{"product_id":"yokogawa-zr402g-t-e-e-a-hs-sct-separate-type-zirconia-oxygen-analyzer","title":"Yokogawa ZR402G-T-E-E-A\/HS\/SCT Separate Type Zirconia Oxygen Analyzer","description":"\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003ch3\u003e\nOverview\n\u003c\/h3\u003e\n\u003cp data-start=\"18\" data-end=\"435\"\u003e\nThe \u003cstrong data-start=\"22\" data-end=\"56\"\u003eYokogawa ZR402G-T-E-E-A\/HS\/SCT\u003c\/strong\u003e is a high-performance, separate-type Zirconia Oxygen Analyzer. It measures oxygen concentration in combustion gases, enhancing efficiency and combustion control in various industrial applications. This analyzer ensures precise monitoring in environments such as boilers, furnaces, and incinerators, offering a quick response time and versatile outputs for efficient integration.\n\u003c\/p\u003e\n\u003ch3 data-start=\"437\" data-end=\"469\"\u003e\n\u003cstrong data-start=\"441\" data-end=\"469\"\u003eTechnical Specifications\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-start=\"471\" data-end=\"1691\" data-is-only-node=\"\" data-is-last-node=\"\"\u003e\n\u003cli data-start=\"471\" data-end=\"512\"\u003e\n\u003cstrong data-start=\"473\" data-end=\"489\"\u003eModel Number\u003c\/strong\u003e: ZR402G-T-E-E-A\/HS\/SCT\n\u003c\/li\u003e\n\u003cli data-start=\"513\" data-end=\"563\"\u003e\n\u003cstrong data-start=\"515\" data-end=\"523\"\u003eType\u003c\/strong\u003e: Separate Type Zirconia Oxygen Analyzer\n\u003c\/li\u003e\n\u003cli data-start=\"564\" data-end=\"605\"\u003e\n\u003cstrong data-start=\"566\" data-end=\"587\"\u003eMeasurement Range\u003c\/strong\u003e: 0.01–100 vol% O₂\n\u003c\/li\u003e\n\u003cli data-start=\"606\" data-end=\"683\"\u003e\n\u003cstrong data-start=\"608\" data-end=\"633\"\u003eMeasurement Principle\u003c\/strong\u003e: Zirconia sensor based on oxygen ion conductivity\n\u003c\/li\u003e\n\u003cli data-start=\"684\" data-end=\"734\"\u003e\n\u003cstrong data-start=\"686\" data-end=\"703\"\u003eResponse Time\u003c\/strong\u003e: 90% response within 5 seconds\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"796\"\u003e\n\u003cstrong data-start=\"737\" data-end=\"754\"\u003eOutput Signal\u003c\/strong\u003e: 4–20 mA DC, HART communication supported\n\u003c\/li\u003e\n\u003cli data-start=\"797\" data-end=\"868\"\u003e\n\u003cstrong data-start=\"799\" data-end=\"824\"\u003eContact Output Signal\u003c\/strong\u003e: Four points (one fail-safe, normally open)\n\u003c\/li\u003e\n\u003cli data-start=\"869\" data-end=\"900\"\u003e\n\u003cstrong data-start=\"871\" data-end=\"888\"\u003eContact Input\u003c\/strong\u003e: Two points\n\u003c\/li\u003e\n\u003cli data-start=\"901\" data-end=\"955\"\u003e\n\u003cstrong data-start=\"903\" data-end=\"919\"\u003eAnalog Input\u003c\/strong\u003e: One point (thermal input, 4–20 mA)\n\u003c\/li\u003e\n\u003cli data-start=\"956\" data-end=\"1007\"\u003e\n\u003cstrong data-start=\"958\" data-end=\"969\"\u003eDisplay\u003c\/strong\u003e: LCD (320 × 240 dot) with touchscreen\n\u003c\/li\u003e\n\u003cli data-start=\"1008\" data-end=\"1063\"\u003e\n\u003cstrong data-start=\"1010\" data-end=\"1031\"\u003eProtection