{"product_id":"schneider-electric-bmep584040s-modicon-m580-processor-module","title":"Schneider Electric BMEP584040S Modicon M580 Processor Module","description":"\u003cp\u003eConfigured for safety and process control in the Modicon M580 platform, the \u003cstrong\u003eSchneider Electric BMEP584040S\u003c\/strong\u003e (\u003cstrong\u003eBMEP584040S\u003c\/strong\u003e processor module) provides processor execution, Ethernet device communication, local and remote I\/O management, and CIP Safety device processing. It supports up to 8 racks, 16 remote I\/O stations, 64 distributed devices, and 64 CIP Safety I\/O devices.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMEP584040S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon M580\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProcessor module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.849 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e9.921 x 7.008 x 3.504 in (package dimensions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e295 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003eInternal power supply via rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Capacity\u003c\/td\u003e\n\u003ctd\u003e8 racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Discrete I\/O\u003c\/td\u003e\n\u003ctd\u003e4096 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Analog I\/O\u003c\/td\u003e\n\u003ctd\u003e1024 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Application-Specific Channels\u003c\/td\u003e\n\u003ctd\u003e144\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote I\/O Stations\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistributed Equipment\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIP Safety I\/O Devices\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Connections\u003c\/td\u003e\n\u003ctd\u003e1 service port + 2 device network ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Connection\u003c\/td\u003e\n\u003ctd\u003e1 USB mini-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory\u003c\/td\u003e\n\u003ctd\u003e16 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Memory\u003c\/td\u003e\n\u003ctd\u003e2048 kB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Program Memory\u003c\/td\u003e\n\u003ctd\u003e4 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Data Memory\u003c\/td\u003e\n\u003ctd\u003e1024 kB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Storage\u003c\/td\u003e\n\u003ctd\u003e4 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstruction Processing\u003c\/td\u003e\n\u003ctd\u003e30 Kinst\/ms at 65% Boolean + 35% fixed arithmetic; 40 Kinst\/ms at 100% Boolean\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Services\u003c\/td\u003e\n\u003ctd\u003eRIO scanner, DIO scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Module Capacity\u003c\/td\u003e\n\u003ctd\u003e16 AS-Interface modules, 4 Ethernet communication modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eConformal coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e3 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e15 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% at 55 deg C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 m; 2000 to 5000 m with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Level\u003c\/td\u003e\n\u003ctd\u003eSIL 3 IEC 61508\/IEC 61511; SILCL 3 IEC 62061 and ISO 13849-1 Category 4; SIL 4 EN 50126\/EN 50128\/EN 50129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, RCM, EAC, ATEX Zone 2\/22, IECEx Zone 2\/22, TÜV, UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCybersecurity Functions\u003c\/td\u003e\n\u003ctd\u003eDoS prevention, IPSec, SNMP logging, Syslog, audit trail, embedded firewall, firmware signature, password protection, port hardening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eM580 Ethernet and I\/O Processing\u003c\/h3\u003e\n\u003cp\u003eThe BMEP584040S uses Ethernet TCP\/IP interfaces for service and device-network communication. The processor manages RIO and DIO scanning and supports distributed equipment and CIP Safety I\/O devices. Local processing capacity is specified at 4096 discrete I\/O and 1024 analog I\/O, with up to 144 application-specific local channels.\u003c\/p\u003e\n\u003cp\u003eApplication-specific functions include counter processing, motion control, SSI encoder interfaces, accurate time stamping, serial links, and HART communication. The processor provides separate program, process data, safety program, and safety data memory areas.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the BMEP584040S powered?\u003c\/p\u003e\n\u003cp\u003eA: The module receives its operating power through the Modicon M580 rack backplane. The specified current consumption is 295 mA at 24 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: What Ethernet connections are provided?\u003c\/p\u003e\n\u003cp\u003eA: The processor has one Ethernet TCP\/IP service port and two Ethernet TCP\/IP device-network ports. A USB mini-B interface is also provided for integrated connections.\u003c\/p\u003e\n\u003cp\u003eQ: What I\/O and safety device capacity is specified?\u003c\/p\u003e\n\u003cp\u003eA: The processor supports up to 4096 local discrete I\/O, 1024 local analog I\/O, 16 remote I\/O stations, 64 distributed devices, and 64 CIP Safety I\/O devices.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the processor in the specified Modicon M580 rack position and verify correct mechanical engagement with the backplane.\u003c\/li\u003e\n\u003cli\u003eConfirm that the rack power system can supply the processor and all connected modules within the applicable load limits.\u003c\/li\u003e\n\u003cli\u003eRoute Ethernet communication wiring separately from high-current switching and power conductors where practical to reduce electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shields according to the applicable M580 installation and plant grounding design. Avoid creating unintended shield current paths.\u003c\/li\u003e\n\u003cli\u003eVerify Ethernet port assignment before connecting service and device-network cables.\u003c\/li\u003e\n\u003cli\u003eCheck RUN, ERR, I\/O, DL, BACKUP, Ethernet, SRUN, SMOD, and FORCED IO indicators during commissioning.\u003c\/li\u003e\n\u003cli\u003eUse the specified environmental limits when locating the rack. The module is IP20 and requires an enclosure providing the required environmental protection.\u003c\/li\u003e\n\u003cli\u003eFor safety applications, verify the configured safety architecture, firmware compatibility, wiring, diagnostics, and safety validation procedure against the applicable M580 safety documentation before placing the system into service.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52997824282909,"sku":"BMEP584040S","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMEP584040S2.jpg?v=1789954882","url":"https:\/\/www.6gcontrols.com\/products\/schneider-electric-bmep584040s-modicon-m580-processor-module","provider":"6G Controls","version":"1.0","type":"link"}