic-safety barrier. The supplied certification data includes ATEX, IECEx, cULus hazardous-location, and CCC classifications.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the DOS810 support hot swap?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The DOS810 supports hot swap. The mechanical locking slider can turn off field-device power and\/or the output before removal.\u003c\/p\u003e\n\u003cp\u003eQ: What output current can the DOS810 source?\u003c\/p\u003e\n\u003cp\u003eA: The digital output provides 24 VDC current sourcing with electronic current limitation to 0.6 A.\u003c\/p\u003e\n\u003cp\u003eQ: Does the DOS810 provide galvanic isolation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The field circuit is galvanically isolated from the system. Factory routine testing is specified at 3060 VDC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the DOS810 in the designated Select I\/O mechanical assembly and use the corresponding mechanical keying arrangement to prevent incorrect module insertion.\u003c\/p\u003e\n\u003cp\u003eVerify the field-device wiring against the configured digital-output channel before energization. The module accepts 2-wire field devices and provides current-limited field power through the power injection arrangement.\u003c\/p\u003e\n\u003cp\u003eDuring commissioning or maintenance, use the field disconnect function or mechanical locking slider to isolate the field loop before removing the SCM. Keep field wiring separated from high-energy switching conductors where practical, and terminate cable shields according to the system grounding design.\u003c\/p\u003e\n\u003cp\u003eFor hazardous-area installations, select the applicable certified installation method and observe the restrictions associated with the installed ATEX, IECEx, cULus, or CCC certification. The DOS810 itself is not an IS barrier.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52752605380893,"sku":"DOS810 3BSE078768R1","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/DOS810-3BSE078768R1_1000.jpg?v=1787127245","url":"https:\/\/www.6gcontrols.com\/products\/abb-dos810-3bse078768r1-select-i-o-digital-output-module","provider":"6G Controls","version":"1.0","type":"link"}