{"product_id":"ge-multilin-g30-generator-protection-systems","title":"GE Multilin G30 Generator Protection Systems","description":"\u003cp\u003eThe GE Multilin \u003cstrong\u003eG30\u003c\/strong\u003e Generator Protection System offers advanced protection for small to medium-sized generators, including combined generator and transformer protection. It is built on the industry-leading UR platform and is ideal for steam, hydraulic, and combustion-turbine generators in various applications. The G30 excels in scenarios where both the generator and transformer require protection within the same zone, delivering cost-effective solutions in a single device. Moreover, it ensures advanced communication capabilities through an integrated managed Ethernet switch and supports standard communication protocols like IEC 61850. The G30, a member of the UR family of protection relays, is your reliable choice for safeguarding small to medium-sized generators and applications that demand combined generator and transformer protection.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nSmall to medium-sized generators typically driven by steam, gas or hydraulic turbines\n\u003c\/li\u003e\n\u003cli\u003e\nPumped storage generators\n\u003c\/li\u003e\n\u003cli\u003e\nCombined generator and transformer in the zone of protection•Distributed Generator (DG) interconnect protection as per IEEE 154\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003cspan data-redactor-tag=\"span\"\u003eKEY BENEFIT\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nComplete protection for small to medium-sized generators\n\u003c\/li\u003e\n\u003cli\u003e\nAdvanced automation capabilities for providing customized protection and control solutions\n\u003c\/li\u003e\n\u003cli\u003e\nCombined generator and transformer protection\n\u003c\/li\u003e\n\u003cli\u003e\nThree independent fiber or copper Ethernet ports for simultaneous\/ dedicated network connections with advanced 1 microsecond time synchronization via LAN with IEEE® 1588 support\n\u003c\/li\u003e\n\u003cli\u003e\nHigh-speed peer-to-peer communications reduces relay-to-relay wiring and associated installation costs\n\u003c\/li\u003e\n\u003cli\u003e\nEmbedded IEC®61850 protocol\n\u003c\/li\u003e\n\u003cli\u003e\nIncrease network availability by reducing failover time to zero through IEC 62439-3 \"PRP\" support\n\u003c\/li\u003e\n\u003cli\u003e\nCyberSentry™ provides high-end cyber security aligned to industry standards and services (NERC® CIP, AAA, Radius, RBAC, Syslog)\n\u003c\/li\u003e\n\u003cli\u003e\nRobust network security enabling Critical Infrastructure Protection through user command logging, and dual permission access control\n\u003c\/li\u003e\n\u003cli\u003e\nHigh-end fault and disturbance recording eliminates the need for redundant recording devices\n\u003c\/li\u003e\n\u003cli\u003e\nComplete IEC 61850 Process Bus solution provides resource optimization and minimizes total P\u0026amp;C life cycle costs\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eFEATURES\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProtection and Control\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\nOverall unit differential including transformer\n\u003c\/li\u003e\n\u003cli\u003e\nRestricted ground fault, thermal overload protection, directional, time, instantaneous, phase, neutral, negative sequence and ground overcurrent protection\n\u003c\/li\u003e\n\u003cli\u003e\nSplit-phase protection\n\u003c\/li\u003e\n\u003cli\u003e\nLoss of excitation, overexcitation\n\u003c\/li\u003e\n\u003cli\u003e\nThird harmonic neutral undervoltage\n\u003c\/li\u003e\n\u003cli\u003e\nGenerator unbalance\n\u003c\/li\u003e\n\u003cli\u003e\nReverse and low forward power\n\u003c\/li\u003e\n\u003cli\u003e\nAccidental energization\n\u003c\/li\u003e\n\u003cli\u003e\nSynchronism check\n\u003c\/li\u003e\n\u003cli\u003e\nPhase sequence reversal for pumped storage\n\u003c\/li\u003e\n\u003cli\u003e\nCT failure for each CT bank, VT fuse failure\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommunications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\nNetworking interfaces: up to three Ethernet ports 100Mb fiber or copper, RS485, RS232, RS422, G.703, C37.94\n\u003c\/li\u003e\n\u003cli\u003e\nMultiple protocols: IEC 61850, DNP 3.0 and Modbus® serial\/TCP, IEEE 1588, IEC 60870-5-104 and 103, PRP, SNTP, HTTP, TFTP, EGD\n\u003c\/li\u003e\n\u003cli\u003e\nDirect I\/O: secure, high-speed exchange of data between URs for transformer tripping applications\n\u003c\/li\u003e\n\u003cli\u003e\nEmbedded managed Ethernet switch with four 100 Mbit fiber optic ports and 2 copper portsIEC 61850 Process Bus Interface\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\r\nIEC 61850 Process Bus Interface\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\nRobust communications with up to 8 HardFiber Bricks\n\u003c\/li\u003e\n\u003cli\u003e\nRedundant architecture for dependability and securityMonitoring and Metering\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMonitoring and Metering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\nMetering: current, voltage, power, energy, frequency\n\u003c\/li\u003e\n\u003cli\u003e\nAdvanced recording capabilities deliver a 1024 event recorder, configurable and extended waveform capture and data logger\n\u003c\/li\u003e\n\u003cli\u003e\nSetting for security audit trails for tracking changes to G30 configurationsEnerVistaTM Software•Graphical Logic Designer and Logic Monitor to simplify designing and testing procedures via EnerVista UR Engineer\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnerVistaTM Software\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\nService