{"product_id":"abb-gdc806a1001-gate-drive-and-communication-processor-module","title":"ABB GDC806A1001 Gate Drive and Communication Processor Module","description":"\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB GDC806A1001 (3BHE028761R1001)\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eGDC806A1001\u003c\/strong\u003e Gate Drive and Communication Processor Module, executes gate signal processing and communication functions for power semiconductor control. It uses an Intel Atom E3845 quad-core processor and interfaces with 24 VDC supply, 5 VDC input signals, and CAN, Modbus, with ProfiNet listed as optional.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGDC806A1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e3BHE028761R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eGate Drive and Communication Processor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eIntel Atom E3845 Quad-Core, 1.92 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e2500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eCAN, Modbus, ProfiNet optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGate Drive Response Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 microseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 mm x 100 mm x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGate Drive and Communication Processing\u003c\/h3\u003e\n\u003cp\u003eThe GDC806A1001 combines processor-based communication handling with gate-drive signal processing for power semiconductor control. The Intel Atom E3845 quad-core processor operates at 1.92 GHz and provides the computational platform for communication and real-time control tasks.\u003c\/p\u003e\n\u003cp\u003eThe module accepts 5 VDC input signals and provides a maximum stated output current of 5 A. The specified gate-drive response time is less than 5 microseconds. CAN and Modbus communication are listed as standard interfaces, while ProfiNet is identified as an optional interface.\u003c\/p\u003e\n\u003cp\u003eThe module specifies 2500 VDC isolation voltage between electrically isolated sections. This isolation must be maintained during wiring and system integration according to the applicable ABB hardware documentation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What supply voltage does the GDC806A1001 require?\u003cbr\u003eA: The supplied specification identifies a 24 VDC supply voltage.\u003c\/p\u003e\n\u003cp\u003eQ: What processor is installed on the GDC806A1001?\u003cbr\u003eA: The module uses an Intel Atom E3845 quad-core processor operating at 1.92 GHz.\u003c\/p\u003e\n\u003cp\u003eQ: Which communication interfaces are specified?\u003cbr\u003eA: CAN and Modbus are specified, with ProfiNet listed as an optional communication interface.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the module part number, GDC806A1001 designation, and 3BHE028761R1001 identification before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm the 24 VDC supply polarity and electrical characteristics before energizing the module.\u003c\/li\u003e\n\u003cli\u003eKeep 5 VDC signal wiring separated from high-current switching and power semiconductor conductors where practical.\u003c\/li\u003e\n\u003cli\u003eRoute communication wiring according to the applicable CAN, Modbus, or ProfiNet physical-layer requirements.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified isolation boundaries and do not bypass galvanic isolation through unintended cable shields, bonding paths, or auxiliary wiring.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields and protective earth according to the system grounding design and ABB installation documentation.\u003c\/li\u003e\n\u003cli\u003eProvide mechanical support appropriate for the approximately 120 mm x 100 mm x 25 mm module dimensions.\u003c\/li\u003e\n\u003cli\u003eVerify connector engagement and wiring continuity before applying power or connecting the module to gate-drive circuitry.\u003c\/li\u003e\n\u003cli\u003eDo not substitute communication interfaces or firmware configurations without confirming compatibility with the installed control system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52753914167581,"sku":"3BHE028761R1001 GDC806A1001","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/GDC806A10013BHE028761R10012.jpg?v=1791457053","url":"https:\/\/www.6gcontrols.com\/products\/abb-gdc806a1001-gate-drive-and-communication-processor-module","provider":"6G Controls","version":"1.0","type":"link"}