{"product_id":"schneider-electric-bmxami0410h-modicon-x80-analog-input-module","title":"Schneider Electric BMXAMI0410H Modicon X80 Analog Input Module","description":"\u003cp\u003eConfigured for isolated analog signal acquisition in the Modicon X80 platform, the \u003cstrong\u003eSchneider Electric BMXAMI0410H\u003c\/strong\u003e (\u003cstrong\u003eBMXAMI0410H\u003c\/strong\u003e analog input module) provides four high-level input channels for current and voltage measurement. It supports 16-bit analog resolution, channel isolation, conformal coating, and direct connection through a 20-way connector.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXAMI0410H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog input module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eIsolated high-level analog input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input\u003c\/td\u003e\n\u003ctd\u003e+\/- 20 mA, 0...20 mA, 4...20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input\u003c\/td\u003e\n\u003ctd\u003e+\/- 10 V, +\/- 5 V, 0...10 V, 0...5 V, 1...5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Resolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Conversion\u003c\/td\u003e\n\u003ctd\u003e24 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Resolution\u003c\/td\u003e\n\u003ctd\u003e0.92 uA for current ranges; 0.35 mV for voltage ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 MOhm voltage mode; 250 Ohm + 3.6...50 Ohm internal protective resistor current mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003e300 VDC between channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation to Ground\u003c\/td\u003e\n\u003ctd\u003e1400 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation to Bus\u003c\/td\u003e\n\u003ctd\u003e1400 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrosstalk Attenuation\u003c\/td\u003e\n\u003ctd\u003eMinimum 80 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e90 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Cycle\u003c\/td\u003e\n\u003ctd\u003e1 ms + 1 ms x number of channels used, fast read\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Read Cycle\u003c\/td\u003e\n\u003ctd\u003e5 ms for 4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Error\u003c\/td\u003e\n\u003ctd\u003e0.15% of full scale for current inputs at 25 deg C; 0.075% of full scale for voltage inputs at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Error\u003c\/td\u003e\n\u003ctd\u003eUp to 0.55% of full scale for current inputs and 0.2% of full scale for voltage inputs over -25...70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.82 W typical \/ 1.30 W maximum at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e45 mA at 24 VDC; 150 mA at 3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e20-way connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25...70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40...85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5...95% at 55 deg C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e3 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e30 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.143 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, RCM, CSA, EAC, Merchant Navy, UL, ATEX, IEC-Ex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-2-201, IEC 61131-2, UL 61010-2-201, CSA C22.2 No 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Analog Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe BMXAMI0410H uses isolated input channels to separate analog measurement circuits from each other and from the Modicon X80 bus. The module accepts both current and voltage signal ranges, allowing channel configuration for 4-20 mA, 0-20 mA, +\/- 20 mA, 0-10 V, +\/- 10 V, 0-5 V, +\/- 5 V, and 1-5 V signals.\u003c\/p\u003e\n\u003cp\u003eA minimum 80 dB crosstalk attenuation and 90 dB common mode rejection are specified for signal acquisition. The module uses first-order digital filtering and provides a digital value range of -32768 to +32767 in maximum user scale, with +\/-10000 as the default scale.\u003c\/p\u003e\n\u003cp\u003eThe conformal-coated construction is specified for severe environments. Environmental characteristics include gas resistance class Gx and 3C4, dust and sand resistance class 3S4, salt resistance level 2, and mold and fungal-spore resistance class 3B2.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What signal types can the BMXAMI0410H measure?\u003cbr\u003eA: The four channels support +\/- 20 mA, 0...20 mA, 4...20 mA, +\/- 10 V, +\/- 5 V, 0...10 V, 0...5 V, and 1...5 V input ranges.\u003c\/p\u003e\n\u003cp\u003eQ: Are the four analog channels electrically isolated?\u003cbr\u003eA: Yes. The module specifies 300 VDC isolation between channels and 1400 VDC isolation between channels and ground and between channels and the bus.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum power consumption of the module?\u003cbr\u003eA: The specified maximum consumption is 1.30 W at 24 VDC. The typical value is 0.82 W.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in a compatible Modicon X80 rack and connect it through the specified 20-way connector.\u003c\/li\u003e\n\u003cli\u003eVerify the configured input range against the actual field transmitter or voltage source before energizing the channel.\u003c\/li\u003e\n\u003cli\u003eKeep analog signal wiring separated from high-current power and switching conductors to reduce electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eUse appropriate shield termination practices for the installed signal and cabinet grounding design.\u003c\/li\u003e\n\u003cli\u003eConfirm channel isolation requirements when connecting field devices with different reference potentials.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified operating temperature and humidity limits inside the enclosure.\u003c\/li\u003e\n\u003cli\u003eCheck the RUN, channel diagnostic, ERR, and I\/O LEDs during commissioning.\u003c\/li\u003e\n\u003cli\u003eDo not apply input voltages or currents outside the documented overload and conversion limits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52998551634205,"sku":"BMXAMI0410H","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXAMI0410H2.jpg?v=1789961158","url":"https:\/\/www.6gcontrols.com\/products\/schneider-electric-bmxami0410h-modicon-x80-analog-input-module","provider":"6G Controls","version":"1.0","type":"link"}