{"product_id":"honeywell-10102-2-1-fail-safe-analog-input-module-4-channels","title":"Honeywell 10102\/2\/1 Fail-safe analog input module (4 channels)","description":"\u003ch3\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h3\u003e\r\nThe fail-safe analog input module 10102\/2\/1 is equipped with four 0-2 V analog input channels. These analog inputs share a common 0 V connection but are galvanically isolated from the 24 Vdc and 5 Vdc supplies.\r\n\r\nThe analog inputs can be used actively, with each input having a separate 26 Vdc, \u0026gt; 20 mA short-circuit protected output, or passively, where the supply is directly connected to the transmitter.\r\n\r\nThe input stage of 10102\/2\/1 features a high input impedance, allowing the connection of two 10102\/2\/1 modules in parallel. However, each input requires an analog input converter module 10102\/A\/ (refer to the 10102\/A\/ data sheets).\r\n\r\n\u003cstrong\u003eNote:\u003c\/strong\u003e As the inputs require a 10102\/A\/ converter module, the 10102\/2\/1 module can only be used in combination with an I\/O backplane in the rack.\r\n\r\nThe analog input module performs scans on the analog inputs, the 26 V output voltages, internal supply voltages, and a reference voltage generated by a D\/A converter. This D\/A converter generates various reference voltages used to comprehensively test the analog input module. The self-test includes a leakage test of the input filter, which could affect the accuracy of the analog input value.\r\n\r\n\u003cstrong\u003eWithin the configured process safety time, the analog inputs are tested for:\u003c\/strong\u003e\r\n\u003cul\u003e\r\n \t\u003cli\u003eAbsolute accuracy\u003c\/li\u003e\r\n \t\u003cli\u003eCorrect conversion over the full range\u003c\/li\u003e\r\n \t\u003cli\u003eCrosstalk between inputs\u003c\/li\u003e\r\n \t\u003cli\u003eOutput voltage of the 26 Vdc outputs\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\nThe 26 Vdc outputs are generated by the DC\/DC converter and stabilized at 26 Vdc, making them independent of the incoming 24 Vdc supply.\r\n\r\n\u003cstrong\u003eNote:\u003c\/strong\u003e The maximum output current is at least 21 mA. If the transmitters require a higher supply current, the input channel must be used in passive mode (= external supply).\r\n\r\n\u003cstrong\u003eAnalog Input Ranges for FSC:\u003c\/strong\u003e\r\n\r\nTable 1 provides an overview of the analog input ranges for the FSC system and how the 10102\/2\/1 module can be used for each of these ranges.\r\n\r\nTable 1: Overview of analog inputs for FSC\r\n\u003cul\u003e\r\n \t\u003cli\u003e0(4)-20 mA Internal power: 10102\/2\/1 + 10102\/A\/1\u003c\/li\u003e\r\n \t\u003cli\u003e0(4)-20 mA External power: 10102\/2\/1 + 10102\/A\/2\u003c\/li\u003e\r\n \t\u003cli\u003e0(1)-5 V External power: 10102\/2\/1 + 10102\/A\/3\u003c\/li\u003e\r\n \t\u003cli\u003e0(2)-10 V External power: 10102\/2\/1 + 10102\/A\/4\u003c\/li\u003e\r\n \t\u003cli\u003eLoop-monitored digital input: 10102\/2\/1 + 10102\/A\/5\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\nOther analog input signals such as thermocouples, PT-100, etc., can only be used after conversion to one of the analog input ranges that the FSC system can handle.\r\n\u003ch3\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003c\/h3\u003e\r\nThe 10102\/2\/1 module specifications include:\r\n\u003cul\u003e\r\n \t\u003cli\u003eGeneral Type number: 10102\/2\/1 11301*\u003c\/li\u003e\r\n \t\u003cli\u003eApprovals: CE, TÜV, UL\u003c\/li\u003e\r\n \t\u003cli\u003eSoftware versions: ≥ 3.00\u003c\/li\u003e\r\n \t\u003cli\u003eSpace requirements: 4 TE, 3 HE (= 4 HP, 3U)\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cstrong\u003ePower:\u003c\/strong\u003e\r\n\u003cul\u003e\r\n \t\u003cli\u003ePower requirements: 5 Vdc 30 mA\u003c\/li\u003e\r\n \t\u003cli\u003e24 Vdc 175 mA + 25 mA for each active input\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cstrong\u003eInput:\u003c\/strong\u003e\r\n\u003cul\u003e\r\n \t\u003cli\u003eNumber of input channels: 4\u003c\/li\u003e\r\n \t\u003cli\u003eInput specification (V): 0-2 Vdc\u003c\/li\u003e\r\n \t\u003cli\u003eInput resistance: \u0026gt; 100 kOhm\u003c\/li\u003e\r\n \t\u003cli\u003eLoop powering: 26 Vdc (±1 V for 0.2 mA \u0026lt; I \u0026lt; 20 mA), short-circuit protected\u003c\/li\u003e\r\n \t\u003cli\u003eLoop current limit: \u0026gt; 21 mA solid-state\u003c\/li\u003e\r\n \t\u003cli\u003eA\/D converter: 12-bit\u003c\/li\u003e\r\n \t\u003cli\u003eInaccuracy: ≤ 0.75%\u003c\/li\u003e\r\n \t\u003cli\u003eAbsolute max. input signal: ± 5 Vdc\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cstrong\u003eKey Coding:\u003c\/strong\u003e Refer to the 'Key Coding' data sheet for details on key coding.