{"product_id":"schneider-electric-bmep582040s-modicon-m580-safety-processor","title":"Schneider Electric BMEP582040S Modicon M580 Safety Processor","description":"\u003cp\u003eConfigured for safety control execution and Ethernet-based remote I\/O communication in the Modicon M580 platform, the \u003cstrong\u003eSchneider Electric BMEP582040S\u003c\/strong\u003e (\u003cstrong\u003eBMEP582040S\u003c\/strong\u003e Safety Processor) provides processor, safety memory, Ethernet service, and remote I\/O network functions through the M580 rack.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMEP582040S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eStandalone Safety Processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon M580\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.849 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e64 x 130 x 135 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e295 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Supply\u003c\/td\u003e\n\u003ctd\u003eInternal power supply via rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Racks\u003c\/td\u003e\n\u003ctd\u003eUp to 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote I\/O Stations\u003c\/td\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Discrete I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e2048 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Analog I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e512 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistributed Equipment\u003c\/td\u003e\n\u003ctd\u003eUp to 64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIP Safety I\/O Devices\u003c\/td\u003e\n\u003ctd\u003eUp to 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interfaces\u003c\/td\u003e\n\u003ctd\u003e1 service port, 2 device network ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Interface\u003c\/td\u003e\n\u003ctd\u003e1 USB Type Mini-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Process RAM\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Process RAM\u003c\/td\u003e\n\u003ctd\u003e768 kB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Memory\u003c\/td\u003e\n\u003ctd\u003e10 kB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Program Memory\u003c\/td\u003e\n\u003ctd\u003e2 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Data Memory\u003c\/td\u003e\n\u003ctd\u003e512 kB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Storage\u003c\/td\u003e\n\u003ctd\u003e4 GB expandable flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Services\u003c\/td\u003e\n\u003ctd\u003eDIO scanner, RIO scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Tasks\u003c\/td\u003e\n\u003ctd\u003e128 event tasks, 2 auxiliary tasks, 1 cyclic\/periodic master task, 1 periodic fast task, 1 periodic safe task\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing Performance\u003c\/td\u003e\n\u003ctd\u003e30 Kinst\/ms at 65% Boolean and 35% fixed arithmetic; 40 Kinst\/ms at 100% Boolean\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e3 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e15 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% without condensation at 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 m; 2000 to 5000 m with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Level\u003c\/td\u003e\n\u003ctd\u003eSIL 3 IEC 61508, SIL 3 IEC 61511, SILCL 3 IEC 62061, SILCL 3 ISO 13849-1 Category 4, SIL 4 EN 50126, EN 50128, EN 50129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, RCM, EAC, UKCA, TÜV, ATEX Zone 2\/22, IECEx Zone 2\/22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e775000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Software\u003c\/td\u003e\n\u003ctd\u003eEcoStruxure Control Expert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eM580 Ethernet and I\/O Architecture\u003c\/h3\u003e\n\u003cp\u003eThe BMEP582040S provides one Ethernet TCP\/IP service port and two Ethernet TCP\/IP device network ports. The two device ports support the remote I\/O network for M580 remote drops. The processor supports up to 8 remote I\/O stations, 64 distributed devices, and 16 CIP Safety I\/O devices.\u003c\/p\u003e\n\u003cp\u003eLocal processing capacity includes up to 2048 discrete I\/O and 512 analog I\/O. Supported application-specific functions include counter processing, motion control, SSI encoder handling, accurate time stamping, serial link functions, and HART communication.\u003c\/p\u003e\n\u003cp\u003eThe processor includes separate process and safety memory areas. Memory consists of 8 MB program RAM, 768 kB process data RAM, 10 kB system memory, 2 MB safety program memory, 512 kB safety data memory, and 4 GB expandable flash storage.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the BMEP582040S powered in the M580 rack?\u003cbr\u003eA: The processor receives its operating power from the rack internal power supply. The specified current consumption is 295 mA at 24 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: How many Ethernet interfaces are provided?\u003cbr\u003eA: The module has one Ethernet TCP\/IP service port and two Ethernet TCP\/IP device network ports. The device network ports support the remote I\/O network.\u003c\/p\u003e\n\u003cp\u003eQ: What are the installation positions for the processor?\u003cbr\u003eA: The CPU is installed in the rack slots marked 00 and 01. Two screws on the top of the CPU secure the module to the rack.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the BMEP582040S in the designated M580 rack CPU positions and secure the module using the specified top mounting screws. Verify that the rack backplane is correctly installed before applying power.\u003c\/p\u003e\n\u003cp\u003eConnect the Ethernet service port and device network ports according to the M580 network architecture. Keep Ethernet communication wiring separated from high-voltage power conductors and high-current switching circuits where practical.\u003c\/p\u003e\n\u003cp\u003eFor shielded communication cables, terminate the shield according to the applicable M580 installation and EMC requirements. Avoid routing communication cables alongside motor power or switching cables for extended distances.\u003c\/p\u003e\n\u003cp\u003eThe module is IP20 rated and conformal coated. The enclosure and cabinet should therefore provide the required protection against direct contact, conductive contamination, condensation, and mechanical damage.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, verify the RUN, ERR, I\/O, DL, BACKUP, ETH MS, ETH NS, SRUN, SMOD, and FORCED IO indicators. Confirm the processor configuration and safety application using EcoStruxure Control Expert before placing the controller into service.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52987848360221,"sku":"BMEP582040S","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMEP582040S2.jpg?v=1789888566","url":"https:\/\/www.6gcontrols.com\/products\/schneider-electric-bmep582040s-modicon-m580-safety-processor","provider":"6G Controls","version":"1.0","type":"link"}