{"product_id":"woodward-5466-411-micronet-ethernet-communication-module","title":"Woodward 5466-411 MicroNet Ethernet Communication Module","description":"\u003ch3\u003e\n\u003cstrong\u003eOverview\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e5466-411\u003c\/strong\u003e Ethernet module is a dedicated communication interface engineered for Woodward MicroNet™ digital control platforms. It enables deterministic, high-speed Ethernet data transfer between the primary CPU chassis and distributed remote terminal (RTN) expansion chassis, supporting scalable and fault-tolerant control system architectures.\u003c\/p\u003e\n\u003cp\u003eDesigned for continuous operation in demanding industrial environments, this module plays a critical role in maintaining real-time data integrity across distributed control networks commonly used in turbine and power management systems.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eCore Functionality\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e5466-411\u003c\/strong\u003e module acts as a chassis-level Ethernet bridge, facilitating internal system communication rather than external plant networking. It is optimized for reliable CPU-to-remote chassis data exchange and is not intended to function as a general-purpose Ethernet switch or gateway.\u003c\/p\u003e\n\u003cp\u003eKey operational capabilities include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\nDeterministic Ethernet communication within MicroNet and MicroNet Plus systems\n\u003c\/li\u003e\n\u003cli\u003e\nStable data synchronization between controller CPUs and RTN expansion racks\n\u003c\/li\u003e\n\u003cli\u003e\nStatus monitoring via onboard LED indicators for link and activity diagnostics\n\u003c\/li\u003e\n\u003cli\u003e\nSingle RJ45 Ethernet interface designed for internal control network topology\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\nModule supply voltage: 5.0 VDC ±5% (supplied by MicroNet chassis backplane)\n\u003c\/li\u003e\n\u003cli\u003e\nPower consumption optimized for continuous operation\n\u003c\/li\u003e\n\u003cli\u003e\nElectrical isolation handled at system level within the MicroNet chassis\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNote: Some distributor listings reference 110 VAC or 125 VDC; these values apply to the overall control system power input, not to the \u003cstrong\u003e5466-411\u003c\/strong\u003e module itself.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\nForm factor: Panel-mounted control module\n\u003c\/li\u003e\n\u003cli\u003e\nEthernet interface: Single RJ45 port\n\u003c\/li\u003e\n\u003cli\u003e\nStatus indicators: Integrated LEDs for communication state\n\u003c\/li\u003e\n\u003cli\u003e\nDimensions: 95 × 105 × 100 mm\n\u003c\/li\u003e\n\u003cli\u003e\nWeight: 1.40 lbs\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eCompliance and Documentation\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e5466-411\u003c\/strong\u003e is manufactured in accordance with multiple international marine and industrial standards, including ABS, CSA, CE (EMC), and LRS approvals.\u003c\/p\u003e\n\u003cp\u003eInstallation, handling precautions, and system integration guidelines are documented in Woodward Application Note 51192, which should be consulted prior to deployment.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThis Ethernet communication module is commonly installed in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\nMicroNet and MicroNet Plus turbine control systems\n\u003c\/li\u003e\n\u003cli\u003e\nDistributed gas and steam turbine control architectures\n\u003c\/li\u003e\n\u003cli\u003e\nPower generation and energy management platforms\n\u003c\/li\u003e\n\u003cli\u003e\nControl systems requiring deterministic CPU-to-remote rack communication\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eFAQ\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 5466-411 used for external Ethernet networking?\u003c\/strong\u003e\r\nA: No. This module is intended for internal MicroNet system communication between main CPU chassis and RTN expansion chassis only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module require a separate power supply?\u003c\/strong\u003e\r\nA: No. The module receives regulated 5 VDC directly from the MicroNet backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it be used outside MicroNet systems?\u003c\/strong\u003e\r\nA: No. The \u003cstrong\u003e5466-411\u003c\/strong\u003e is specifically designed for Woodward MicroNet and MicroNet Plus control platforms.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52762056360221,"sku":"5466-411","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/5466-411-2_1000.jpg?v=1787222376","url":"https:\/\/www.6gcontrols.com\/products\/woodward-5466-411-micronet-ethernet-communication-module","provider":"6G Controls","version":"1.0","type":"link"}