Rating\u003c\/strong\u003e: IP65 for outdoor installations\n\u003c\/li\u003e\n\u003cli data-start=\"1064\" data-end=\"1107\"\u003e\n\u003cstrong data-start=\"1066\" data-end=\"1091\"\u003eOperating Temperature\u003c\/strong\u003e: -10°C to +55°C\n\u003c\/li\u003e\n\u003cli data-start=\"1108\" data-end=\"1149\"\u003e\n\u003cstrong data-start=\"1110\" data-end=\"1133\"\u003eAmbient Temperature\u003c\/strong\u003e: -20°C to +55°C\n\u003c\/li\u003e\n\u003cli data-start=\"1150\" data-end=\"1191\"\u003e\n\u003cstrong data-start=\"1152\" data-end=\"1175\"\u003eStorage Temperature\u003c\/strong\u003e: -30°C to +70°C\n\u003c\/li\u003e\n\u003cli data-start=\"1192\" data-end=\"1244\"\u003e\n\u003cstrong data-start=\"1194\" data-end=\"1214\"\u003eAmbient Humidity\u003c\/strong\u003e: 0 to 95% RH (non-condensing)\n\u003c\/li\u003e\n\u003cli data-start=\"1245\" data-end=\"1323\"\u003e\n\u003cstrong data-start=\"1247\" data-end=\"1271\"\u003ePower Supply Voltage\u003c\/strong\u003e: 100 to 240 V AC (acceptable range: 85 to 264 V AC)\n\u003c\/li\u003e\n\u003cli data-start=\"1324\" data-end=\"1389\"\u003e\n\u003cstrong data-start=\"1326\" data-end=\"1347\"\u003ePower Consumption\u003c\/strong\u003e: Max. 300 W, approx. 100 W for normal use\n\u003c\/li\u003e\n\u003cli data-start=\"1390\" data-end=\"1469\"\u003e\n\u003cstrong data-start=\"1392\" data-end=\"1413\"\u003eWiring Connection\u003c\/strong\u003e: G1\/2, Pg 13.5, M20 × 1.5, 1\/2 NPT (with plug), 8 holes\n\u003c\/li\u003e\n\u003cli data-start=\"1470\" data-end=\"1519\"\u003e\n\u003cstrong data-start=\"1472\" data-end=\"1488\"\u003eInstallation\u003c\/strong\u003e: Panel, wall, or pipe mounting\n\u003c\/li\u003e\n\u003cli data-start=\"1520\" data-end=\"1555\"\u003e\n\u003cstrong data-start=\"1522\" data-end=\"1539\"\u003eCase Material\u003c\/strong\u003e: Aluminum alloy\n\u003c\/li\u003e\n\u003cli data-start=\"1556\" data-end=\"1609\"\u003e\n\u003cstrong data-start=\"1558\" data-end=\"1573\"\u003ePaint Color\u003c\/strong\u003e: Silver gray (Munsell 3.2PB7.4\/1.2)\n\u003c\/li\u003e\n\u003cli data-start=\"1610\" data-end=\"1664\"\u003e\n\u003cstrong data-start=\"1612\" data-end=\"1622\"\u003eFinish\u003c\/strong\u003e: Polyurethane corrosion-resistant coating\n\u003c\/li\u003e\n\u003cli data-start=\"1665\" data-end=\"1691\" data-is-last-node=\"\"\u003e\n\u003cstrong data-start=\"1667\" data-end=\"1677\"\u003eWeight\u003c\/strong\u003e: 6 kg\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"0\" data-end=\"106\"\u003e\nNew Arrivals\n\u003c\/h3\u003e\n\u003cdiv class=\"overflow-x-auto contain-inline-size\"\u003e\n\u003ctable class=\"product-specs\" data-start=\"108\" data-end=\"11626\"\u003e\n\u003cthead data-start=\"108\" data-end=\"207\"\u003e\n\u003ctr data-start=\"108\" data-end=\"207\"\u003e\n\u003cth data-start=\"108\" data-end=\"128\"\u003e\n\u003cstrong data-start=\"110\" data-end=\"119\"\u003eBrand\u003c\/strong\u003e\n\u003c\/th\u003e\n\u003cth data-start=\"128\" data-end=\"155\"\u003e\n\u003cstrong data-start=\"130\" data-end=\"139\"\u003eModel\u003c\/strong\u003e\n\u003c\/th\u003e\n\u003cth data-start=\"155\" data-end=\"185\"\u003e\n\u003cstrong