{"product_id":"abb-gis810-3bse078740r1-generic-i-o-module","title":"ABB GIS810 3BSE078740R1 Generic I\/O Module","description":"\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB GIS810 3BSE078740R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eGIS810\u003c\/strong\u003e Generic I\/O Module, handles I\/O data communication between the Fieldbus Communication Interface (FCI) and Signal Conditioning Modules (SCMs) in the ABB Ability System 800xA Select I\/O architecture. It communicates upstream through Modulebus and supports up to 16 SCMs downstream. The module supports single or redundant configuration and hot swap.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGIS810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE078740R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eGeneric I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eSelect I\/O \/ ABB Ability System 800xA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eModulebus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDownstream SCM Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 16 SCMs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Integrity\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e0.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e-1000 to 5000 m, restrictions apply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e2 according to IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosive Atmosphere\u003c\/td\u003e\n\u003ctd\u003eG3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e77.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e108 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e15.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e76 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.4 W power dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Conditions\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-4, IEC\/EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eCategory II according to IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61010-1, UL 61010-1, CSA-C22.2 No. 61010-1-12, IEC\/EN 61010-2-201, UL 61010-2-201, CSA C22.2 No. 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certification\u003c\/td\u003e\n\u003ctd\u003eDNV, ABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Marking\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUKCA\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area ATEX\u003c\/td\u003e\n\u003ctd\u003eII 3G Ex nA IIC T4 Gc; II 3G Ex ec IIC T4 Gc; II 3G Ex ic nA IIC T4 Gc; II 3G Ex ic ec IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area IECEx\u003c\/td\u003e\n\u003ctd\u003eAvailable on IPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location US\/CAN\u003c\/td\u003e\n\u003ctd\u003ecULus; CL I, ZN 2 and CL I, DIV 2 classifications as specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area CCC\u003c\/td\u003e\n\u003ctd\u003eEx ec IIC T4 Gc; Ex ec ic IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003ctd\u003eEU RoHS, UAE RoHS, CN RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE\u003c\/td\u003e\n\u003ctd\u003eEU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSelect I\/O ModuleBus Communication and Diagnostics\u003c\/h3\u003e\n\u003cp\u003eGIS810 performs the communication layer between the FCI and the SCMs. The upstream interface uses Modulebus, while the downstream side communicates with up to 16 SCMs. Process I\/O data is distributed between the connected SCMs and the FCI.\u003c\/p\u003e\n\u003cp\u003eA mechanical locking slider disconnects the power supplies before module removal. Mechanical keying prevents insertion of an incorrect module type. LED indicators provide Status (S) and Primary (P) indications.\u003c\/p\u003e\n\u003cp\u003eDiagnostics include internal hardware supervision, communication supervision, and internal power supervision. The module can operate in either single or redundant configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the GIS810 support hot swap?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports hot swap. The mechanical locking slider is designed to turn off the power supplies before removal.\u003c\/p\u003e\n\u003cp\u003eQ: How many Signal Conditioning Modules can one GIS810 communicate with?\u003c\/p\u003e\n\u003cp\u003eA: The GIS810 communicates downstream with up to 16 Signal Conditioning Modules.\u003c\/p\u003e\n\u003cp\u003eQ: Can the GIS810 be used in hazardous areas?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The supplied specifications include ATEX, IECEx availability, cULus, and CCC hazardous-area classifications. The applicable certification and installation conditions must be verified for the specific installation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the GIS810 in the designated Select I\/O mechanical position and ensure that the module is correctly keyed before insertion. Verify that the mechanical locking mechanism is engaged according to the installation procedure.\u003c\/p\u003e\n\u003cp\u003eRoute communication and field wiring separately from high-voltage or high-current conductors where practical. Maintain appropriate shielding and grounding practices for the connected I\/O system and avoid creating unintended ground loops.\u003c\/p\u003e\n\u003cp\u003eFor hazardous-area installations, use only the approved installation arrangement and associated equipment required by the applicable ATEX, IECEx, cULus, or other certification. Verify enclosure, wiring, segregation, and environmental requirements before energization.\u003c\/p\u003e\n\u003cp\u003eThe module has an IP20 protection rating; therefore, the surrounding cabinet or enclosure must provide the environmental protection required by the installation. Confirm operating temperature, humidity, altitude, pollution degree, and corrosive-atmosphere conditions against the stated limits.\u003c\/p\u003e\n\u003cp\u003eFor replacement or hot-swap operations, follow the system maintenance procedure and use the mechanical locking slider to remove power from the module before extraction.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52752604463389,"sku":"GIS810 3BSE078740R1","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/GIS810-3BSE078740R1_1000.jpg?v=1787127237","url":"https:\/\/www.6gcontrols.com\/products\/abb-gis810-3bse078740r1-generic-i-o-module","provider":"6G Controls","version":"1.0","type":"link"}