{"product_id":"ge-fanuc-m60e00vfhf8fh6dm8fp6c-motor-protection-relay","title":"GE Fanuc M60E00VFHF8FH6DM8FP6C Motor Protection Relay","description":"\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003ch3\u003e\nOverview\n\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp data-start=\"65\" data-end=\"396\"\u003e\nThe \u003cstrong data-start=\"69\" data-end=\"103\"\u003eGE Fanuc M60E00VFHF8FH6DM8FP6C\u003c\/strong\u003e is a \u003cstrong data-start=\"109\" data-end=\"135\"\u003emotor protection relay\u003c\/strong\u003e from the \u003cstrong data-start=\"145\" data-end=\"168\"\u003eMultilin M60 series\u003c\/strong\u003e. It provides \u003cstrong data-start=\"182\" data-end=\"222\"\u003ecomprehensive protection and control\u003c\/strong\u003e for medium to large three-phase motors. With \u003cstrong data-start=\"268\" data-end=\"318\"\u003eadvanced automation and communication features\u003c\/strong\u003e, it suits \u003cstrong data-start=\"329\" data-end=\"356\"\u003eindustrial applications\u003c\/strong\u003e requiring reliability and efficiency.\n\u003c\/p\u003e\n\u003ch3 data-start=\"398\" data-end=\"432\"\u003e\n\u003cstrong data-start=\"402\" data-end=\"430\"\u003eTechnical Specifications\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003ch4 data-start=\"434\" data-end=\"458\"\u003e\n\u003cstrong data-start=\"439\" data-end=\"456\"\u003eModel Details\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"459\" data-end=\"547\"\u003e\n\u003cli data-start=\"459\" data-end=\"506\"\u003e\n\u003cp data-start=\"461\" data-end=\"506\"\u003e\n\u003cstrong data-start=\"461\" data-end=\"478\"\u003eModel Number:\u003c\/strong\u003e \u003cstrong data-start=\"479\" data-end=\"504\"\u003eM60E00VFHF8FH6DM8FP6C\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"507\" data-end=\"547\"\u003e\n\u003cp data-start=\"509\" data-end=\"547\"\u003e\n\u003cstrong data-start=\"509\" data-end=\"518\"\u003eType:\u003c\/strong\u003e \u003cstrong data-start=\"519\" data-end=\"545\"\u003eMotor Protection Relay\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"549\" data-end=\"585\"\u003e\n\u003cstrong data-start=\"554\" data-end=\"583\"\u003eElectrical Specifications\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"586\" data-end=\"745\"\u003e\n\u003cli data-start=\"586\" data-end=\"625\"\u003e\n\u003cp data-start=\"588\" data-end=\"625\"\u003e\n\u003cstrong data-start=\"588\" data-end=\"612\"\u003eControl Power Input:\u003c\/strong\u003e \u003cstrong data-start=\"613\" data-end=\"623\"\u003e24 VDC\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"626\" data-end=\"668\"\u003e\n\u003cp data-start=\"628\" data-end=\"668\"\u003e\n\u003cstrong data-start=\"628\" data-end=\"646\"\u003eVoltage Range:\u003c\/strong\u003e \u003cstrong data-start=\"647\" data-end=\"666\"\u003e100V to 690V AC\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"669\" data-end=\"705\"\u003e\n\u003cp data-start=\"671\" data-end=\"705\"\u003e\n\u003cstrong data-start=\"671\" data-end=\"685\"\u003eFrequency:\u003c\/strong\u003e \u003cstrong data-start=\"686\" data-end=\"703\"\u003e50 Hz \/ 60 Hz\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"706\" data-end=\"745\"\u003e\n\u003cp data-start=\"708\" data-end=\"745\"\u003e\n\u003cstrong data-start=\"708\" data-end=\"727\"\u003eCurrent Rating:\u003c\/strong\u003e \u003cstrong data-start=\"728\" data-end=\"743\"\u003e1A to 1000A\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"747\" data-end=\"783\"\u003e\n\u003cstrong data-start=\"752\" data-end=\"781\"\u003eCommunication and Display\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"784\" data-end=\"904\"\u003e\n\u003cli data-start=\"784\" data-end=\"856\"\u003e\n\u003cp data-start=\"786\" data-end=\"856\"\u003e\n\u003cstrong