data-start=\"157\" data-end=\"172\"\u003eDescription\u003c\/strong\u003e\n\u003c\/th\u003e\n\u003cth data-start=\"185\" data-end=\"207\"\u003e\n\u003cstrong data-start=\"187\" data-end=\"205\"\u003eStock Quantity\u003c\/strong\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"308\" data-end=\"11626\"\u003e\n\u003ctr data-start=\"308\" data-end=\"407\"\u003e\n\u003ctd\u003e\nCrompton\n\u003c\/td\u003e\n\u003ctd\u003e\n256-PLLW\n\u003c\/td\u003e\n\u003ctd\u003e\nPressure Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"408\" data-end=\"507\"\u003e\n\u003ctd\u003e\nCrompton\n\u003c\/td\u003e\n\u003ctd\u003e\n256-PAS\n\u003c\/td\u003e\n\u003ctd\u003e\nPressure Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"508\" data-end=\"607\"\u003e\n\u003ctd\u003e\nBROYCE\n\u003c\/td\u003e\n\u003ctd\u003e\nB1DO\n\u003c\/td\u003e\n\u003ctd\u003e\nDigital Output Module\n\u003c\/td\u003e\n\u003ctd\u003e\n5\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"608\" data-end=\"707\"\u003e\n\u003ctd\u003e\nBROYCE\n\u003c\/td\u003e\n\u003ctd\u003e\nB1DO-WT\n\u003c\/td\u003e\n\u003ctd\u003e\nDigital Output Module (WT)\n\u003c\/td\u003e\n\u003ctd\u003e\n8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"708\" data-end=\"807\"\u003e\n\u003ctd\u003e\nDUNGS\n\u003c\/td\u003e\n\u003ctd\u003e\nSV-DLE512\n\u003c\/td\u003e\n\u003ctd\u003e\nValve Actuator\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"808\" data-end=\"908\"\u003e\n\u003ctd\u003e\nSPIRAX SARCO\n\u003c\/td\u003e\n\u003ctd\u003e\nEP5\n\u003c\/td\u003e\n\u003ctd\u003e\nElectronic Pressure Switch\n\u003c\/td\u003e\n\u003ctd\u003e\n5\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"909\" data-end=\"1008\"\u003e\n\u003ctd\u003e\nWatts\n\u003c\/td\u003e\n\u003ctd\u003e\nR119-06C\/M2\n\u003c\/td\u003e\n\u003ctd\u003e\nPressure Regulator\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1009\" data-end=\"1108\"\u003e\n\u003ctd\u003e\nCCS\n\u003c\/td\u003e\n\u003ctd\u003e\n604VM1\n\u003c\/td\u003e\n\u003ctd\u003e\nValve Actuator\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1109\" data-end=\"1208\"\u003e\n\u003ctd\u003e\nHand Valve\n\u003c\/td\u003e\n\u003ctd\u003e\nKVH400-04\n\u003c\/td\u003e\n\u003ctd\u003e\nControl Valve\n\u003c\/td\u003e\n\u003ctd\u003e\n10\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1209\" data-end=\"1308\"\u003e\n\u003ctd\u003e\nPanasonic\n\u003c\/td\u003e\n\u003ctd\u003e\nTH2385\n\u003c\/td\u003e\n\u003ctd\u003e\nTemperature Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1309\" data-end=\"1408\"\u003e\n\u003ctd\u003e\nSCHROEDER\n\u003c\/td\u003e\n\u003ctd\u003e\nNF301NNS7SD5\n\u003c\/td\u003e\n\u003ctd\u003e\nFilter Control\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1409\" data-end=\"1508\"\u003e\n\u003ctd\u003e\nITT\n\u003c\/td\u003e\n\u003ctd\u003e\n132P4S185\n\u003c\/td\u003e\n\u003ctd\u003e\nPressure