{"product_id":"ge-fanuc-crs22-p8-kti300428-6276-1026-7158-plc-module","title":"GE Fanuc CRS22.P8 \/ KTI300428\/ 6276\/1026\/7158 PLC Module","description":"\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003ch3\u003e\nOverview\n\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp data-start=\"14\" data-end=\"385\"\u003e\nThe \u003cstrong data-start=\"18\" data-end=\"67\"\u003eGE Fanuc CRS22.P8 \/ KTI300428\/ 6276\/1026\/7158\u003c\/strong\u003e is a high-performance PLC module designed for industrial automation. It supports a wide range of control systems used in manufacturing and processing, offering robust performance and seamless integration. Its compact design ensures it fits into standard PLC racks, making it easy to incorporate into existing systems.\n\u003c\/p\u003e\n\u003ch3 data-start=\"387\" data-end=\"415\"\u003e\nTechnical Specifications\n\u003c\/h3\u003e\n\u003ch4 data-start=\"417\" data-end=\"439\"\u003e\n\u003cstrong data-start=\"422\" data-end=\"439\"\u003eFunctionality\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"440\" data-end=\"599\"\u003e\n\u003cli data-start=\"440\" data-end=\"494\"\u003e\n\u003cstrong data-start=\"442\" data-end=\"450\"\u003eType\u003c\/strong\u003e: Programmable Logic Controller (PLC) Module\n\u003c\/li\u003e\n\u003cli data-start=\"495\" data-end=\"599\"\u003e\n\u003cstrong data-start=\"497\" data-end=\"513\"\u003eApplications\u003c\/strong\u003e: Industrial automation tasks, including high\/low limit checking and real-time control\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"601\" data-end=\"622\"\u003e\n\u003cstrong data-start=\"606\" data-end=\"622\"\u003ePower Supply\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"623\" data-end=\"674\"\u003e\n\u003cli data-start=\"623\" data-end=\"674\"\u003e\n\u003cstrong data-start=\"625\" data-end=\"636\"\u003eVoltage\u003c\/strong\u003e: 24V DC (standard industrial voltage)\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"676\" data-end=\"711\"\u003e\n\u003cstrong data-start=\"681\" data-end=\"711\"\u003eInput\/Output Configuration\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"712\" data-end=\"955\"\u003e\n\u003cli data-start=\"712\" data-end=\"734\"\u003e\n\u003cstrong data-start=\"714\" data-end=\"731\"\u003eAnalog Inputs\u003c\/strong\u003e: 8\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"769\"\u003e\n\u003cstrong data-start=\"737\" data-end=\"766\"\u003eIncremental Encoder Input\u003c\/strong\u003e: 1\n\u003c\/li\u003e\n\u003cli data-start=\"770\" data-end=\"801\"\u003e\n\u003cstrong data-start=\"772\" data-end=\"798\"\u003eAbsolute Encoder Input\u003c\/strong\u003e: 1\n\u003c\/li\u003e\n\u003cli data-start=\"802\" data-end=\"824\"\u003e\n\u003cstrong data-start=\"804\" data-end=\"821\"\u003eAnalog Output\u003c\/strong\u003e: 1\n\u003c\/li\u003e\n\u003cli data-start=\"825\" data-end=\"850\"\u003e\n\u003cstrong data-start=\"827\" data-end=\"846\"\u003eDiscrete Inputs\u003c\/strong\u003e: 20\n\u003c\/li\u003e\n\u003cli data-start=\"851\" data-end=\"875\"\u003e\n\u003cstrong data-start=\"853\" data-end=\"872\"\u003eDiscrete Output\u003c\/strong\u003e: 1\n\u003c\/li\u003e\n\u003cli data-start=\"876\" data-end=\"898\"\u003e\n\u003cstrong data-start=\"878\" data-end=\"895\"\u003eRelay Outputs\u003c\/strong\u003e: 8\n\u003c\/li\u003e\n\u003cli data-start=\"899\" data-end=\"928\"\u003e\n\u003cstrong data-start=\"901\" data-end=\"925\"\u003eBrake Control Output\u003c\/strong\u003e: 1\n\u003c\/li\u003e\n\u003cli data-start=\"929\" data-end=\"955\"\u003e\n\u003cstrong data-start=\"931\" data-end=\"952\"\u003eRS-485 Interfaces\u003c\/strong\u003e: 2\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"957\" data-end=\"979\"\u003e\n\u003cstrong data-start=\"962\" data-end=\"979\"\u003eCommunication\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"980\" data-end=\"1081\"\u003e\n\u003cli data-start=\"980\" data-end=\"1081\"\u003e\nSupports \u003cstrong data-start=\"991\" data-end=\"1007\"\u003eGE Fanuc PLC\u003c\/strong\u003e communication protocols for easy integration with other PLCs and devices.