data-start=\"786\" data-end=\"814\"\u003eCommunication Protocols:\u003c\/strong\u003e \u003cstrong data-start=\"815\" data-end=\"854\"\u003eModbus TCP\/IP, Modbus RTU, Ethernet\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"857\" data-end=\"904\"\u003e\n\u003cp data-start=\"859\" data-end=\"904\"\u003e\n\u003cstrong data-start=\"859\" data-end=\"871\"\u003eDisplay:\u003c\/strong\u003e \u003cstrong data-start=\"872\" data-end=\"902\"\u003e3.5\" full-color LCD screen\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"906\" data-end=\"947\"\u003e\n\u003cstrong data-start=\"911\" data-end=\"945\"\u003eInputs and Protection Features\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"948\" data-end=\"1310\"\u003e\n\u003cli data-start=\"948\" data-end=\"1035\"\u003e\n\u003cp data-start=\"950\" data-end=\"1035\"\u003e\n\u003cstrong data-start=\"950\" data-end=\"982\"\u003eConfigurable Digital Inputs:\u003c\/strong\u003e \u003cstrong data-start=\"983\" data-end=\"1033\"\u003eSupports start\/stop signals, alarms, and trips\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1036\" data-end=\"1310\"\u003e\n\u003cp data-start=\"1038\" data-end=\"1064\"\u003e\n\u003cstrong data-start=\"1038\" data-end=\"1062\"\u003eProtection Features:\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul data-start=\"1067\" data-end=\"1310\"\u003e\n\u003cli data-start=\"1067\" data-end=\"1097\"\u003e\n\u003cp data-start=\"1069\" data-end=\"1097\"\u003e\n\u003cstrong data-start=\"1069\" data-end=\"1095\"\u003eOvercurrent protection\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1100\" data-end=\"1130\"\u003e\n\u003cp data-start=\"1102\" data-end=\"1130\"\u003e\n\u003cstrong data-start=\"1102\" data-end=\"1128\"\u003eEarth fault protection\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1133\" data-end=\"1167\"\u003e\n\u003cp data-start=\"1135\" data-end=\"1167\"\u003e\n\u003cstrong data-start=\"1135\" data-end=\"1165\"\u003ePhase imbalance protection\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1170\" data-end=\"1205\"\u003e\n\u003cp data-start=\"1172\" data-end=\"1205\"\u003e\n\u003cstrong data-start=\"1172\" data-end=\"1203\"\u003eThermal overload protection\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1208\" data-end=\"1246\"\u003e\n\u003cp data-start=\"1210\" data-end=\"1246\"\u003e\n\u003cstrong data-start=\"1210\" data-end=\"1244\"\u003eStator ground fault protection\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1249\" data-end=\"1281\"\u003e\n\u003cp data-start=\"1251\" data-end=\"1281\"\u003e\n\u003cstrong data-start=\"1251\" data-end=\"1279\"\u003eLoss of field protection\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1284\" data-end=\"1310\"\u003e\n\u003cp data-start=\"1286\" data-end=\"1310\"\u003e\n\u003cstrong data-start=\"1286\" data-end=\"1308\"\u003eVoltage protection\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1312\" data-end=\"1351\"\u003e\n\u003cstrong data-start=\"1317\" data-end=\"1349\"\u003eEnvironmental Specifications\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"1352\" data-end=\"1419\"\u003e\n\u003cli data-start=\"1352\" data-end=\"1419\"\u003e\n\u003cp data-start=\"1354\" data-end=\"1419\"\u003e\n\u003cstrong data-start=\"1354\" data-end=\"1380\"\u003eOperating Temperature:\u003c\/strong\u003e \u003cstrong data-start=\"1381\" data-end=\"1417\"\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52755248152861,"sku":"M60E00VFHF8FH6DM8FP6C","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/GE-Fanuc-M60E00VFHF8FH6DM8FP6C_1000.jpg?v=1787194081","url":"https:\/\/www.6gcontrols.com\/products\/ge-fanuc-m60e00vfhf8fh6dm8fp6c-motor-protection-relay","provider":"6G Controls","version":"1.0","type":"link"}