Switch\n\u003c\/td\u003e\n\u003ctd\u003e\n8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1509\" data-end=\"1608\"\u003e\n\u003ctd\u003e\nITT\n\u003c\/td\u003e\n\u003ctd\u003e\n160P4S43\n\u003c\/td\u003e\n\u003ctd\u003e\nPressure Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n5\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1609\" data-end=\"1708\"\u003e\n\u003ctd\u003e\nITT\n\u003c\/td\u003e\n\u003ctd\u003e\n160P4S36\n\u003c\/td\u003e\n\u003ctd\u003e\nPressure Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1709\" data-end=\"1808\"\u003e\n\u003ctd\u003e\nITT\n\u003c\/td\u003e\n\u003ctd\u003e\n180P44C6\n\u003c\/td\u003e\n\u003ctd\u003e\nPressure Switch\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1809\" data-end=\"1908\"\u003e\n\u003ctd\u003e\nTAIYO\n\u003c\/td\u003e\n\u003ctd\u003e\nTAIYO\n\u003c\/td\u003e\n\u003ctd\u003e\nHydraulic Valve\n\u003c\/td\u003e\n\u003ctd\u003e\n10\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1909\" data-end=\"2008\"\u003e\n\u003ctd\u003e\nMETSO\n\u003c\/td\u003e\n\u003ctd\u003e\nND9103HN\n\u003c\/td\u003e\n\u003ctd\u003e\nDiscrete I\/O Module\n\u003c\/td\u003e\n\u003ctd\u003e\n8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2009\" data-end=\"2108\"\u003e\n\u003ctd\u003e\nMETSO\n\u003c\/td\u003e\n\u003ctd\u003e\nND9106HN\n\u003c\/td\u003e\n\u003ctd\u003e\nDiscrete I\/O Module\n\u003c\/td\u003e\n\u003ctd\u003e\n5\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2109\" data-end=\"2208\"\u003e\n\u003ctd\u003e\nMETSO\n\u003c\/td\u003e\n\u003ctd\u003e\nND9106HNT\n\u003c\/td\u003e\n\u003ctd\u003e\nDiscrete I\/O Module\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2209\" data-end=\"2308\"\u003e\n\u003ctd\u003e\nYUKEN\n\u003c\/td\u003e\n\u003ctd\u003e\nLSVG-03-60-10\n\u003c\/td\u003e\n\u003ctd\u003e\nPressure Switch\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2309\" data-end=\"2408\"\u003e\n\u003ctd\u003e\nREXVOTH\n\u003c\/td\u003e\n\u003ctd\u003e\n4WE6D70\/HG24 N9K4\n\u003c\/td\u003e\n\u003ctd\u003e\nValve Actuator\n\u003c\/td\u003e\n\u003ctd\u003e\n5\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2409\" data-end=\"2508\"\u003e\n\u003ctd\u003e\nOILTECH\n\u003c\/td\u003e\n\u003ctd\u003e\nDS307\/SCH\/V2\/G\n\u003c\/td\u003e\n\u003ctd\u003e\nOil System Monitoring\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2509\" data-end=\"2608\"\u003e\n\u003ctd\u003e\nYUKEN\n\u003c\/td\u003e\n\u003ctd\u003e\nPST-02-H-20\n\u003c\/td\u003e\n\u003ctd\u003e\nHydraulic Valve\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2609\" data-end=\"2708\"\u003e\n\u003ctd\u003e\nFISCHER PORTER\n\u003c\/td\u003e\n\u003ctd\u003e\nD358E928U01\n\u003c\/td\u003e\n\u003ctd\u003e\nFlow Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n10\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2709\" data-end=\"2808\"\u003e\n\u003ctd\u003e\nTAKENAKA\n\u003c\/td\u003e\n\u003ctd\u003e\nPHOTO SWITCH\n\u003c\/td\u003e\n\u003ctd\u003e\nPhotoelectric Switch\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2809\" data-end=\"2908\"\u003e\n\u003ctd\u003e\nTAKENAKA\n\u003c\/td\u003e\n\u003ctd\u003e\nDVP16SP11R\n\u003c\/td\u003e\n\u003ctd\u003e\nControl Module\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2909\" data-end=\"3008\"\u003e\n\u003ctd\u003e\nTAKENAKA\n\u003c\/td\u003e\n\u003ctd\u003e\nDVP14SS11T2\n\u003c\/td\u003e\n\u003ctd\u003e\nControl