{"product_id":"honeywell-tc-rpa002-controlnet-modular-repeater-adapter","title":"Honeywell TC-RPA002 ControlNet Modular Repeater Adapter","description":"\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cp\u003eThe Honeywell TC-RPA002 is a ControlNet Modular Repeater Adapter designed to provide fiber-optic connectivity within Honeywell ControlNet communication networks. It supports up to four fiber modules and operates at a communication rate of 5 Mbits\/s. The adapter uses a nominal 24 VDC external supply and provides the interface and backplane connections required by the repeater modules.\u003c\/p\u003e\n\u003ch3\u003eControlNet Fiber-Optic Communication\u003c\/h3\u003e\n\u003cp\u003eThe TC-RPA002 serves as the adapter platform for fiber-optic repeater modules in a ControlNet network. It allows the network to use fiber-optic links between communication segments rather than relying exclusively on coaxial cable.\u003c\/p\u003e\n\u003cp\u003eThe adapter supports up to four fiber modules, with two fiber ports per module. This modular arrangement allows the fiber interface configuration to be selected according to the required network topology and optical connection points.\u003c\/p\u003e\n\u003ch3\u003ePower Supply and Backplane Interface\u003c\/h3\u003e\n\u003cp\u003eThe adapter requires a nominal 24 VDC supply, with an allowable input range of 18 to 36 VDC. Its maximum current consumption is 700 mA under worst-case fiber-module loading.\u003c\/p\u003e\n\u003cp\u003eThe repeater backplane provides a maximum output current of 1.6 A at 5 VDC for the installed fiber modules. The power supply and repeater backplane connections have an isolation rating tested at 850 VDC for 1 second.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-RPA002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eControlNet Modular Repeater Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Type\u003c\/td\u003e\n\u003ctd\u003eControlNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Rate\u003c\/td\u003e\n\u003ctd\u003e5 Mbits\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Module Capacity\u003c\/td\u003e\n\u003ctd\u003e4 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Ports\u003c\/td\u003e\n\u003ctd\u003e2 per fiber module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18 to 36 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e700 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeater Backplane Output Current\u003c\/td\u003e\n\u003ctd\u003e1.6 A maximum at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e850 VDC for 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e5 g at 10 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Shock\u003c\/td\u003e\n\u003ctd\u003e30 g peak, 11 (+\/-1) ms pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Operating Shock\u003c\/td\u003e\n\u003ctd\u003e50 g peak, 11 (+\/-1) ms pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Conductor Wire Size\u003c\/td\u003e\n\u003ctd\u003e14 to 24 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many fiber modules can the TC-RPA002 accommodate?\u003c\/p\u003e\n\u003cp\u003eA: The TC-RPA002 supports up to four fiber modules, with two fiber ports per module. The actual optical configuration depends on the selected fiber modules.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply does the TC-RPA002 require?\u003c\/p\u003e\n\u003cp\u003eA: It requires a nominal 24 VDC supply and accepts 18 to 36 VDC. Maximum current consumption is 700 mA under worst-case module loading.\u003c\/p\u003e\n\u003cp\u003eQ: What is the communication rate of the TC-RPA002?\u003c\/p\u003e\n\u003cp\u003eA: The adapter supports a ControlNet communication rate of 5 Mbits\/s. This is the network communication rate, not an optical transmission distance specification.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52756893663517,"sku":"TC-RPA002","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/TC-RPA002_1000.jpg?v=1787207594","url":"https:\/\/www.6gcontrols.com\/products\/honeywell-tc-rpa002-controlnet-modular-repeater-adapter","provider":"6G Controls","version":"1.0","type":"link"}