{"product_id":"schneider-electric-bmxami0810h-modicon-x80-analog-input-module","title":"Schneider Electric BMXAMI0810H Modicon X80 Analog Input Module","description":"\u003cp\u003eConfigured for high-speed analog signal acquisition in the Modicon X80 platform, the \u003cstrong\u003eSchneider Electric BMXAMI0810H\u003c\/strong\u003e (\u003cstrong\u003eBMXAMI0810H\u003c\/strong\u003e analog input module) provides eight isolated current or voltage inputs with 15 bits plus sign resolution, configurable digital filtering, and a fast read cycle for Modicon M580 and M340 PAC systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXAMI0810H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIsolated analog input module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eSevere environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e+\/- 20 mA, 0-20 mA, 4-20 mA, +\/- 10 V, +\/- 5 V, 0-10 V, 0-5 V, 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Level\u003c\/td\u003e\n\u003ctd\u003eHigh level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Isolation\u003c\/td\u003e\n\u003ctd\u003e300 V DC between channels; 1400 V DC between channels and ground; 1400 V DC between channels and bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Conversion\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resolution\u003c\/td\u003e\n\u003ctd\u003e15 bits + sign\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Resolution\u003c\/td\u003e\n\u003ctd\u003e0.36 mV for voltage ranges; 1.4 uA for current ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 MOhm in voltage mode; 250 Ohm + 3.6-50 Ohm protective resistor in current mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFast Read Cycle\u003c\/td\u003e\n\u003ctd\u003e1 ms + 1 ms x number of channels used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Read Cycle\u003c\/td\u003e\n\u003ctd\u003e9 ms for 8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Filter\u003c\/td\u003e\n\u003ctd\u003eFirst order digital filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrosstalk Attenuation\u003c\/td\u003e\n\u003ctd\u003eMinimum 80 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e80 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e300 V DC between channels; 1400 V DC between channels and ground and bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.06 W typical \/ 1.50 W maximum at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e54 mA at 24 V DC; 150 mA at 3.3 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.175 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003ePackage: 5.5 x 11.0 x 11.6 cm; module dimensions not specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e28-way, 1 connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5-95% at 55 deg C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e3 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e30 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0-2000 m; 2000-5000 m with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, RCM, CSA, EAC, Merchant Navy, UL, ATEX, IEC-Ex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-2-201, IEC 61131-2, UL 61010-2-201, CSA C22.2 No 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation and Analog Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe BMXAMI0810H provides eight isolated analog channels for current and voltage measurement. Supported current ranges include +\/- 20 mA, 0-20 mA, and 4-20 mA. Voltage ranges include +\/- 10 V, +\/- 5 V, 0-10 V, 0-5 V, and 1-5 V.\u003c\/p\u003e\n\u003cp\u003eChannel isolation is specified at 300 V DC between channels and 1400 V DC between channels and both ground and the bus. The module provides a minimum 80 dB crosstalk attenuation and 80 dB common mode rejection. These characteristics define the electrical separation and signal rejection available between independently wired analog channels.\u003c\/p\u003e\n\u003cp\u003eThe module uses first-order digital filtering. The fast read cycle is 1 ms plus 1 ms for each channel used, while the nominal read cycle is 9 ms with all eight channels active.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What analog signal ranges can the BMXAMI0810H accept?\u003cbr\u003eA: The module accepts +\/- 20 mA, 0-20 mA, 4-20 mA, +\/- 10 V, +\/- 5 V, 0-10 V, 0-5 V, and 1-5 V input ranges.\u003c\/p\u003e\n\u003cp\u003eQ: What isolation levels are specified for the analog channels?\u003cbr\u003eA: The specification states 300 V DC isolation between channels and 1400 V DC isolation between channels and ground and between channels and the bus.\u003c\/p\u003e\n\u003cp\u003eQ: What is the power consumption of the module?\u003cbr\u003eA: At 24 V DC, power consumption is 1.06 W typical and 1.50 W maximum. Current consumption is 54 mA at 24 V DC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the BMXAMI0810H on the applicable Modicon X80 rack and connect the 28-way field connector according to the module wiring documentation.\u003c\/p\u003e\n\u003cp\u003eRoute analog signal wiring separately from high-voltage power conductors, motor cables, and high-current switching circuits where practical. Maintain the specified channel isolation when connecting signals from electrically independent field devices.\u003c\/p\u003e\n\u003cp\u003eUse shielded instrumentation cable where required by the installation environment. Terminate cable shields according to the control cabinet grounding scheme and avoid creating unintended ground loops.\u003c\/p\u003e\n\u003cp\u003eVerify the selected input range against the actual field transmitter or voltage source before commissioning. For 4-20 mA circuits, confirm loop polarity and current range configuration. For voltage inputs, verify signal reference and common wiring before energizing the channel.\u003c\/p\u003e\n\u003cp\u003eThe BMXAMI0810H has conformal coating and an operating range of -25 to 70 deg C. Installation should nevertheless maintain the environmental conditions specified for the complete Modicon X80 assembly.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52998562545949,"sku":"BMXAMI0810H","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXAMI0810H2.jpg?v=1789962050","url":"https:\/\/www.6gcontrols.com\/products\/schneider-electric-bmxami0810h-modicon-x80-analog-input-module","provider":"6G Controls","version":"1.0","type":"link"}