{"product_id":"schneider-electric-bmeahi0812-analog-input-module","title":"Schneider Electric BMEAHI0812 Analog Input Module","description":"\u003ch2\u003e\nSchneider Electric BMEAHI0812 Analog Input Module\n\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMEAHI0812\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eBMEAHI0812\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for isolated 4-20 mA HART signal acquisition within Modicon X80 automation platforms.\u003c\/p\u003e\n\u003ch3\u003e\nHardware Specifications\n\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable class=\"product-specs\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\nParameter\n\u003c\/th\u003e\n\u003cth\u003e\nSpecification\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nModel\n\u003c\/td\u003e\n\u003ctd\u003e\nBMEAHI0812\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nBrand\n\u003c\/td\u003e\n\u003ctd\u003e\nSchneider Electric\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nOrigin\n\u003c\/td\u003e\n\u003ctd\u003e\nUS\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nProduct Type\n\u003c\/td\u003e\n\u003ctd\u003e\nAnalog input module\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nSeries\n\u003c\/td\u003e\n\u003ctd\u003e\nModicon X80\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nInput Channels\n\u003c\/td\u003e\n\u003ctd\u003e\n8 analog inputs\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nOutput Channels\n\u003c\/td\u003e\n\u003ctd\u003e\n4 analog outputs\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nSignal Type\n\u003c\/td\u003e\n\u003ctd\u003e\n4-20 mA current input\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nHART Support\n\u003c\/td\u003e\n\u003ctd\u003e\nApplication specific I\/O with HART function\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nInput Resolution\n\u003c\/td\u003e\n\u003ctd\u003e\n15 bits + sign\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nIsolation\n\u003c\/td\u003e\n\u003ctd\u003e\nChannel isolated\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nInput Impedance\n\u003c\/td\u003e\n\u003ctd\u003e\n250 Ohm internal protective resistor\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nMeasurement Error\n\u003c\/td\u003e\n\u003ctd\u003e\n0.15 % of full scale at 25 deg C; \u0026lt;= 0.3 % of full scale at 0 to 60 deg C\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nTemperature Drift\n\u003c\/td\u003e\n\u003ctd\u003e\n50 ppm\/deg C\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nIsolation Voltage\n\u003c\/td\u003e\n\u003ctd\u003e\n1000 V DC for 60 s between channels; 1400 V DC for 60 s between channels and ground; 1400 V DC for 60 s between channels and bus\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nElectrical Connection\n\u003c\/td\u003e\n\u003ctd\u003e\n20-way terminal block, Telefast compatible\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nProtective Treatment\n\u003c\/td\u003e\n\u003ctd\u003e\nConformal coating\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nWeight\n\u003c\/td\u003e\n\u003ctd\u003e\n0.233 kg\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nOperating Temp\n\u003c\/td\u003e\n\u003ctd\u003e\n0 to 60 deg C\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nPower Consumption\n\u003c\/td\u003e\n\u003ctd\u003e\nNot specified in supplied documentation\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nProtection Rating\n\u003c\/td\u003e\n\u003ctd\u003e\nIP20\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nCompatible Controllers\n\u003c\/td\u003e\n\u003ctd\u003e\nBMEP58... processor, BMECRA31210 head module\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nCompatible Backplane\n\u003c\/td\u003e\n\u003ctd\u003e\nBMEXBP... backplane\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\nModicon X80 Firmware and Backplane Integration\n\u003c\/h3\u003e\n\u003cp\u003eThe BMEAHI0812 module is designed for integration into Modicon X80 common module architecture used with Modicon M580 and M340 Programmable Automation Controllers. The module communicates through the X80 backplane and supports I\/O mapping functions for controller data exchange.\u003c\/p\u003e\n\u003cp\u003eThe hardware design supports I\/O density scaling within the X80 rack structure. Firmware flash compatibility must be maintained with the installed module revision and supported controller configuration. Backplane communication behavior is defined by the Modicon X80 system architecture.\u003c\/p\u003e\n\u003cp\u003eThe module supports isolated analog measurement paths to reduce channel interaction during multi-loop current signal acquisition. The isolated input design provides separation between field signal wiring and internal system communication paths.\u003c\/p\u003e\n\u003ch3\u003e\nFrequently Asked Questions\n\u003c\/h3\u003e\n\u003cp\u003eQ: What type of field signals can the BMEAHI0812 process?\r\nA: The module processes 4-20 mA analog current input signals through 8 isolated input channels and supports HART application specific I\/O functions.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module provide channel isolation?\r\nA: Yes. The BMEAHI0812 provides isolation between channels and specified isolation barriers between channels, ground, and bus.\u003c\/p\u003e\n\u003cp\u003eQ: Which terminal connection method is used for field wiring?\r\nA: The module uses a 20-way terminal block connection and supports Telefast connection accessories.\u003c\/p\u003e\n\u003ch3\u003e\nField Installation Guidelines\n\u003c\/h3\u003e\n\u003cp\u003eInstall the module on a compatible Modicon X80 backplane and verify controller compatibility before commissioning.\u003c\/p\u003e\n\u003cp\u003eUse shielded signal wiring for analog current loops where required by the installation design. Connect cable shields according to site grounding practices to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eSeparate analog signal cables from high-current power conductors and switching circuits. Maintain proper terminal identification during field wiring to prevent channel assignment errors.\u003c\/p\u003e\n\u003cp\u003eVerify terminal block seating, backplane engagement, and module locking position before applying system power. Confirm firmware compatibility between the module and controller configuration during maintenance activities.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52762317324573,"sku":"BMEAHI0812","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMEAHI0812-2_1000.jpg?v=1787223144","url":"https:\/\/www.6gcontrols.com\/products\/schneider-electric-bmeahi0812-analog-input-module","provider":"6G Controls","version":"1.0","type":"link"}