\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1083\" data-end=\"1112\"\u003e\n\u003cstrong data-start=\"1088\" data-end=\"1112\"\u003eOperating Conditions\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"1113\" data-end=\"1213\"\u003e\n\u003cli data-start=\"1113\" data-end=\"1213\"\u003e\n\u003cstrong data-start=\"1115\" data-end=\"1136\"\u003eTemperature Range\u003c\/strong\u003e: 0°C to 60°C, ensuring reliable performance in most industrial environments.\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1215\" data-end=\"1243\"\u003e\n\u003cstrong data-start=\"1220\" data-end=\"1243\"\u003ePhysical Dimensions\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"1244\" data-end=\"1327\"\u003e\n\u003cli data-start=\"1244\" data-end=\"1327\"\u003e\n\u003cstrong data-start=\"1246\" data-end=\"1254\"\u003eSize\u003c\/strong\u003e: Compact, designed to fit into standard PLC racks for easy installation.\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1329\" data-end=\"1349\"\u003e\n\u003cstrong data-start=\"1334\" data-end=\"1349\"\u003ePerformance\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"1350\" data-end=\"1427\"\u003e\n\u003cli data-start=\"1350\" data-end=\"1427\"\u003e\nDelivers reliable, real-time control with high precision and dependability.\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1429\" data-end=\"1451\"\u003e\n\u003cstrong data-start=\"1434\" data-end=\"1451\"\u003eCompatibility\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"1452\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1452\" data-end=\"1516\"\u003e\nCompatible with \u003cstrong data-start=\"1470\" data-end=\"1495\"\u003eGE Fanuc Series 90-30\u003c\/strong\u003e and similar systems.\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1518\" data-end=\"1538\"\u003e\n\u003cstrong data-start=\"1523\" data-end=\"1538\"\u003eReliability\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"1539\" data-end=\"1632\"\u003e\n\u003cli data-start=\"1539\" data-end=\"1632\"\u003e\nBuilt for industrial environments with a robust, durable construction to minimize downtime.\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1634\" data-end=\"1653\"\u003e\n\u003cstrong data-start=\"1639\" data-end=\"1653\"\u003eConnectors\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"1654\" data-end=\"1812\"\u003e\n\u003cli data-start=\"1654\" data-end=\"1684\"\u003e\nMultiple integrated circuits\n\u003c\/li\u003e\n\u003cli data-start=\"1685\" data-end=\"1709\"\u003e\nTwo female phone plugs\n\u003c\/li\u003e\n\u003cli data-start=\"1710\" data-end=\"1740\"\u003e\nA three-pin female connector\n\u003c\/li\u003e\n\u003cli data-start=\"1741\" data-end=\"1812\"\u003e\nTwo light-emitting diodes (LEDs) for diagnostic and status monitoring\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1814\" data-end=\"1842\"\u003e\n\u003cstrong data-start=\"1819\" data-end=\"1842\"\u003eAdditional Features\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"1843\" data-end=\"1920\"\u003e\n\u003cli data-start=\"1843\" data-end=\"1865\"\u003e\n\u003cstrong data-start=\"1845\" data-end=\"1855\"\u003eRelays\u003c\/strong\u003e: 12 total\n\u003c\/li\u003e\n\u003cli data-start=\"1866\" data-end=\"1920\"\u003e\n\u003cstrong data-start=\"1868\" data-end=\"1888\"\u003eSurge Protection\u003c\/strong\u003e: 6 metal oxide varistors (MOVs)\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1922\" data-end=\"1945\"\u003e\n\u003cstrong data-start=\"1927\" data-end=\"1945\"\u003eCertifications\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"1946\" data-end=\"2005\"\u003e\n\u003cli data-start=\"1946\" data-end=\"1955\"\u003e\n\u003cstrong data-start=\"1948\" data-end=\"1955\"\u003eSWC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1956\" data-end=\"1973\"\u003e\n\u003cstrong data-start=\"1958\" data-end=\"1973\"\u003eC37.990 EMI\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1974\" data-end=\"2005\"\u003e\n\u003cstrong data-start=\"1976\" data-end=\"2005\"\u003eRFI Interference Immunity\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52755033850141,"sku":null,"price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/GE-Fanuc-CRS22_P8-KTI300428-6276-1026-7158_1000.jpg?v=1787186768","url":"https:\/\/www.6gcontrols.com\/products\/ge-fanuc-crs22-p8-kti300428-6276-1026-7158-plc-module","provider":"6G Controls","version":"1.0","type":"link"}