Module\n\u003c\/td\u003e\n\u003ctd\u003e\n8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3009\" data-end=\"3108\"\u003e\n\u003ctd\u003e\nTAKENAKA\n\u003c\/td\u003e\n\u003ctd\u003e\nDVP08SM11N\n\u003c\/td\u003e\n\u003ctd\u003e\nControl Module\n\u003c\/td\u003e\n\u003ctd\u003e\n5\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3109\" data-end=\"3208\"\u003e\n\u003ctd\u003e\nIKA\n\u003c\/td\u003e\n\u003ctd\u003e\nRW20DS25\n\u003c\/td\u003e\n\u003ctd\u003e\nMagnetic Stirrer\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3209\" data-end=\"3308\"\u003e\n\u003ctd\u003e\nBST\n\u003c\/td\u003e\n\u003ctd\u003e\nEKR1F\n\u003c\/td\u003e\n\u003ctd\u003e\nTemperature Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3309\" data-end=\"3408\"\u003e\n\u003ctd\u003e\nDURAG\n\u003c\/td\u003e\n\u003ctd\u003e\nDLE 603IS-P\n\u003c\/td\u003e\n\u003ctd\u003e\nEmission Monitor\n\u003c\/td\u003e\n\u003ctd\u003e\n5\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3409\" data-end=\"3508\"\u003e\n\u003ctd\u003e\nINFINEON\n\u003c\/td\u003e\n\u003ctd\u003e\nFZ800R16KF4\n\u003c\/td\u003e\n\u003ctd\u003e\nPower Module\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3509\" data-end=\"3608\"\u003e\n\u003ctd\u003e\nINFINEON\n\u003c\/td\u003e\n\u003ctd\u003e\nFZ1800R16KF4\n\u003c\/td\u003e\n\u003ctd\u003e\nPower Module\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3609\" data-end=\"3708\"\u003e\n\u003ctd\u003e\nKENETROL\n\u003c\/td\u003e\n\u003ctd\u003e\n144-040MP01V0C-0086\n\u003c\/td\u003e\n\u003ctd\u003e\nPressure Transducer\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3709\" data-end=\"3808\"\u003e\n\u003ctd\u003e\nDIGITAL\n\u003c\/td\u003e\n\u003ctd\u003e\nAR63C\n\u003c\/td\u003e\n\u003ctd\u003e\nFlow Sensor\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3809\" data-end=\"3907\"\u003e\n\u003ctd\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n690044-01\n\u003c\/td\u003e\n\u003ctd\u003e\nIndustrial Component\n\u003c\/td\u003e\n\u003ctd\u003e\n8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3908\" data-end=\"4007\"\u003e\n\u003ctd\u003e\nYUKEN\n\u003c\/td\u003e\n\u003ctd\u003e\nSK1119-A-D48-20\n\u003c\/td\u003e\n\u003ctd\u003e\nHydraulic Control Valve\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4008\" data-end=\"4107\"\u003e\n\u003ctd\u003e\nKROHNE\n\u003c\/td\u003e\n\u003ctd\u003e\nIFC300F\n\u003c\/td\u003e\n\u003ctd\u003e\nFlow Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4108\" data-end=\"4207\"\u003e\n\u003ctd\u003e\nKROHNE\n\u003c\/td\u003e\n\u003ctd\u003e\nIFC300W\n\u003c\/td\u003e\n\u003ctd\u003e\nFlow Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n5\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4208\" data-end=\"4307\"\u003e\n\u003ctd\u003e\nKROHNE\n\u003c\/td\u003e\n\u003ctd\u003e\nIFC300\n\u003c\/td\u003e\n\u003ctd\u003e\nFlow Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4308\" data-end=\"4407\"\u003e\n\u003ctd\u003e\nEWNE\n\u003c\/td\u003e\n\u003ctd\u003e\nA-1B1-1C1-A000\n\u003c\/td\u003e\n\u003ctd\u003e\nControl Module\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4408\" data-end=\"4506\"\u003e\n\u003ctd\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\nF9802EA-01\n\u003c\/td\u003e\n\u003ctd\u003e\nIndustrial