\r\n\r\n\u003cstrong\u003eModule Connector Code:\u003c\/strong\u003e\r\n\u003cul\u003e\r\n \t\u003cli\u003eHoles A5, C17\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cstrong\u003eRack Connector Code:\u003c\/strong\u003e\r\n\u003cul\u003e\r\n \t\u003cli\u003eLarge pins A5, C17\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cem\u003eNotes:\u003c\/em\u003e 10102\/2\/1 modules with suffix code 11301 have improved EMC behavior.\r\n\u003ch3 id=\"more-products\"\u003eMore Products:\u003c\/h3\u003e\r\n\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003eCC-TDIL01\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003eCC-PSV201\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003eCC-PDOB01\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003e\u003ca href=\"https:\/\/www.6gcontrols.com\/products\/honeywell-cc-tdob01-51308371-175-digital-output-module-high-quality\/\"\u003eCC-TDOB01\u003c\/a\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003e\u003ca href=\"https:\/\/www.6gcontrols.com\/products\/honeywell-10216-2-1-fail-safe-digital-output-module\/\"\u003e10216\/2\/1\u003c\/a\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003e\u003ca href=\"https:\/\/www.6gcontrols.com\/products\/honeywell-cc-pain01-analog-input-module-in-stock\/\"\u003eCC-PAIN01\u003c\/a\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003e\u003ca href=\"https:\/\/www.6gcontrols.com\/products\/honeywell-cc-paim01-51405045-175-analog-input-module\/\"\u003eCC-PAIM01\u003c\/a\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003e\u003ca href=\"https:\/\/www.6gcontrols.com\/products\/honeywell-10106-2-1-digital-input-module-in-stock\/\"\u003e10106\/2\/1\u003c\/a\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003e\u003ca href=\"https:\/\/www.6gcontrols.com\/products\/honeywell-10002-1-2-cpu-module-brand-new-in-stock\/\"\u003e10002\/1\/2\u003c\/a\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003e\u003ca href=\"https:\/\/www.6gcontrols.com\/products\/100-brand-new-honeywell-10303-1-1-power-supply-module\/\"\u003e10303\/1\/1\u003c\/a\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003e\u003ca href=\"https:\/\/www.6gcontrols.com\/products\/honeywell-10006-2-1-diagnostic-and-battery-module-dbm\/\"\u003e10006\/2\/1\u003c\/a\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003e10102\/2\/1\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003e10313\/1\/1\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003e10101\/2\/1\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003eTC-IDD321\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003e10018\/2\/U\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003eTC-OAV081\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003eFC-PDIO01\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003eCC-PCNT01 51405046-175\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003eCC-PDIL01 51405040-176\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003eCC-PFB401 51405044-175\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003e10018\/O\/1\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003eCC-PCF091 51405047-176\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003eCC-PCNT02 51454551-275\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003eCC-PUIO01\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHONEYWELL\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003eFS-SDOL-0424\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"128\"\u003eHoneywell\u003c\/td\u003e\r\n\u003ctd width=\"597\"\u003eCC-GAIX21\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52750312440093,"sku":"10102\/2\/1 1010221","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/1010221_1__1000.jpg?v=1787043654","url":"https:\/\/www.6gcontrols.com\/products\/honeywell-10102-2-1-fail-safe-analog-input-module-4-channels","provider":"6G Controls","version":"1.0","type":"link"}