and update notification toolset ensures device documents and software are up-to-date via EnerVista Launchpad\n\u003c\/li\u003e\n\u003cli\u003e\nEnerVista Integrator providing easy integration of data in the G30 into new or existing monitoring and control systems\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.6gcontrols.com\/wp-content\/uploads\/2023\/10\/20231027112654-1024x506.png\" alt=\"GE Multilin G30 Functional Block Diagram\" style=\"max-width:100%;height:auto;display:block;margin:1em 0;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more in-depth product information, please click to download or access the document online ：\u003c\/strong\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.6gcontrols.com\/wp-content\/uploads\/2023\/10\/GE_G30_-_Brochure100.pdf\"\u003eGE_G30_-_Brochure100\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\nAbout Us 🌍🛒\n\u003c\/h3\u003e\n\u003cp\u003eWith 13 years of global supply experience, we pride ourselves on providing top-quality products through direct foreign purchases. Our offerings include genuine licensed products, unbeatable prices, comprehensive model selections, and ample inventory.\u003c\/p\u003e\n\u003cp\u003e🎉 Special Offer: For orders of more than 1 product, reach out to us, and we'll happily provide a discount to sweeten the deal.\u003c\/p\u003e\n\u003cp\u003eHave questions or inquiries? We're here to assist you! Feel free to get in touch.\u003c\/p\u003e\n\u003cp\u003e💰 Price Match Guarantee: If you find the same parts at a lower price elsewhere, we'll match it or even provide an extra discount.\u003c\/p\u003e\n\u003cp\u003eNeed spare parts? Just let us know, and we'll be delighted to assist. Your inquiry is eagerly awaited.\u003c\/p\u003e\n\u003ch3\u003e\nContact Us 📞\n\u003c\/h3\u003e\n\u003cp\u003e📧 Email: \u003ca href=\"mailto:sales6@5gplc.com\" target=\"_new\" rel=\"noopener\"\u003esales6@5gplc.com\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e🕒 Business Hours: 24\/7\u003c\/p\u003e\n\u003cp\u003e🏢 Address: No.601, Hongwen Liuli, Siming District, Xiamen, China\u003c\/p\u003e\n\u003ctable class=\"product-specs\" style=\"border-collapse: collapse; width: 344px; height: 975px;\" border=\"0\" width=\"775\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et3\" style=\"height: 202.50pt; width: 144.75pt; border-bottom: .5pt solid #000000;\" rowspan=\"10\" width=\"193\" height=\"270\"\u003e\nGE\n\u003c\/td\u003e\n\u003ctd class=\"et4\" style=\"width: 436.50pt;\" width=\"582\"\u003e\nUR8FH\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et4\"\u003e\nUR9NH\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et4\"\u003e\nUR9GH\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et4\"\u003e\nUR6CH\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et4\"\u003e\nUR6DH\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et4\"\u003e\nUR67H\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et4\"\u003e\n239\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et4\"\u003e\nUR8HH\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et4\"\u003e\nUR6EH\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et4\"\u003e\nUR9EH\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et7\" style=\"height: 20.25pt;\" height=\"27\"\u003e\nGE\n\u003c\/td\u003e\n\u003ctd class=\"et4\"\u003e\nIS200WETAH1AEC\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et7\" style=\"height: 81.00pt;\" rowspan=\"4\" height=\"108\"\u003e\nGE\n\u003c\/td\u003e\n\u003ctd class=\"et8\"\u003e\nIS220PAICH1B\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et4\"\u003e\nGE342A4903ADP224L\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et4\"\u003e\nIS200STAIH2ACB\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et4\"\u003e\nIS230SNAIH2A\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et7\" style=\"height: 20.25pt;\" height=\"27\"\u003e\nGE\n\u003c\/td\u003e\n\u003ctd class=\"et4\"\u003e\n239\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et9\" style=\"height: 81.00pt;\" rowspan=\"4\" height=\"108\"\u003e\nGE\n\u003c\/td\u003e\n\u003ctd class=\"et8\"\u003e\nIS200AEPAH1AFD\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et8\"\u003e\nIS210BPPCH1AEC\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et8\"\u003e\nIS200WETAH1AEC IS215WETAH1BB\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et8\"\u003e\n750-P5-G1-S1-HI-A20-R\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et9\" style=\"height: 141.75pt;\" rowspan=\"7\" height=\"189\"\u003e\nGE\n\u003c\/td\u003e\n\u003ctd class=\"et9\"\u003e\nURRHH\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et9\"\u003e\nUR9NH\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et9\"\u003e\nUR8LH\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et9\"\u003e\nUR4DH\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et9\"\u003e\nUR67H\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et9\"\u003e\nUR8NH\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et9\"\u003e\nG30\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.25pt;\"\u003e\n\u003ctd class=\"et9\" style=\"height: 20.25pt;\" height=\"27\"\u003e\nGE\n\u003c\/td\u003e\n\u003ctd class=\"et8\"\u003e\n\u003ca href=\"https:\/\/www.6gcontrols.com\/products\/ge-is200aepbhibaa-151x1225ek01pc04-battery-charger-bench-pcb\/\"\u003eIS200AEPBHIBAA 151X1225EK01PC04\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52751334899997,"sku":"G30","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/raw_1000.jpg?v=1787115239","url":"https:\/\/www.6gcontrols.com\/products\/ge-multilin-g30-generator-protection-systems","provider":"6G Controls","version":"1.0","type":"link"}