Component\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4507\" data-end=\"4606\"\u003e\n\u003ctd\u003e\nFCI\n\u003c\/td\u003e\n\u003ctd\u003e\nL1B1C1\n\u003c\/td\u003e\n\u003ctd\u003e\nLevel Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4607\" data-end=\"4706\"\u003e\n\u003ctd\u003e\nZKTECO\n\u003c\/td\u003e\n\u003ctd\u003e\nTPM005\n\u003c\/td\u003e\n\u003ctd\u003e\nTime Attendance System\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4707\" data-end=\"4806\"\u003e\n\u003ctd\u003e\nCREATIVE\n\u003c\/td\u003e\n\u003ctd\u003e\nSBD490\n\u003c\/td\u003e\n\u003ctd\u003e\nSignal Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n10\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4807\" data-end=\"4906\"\u003e\n\u003ctd\u003e\nVESPA\n\u003c\/td\u003e\n\u003ctd\u003e\nET-4E1\n\u003c\/td\u003e\n\u003ctd\u003e\nFlow Control\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4907\" data-end=\"5006\"\u003e\n\u003ctd\u003e\nJUMO\n\u003c\/td\u003e\n\u003ctd\u003e\n701140\/8888-888-23-064\n\u003c\/td\u003e\n\u003ctd\u003e\nPressure Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n5\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5007\" data-end=\"5106\"\u003e\n\u003ctd\u003e\nJUMO\n\u003c\/td\u003e\n\u003ctd\u003e\n701160\/8-0153-001-23\n\u003c\/td\u003e\n\u003ctd\u003e\nPressure Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5107\" data-end=\"5206\"\u003e\n\u003ctd\u003e\nJUMO\n\u003c\/td\u003e\n\u003ctd\u003e\n701140\/8888-888-23\n\u003c\/td\u003e\n\u003ctd\u003e\nPressure Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5207\" data-end=\"5306\"\u003e\n\u003ctd\u003e\nREOTRON\n\u003c\/td\u003e\n\u003ctd\u003e\n567LH-DP24\n\u003c\/td\u003e\n\u003ctd\u003e\nDiscrete I\/O Module\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5307\" data-end=\"5406\"\u003e\n\u003ctd\u003e\nMTL\n\u003c\/td\u003e\n\u003ctd\u003e\n8502-BI-DP\n\u003c\/td\u003e\n\u003ctd\u003e\nSignal Isolator\n\u003c\/td\u003e\n\u003ctd\u003e\n8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5407\" data-end=\"5506\"\u003e\n\u003ctd\u003e\nDP\n\u003c\/td\u003e\n\u003ctd\u003e\nCPCPIAC-6U-500\n\u003c\/td\u003e\n\u003ctd\u003e\nPCI Adapter\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5507\" data-end=\"5606\"\u003e\n\u003ctd\u003e\nMTL\n\u003c\/td\u003e\n\u003ctd\u003e\nCP-DYNA-2AIO\n\u003c\/td\u003e\n\u003ctd\u003e\nAnalog I\/O Module\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5607\" data-end=\"5706\"\u003e\n\u003ctd\u003e\nHORNER APG\n\u003c\/td\u003e\n\u003ctd\u003e\nHE700GEN200\n\u003c\/td\u003e\n\u003ctd\u003e\nHMI Control Panel\n\u003c\/td\u003e\n\u003ctd\u003e\n8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5707\" data-end=\"5808\"\u003e\n\u003ctd\u003e\nGRAM\u0026amp;JUHL\n\u003c\/td\u003e\n\u003ctd\u003e\n5000-0014-0004 M-SYSTEM MKLL\n\u003c\/td\u003e\n\u003ctd\u003e\nControl System\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5809\" data-end=\"5908\"\u003e\n\u003ctd\u003e\nKEYANG\n\u003c\/td\u003e\n\u003ctd\u003e\nTCD-708\n\u003c\/td\u003e\n\u003ctd\u003e\nTimer Control