{"product_id":"schneider-electric-bmxddo6402k-modicon-x80-discrete-output-module","title":"Schneider Electric BMXDDO6402K Modicon X80 Discrete Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMXDDO6402K\u003c\/strong\u003e is a 64-channel discrete transistor output module in the Modicon X80 range. It operates with a 24 VDC output supply and uses positive output logic. The module provides individual channel control, output status detection thresholds, and protection against reverse polarity, external short circuits, overloads, and overvoltage.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Configuration and Operation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXDDO6402K provides 64 transistor output channels for controlling external actuators and other discrete loads. Its positive output logic determines the output switching arrangement. The specified output response time is 1.2 ms, which defines the delay between an output command and the corresponding output response.\u003c\/p\u003e\n\u003cp\u003eThe module supports output paralleling, with a maximum of three outputs. This configuration must follow the manufacturer's channel and load restrictions. The specified switching frequency is expressed as 0.5\/LI² Hz, so the applicable load inductance and current conditions should be checked before selecting a switching rate.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Protection and Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe output circuits include reverse-polarity, external short-circuit, overload, and overvoltage protection. An external fuse is also specified as part of the protection arrangement. These functions address electrical faults that can occur in field wiring and connected loads.\u003c\/p\u003e\n\u003cp\u003eThe module provides voltage detection thresholds for preactuator fault monitoring. A voltage below 14 VDC indicates a preactuator fault, while a voltage above 18 VDC is specified for preactuator detection at state 0. These thresholds are relevant when checking output-side voltage conditions during troubleshooting.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXDDO6402K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Transistor Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Technology\u003c\/td\u003e\n\u003ctd\u003eSolid-state transistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Logic\u003c\/td\u003e\n\u003ctd\u003ePositive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19-30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current per Channel\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Module\u003c\/td\u003e\n\u003ctd\u003e6.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e1.2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Parallel Outputs\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Overload Duration\u003c\/td\u003e\n\u003ctd\u003e15 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd\u003e0.5\/LI² Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Ohmic Load Impedance\u003c\/td\u003e\n\u003ctd\u003e220 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Detection Threshold\u003c\/td\u003e\n\u003ctd\u003eBelow 14 VDC: preactuator fault; above 18 VDC: preactuator at state 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003eGreater than 10 MOhm at 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1500 VAC, 50\/60 Hz, 1 min (output\/ground and output\/internal logic); 500 VDC, 1 min (between channel groups)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eReverse polarity, short circuit, overload and overvoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired External Fuse\u003c\/td\u003e\n\u003ctd\u003e2 A fast-blow fuse per 16-channel group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eStandard version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e150,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3595863910490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXDDO6402K belongs to the Modicon X80 common I\/O platform, which is used with Modicon M340 and M580 programmable automation controllers. Its 64-channel configuration provides a high-density discrete output interface for rack-based control systems.\u003c\/p\u003e\n\u003cp\u003eThe module uses two 40-pin connectors for field output connections. The 64 channels are arranged in four groups of 16, with an external 2 A fast-blow fuse specified for each group. This grouping is important when planning field wiring and fault isolation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the rated output current of the BMXDDO6402K?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The rated output current is 0.1 A per channel, with a maximum aggregate module current of 6.4 A. The total load must remain within the module limit even when multiple channels operate simultaneously.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the BMXDDO6402K drive inductive loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module supports transistor output switching, but the permissible switching frequency depends on load inductance and current. The specified frequency relationship is 0.5\/LI² Hz. Check the load characteristics and manufacturer's switching limits before application.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What external protection is required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: A 2 A fast-blow fuse is specified for each 16-channel group. The module also incorporates electronic overload, short-circuit, reverse-polarity and overvoltage protection.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68109415907613,"sku":"BMXDDO6402K","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXDDO6402K2.jpg?v=1794907535","url":"https:\/\/www.6gcontrols.com\/products\/schneider-electric-bmxddo6402k-modicon-x80-discrete-output-module","provider":"6G Controls","version":"1.0","type":"link"}