Device\n\u003c\/td\u003e\n\u003ctd\u003e\n10\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5909\" data-end=\"6008\"\u003e\n\u003ctd\u003e\nATOS\n\u003c\/td\u003e\n\u003ctd\u003e\nRZMO-P1-04-A-010\/100 20\n\u003c\/td\u003e\n\u003ctd\u003e\nHydraulic Valve\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6009\" data-end=\"6108\"\u003e\n\u003ctd\u003e\nKK\n\u003c\/td\u003e\n\u003ctd\u003e\nV301-2-S\n\u003c\/td\u003e\n\u003ctd\u003e\nVoltage Regulator\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6109\" data-end=\"6209\"\u003e\n\u003ctd\u003e\nEUPEC\n\u003c\/td\u003e\n\u003ctd\u003e\nBSM200GA170DN2SE3256\n\u003c\/td\u003e\n\u003ctd\u003e\nPower Module\n\u003c\/td\u003e\n\u003ctd\u003e\n8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6210\" data-end=\"6309\"\u003e\n\u003ctd\u003e\nWeidmuller\n\u003c\/td\u003e\n\u003ctd\u003e\n9662-110\n\u003c\/td\u003e\n\u003ctd\u003e\nTerminal Block\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6310\" data-end=\"6409\"\u003e\n\u003ctd\u003e\nVGA\n\u003c\/td\u003e\n\u003ctd\u003e\n7000V-10-V12-05\n\u003c\/td\u003e\n\u003ctd\u003e\nVoltage Transducer\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6410\" data-end=\"6510\"\u003e\n\u003ctd\u003e\nGuntermann \u0026amp; Drunck\n\u003c\/td\u003e\n\u003ctd\u003e\nA1120003\n\u003c\/td\u003e\n\u003ctd\u003e\nKVM Switch\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6511\" data-end=\"6611\"\u003e\n\u003ctd\u003e\nGuntermann \u0026amp; Drunck\n\u003c\/td\u003e\n\u003ctd\u003e\nA1220001\n\u003c\/td\u003e\n\u003ctd\u003e\nKVM Switch\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6612\" data-end=\"6711\"\u003e\n\u003ctd\u003e\nDRAGER\n\u003c\/td\u003e\n\u003ctd\u003e\nARBK-0181\n\u003c\/td\u003e\n\u003ctd\u003e\nGas Detection\n\u003c\/td\u003e\n\u003ctd\u003e\n10\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6712\" data-end=\"6811\"\u003e\n\u003ctd\u003e\nDRAGER\n\u003c\/td\u003e\n\u003ctd\u003e\nARXE-0248\n\u003c\/td\u003e\n\u003ctd\u003e\nGas Detection\n\u003c\/td\u003e\n\u003ctd\u003e\n8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6812\" data-end=\"6911\"\u003e\n\u003ctd\u003e\nHT\n\u003c\/td\u003e\n\u003ctd\u003e\nHT201\n\u003c\/td\u003e\n\u003ctd\u003e\nHumidity Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6912\" data-end=\"7011\"\u003e\n\u003ctd\u003e\nLEONOVE\n\u003c\/td\u003e\n\u003ctd\u003e\nSPM\n\u003c\/td\u003e\n\u003ctd\u003e\nSignal Processing Module\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7012\" data-end=\"7111\"\u003e\n\u003ctd\u003e\nCOLLIHIGH\n\u003c\/td\u003e\n\u003ctd\u003e\nKLWSH-5ATDENY\n\u003c\/td\u003e\n\u003ctd\u003e\nElectrical Switch\n\u003c\/td\u003e\n\u003ctd\u003e\n5\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7112\" data-end=\"7211\"\u003e\n\u003ctd\u003e\n1+MEACTIA\n\u003c\/td\u003e\n\u003ctd\u003e\nIME4201201\n\u003c\/td\u003e\n\u003ctd\u003e\nControl Module\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7212\" data-end=\"7311\"\u003e\n\u003ctd\u003e\nQUEST\n\u003c\/td\u003e\n\u003ctd\u003e\nQ-300\n\u003c\/td\u003e\n\u003ctd\u003e\nSignal Transducer\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7312\" data-end=\"7411\"\u003e\n\u003ctd\u003e\nRAE\n\u003c\/td\u003e\n\u003ctd\u003e\nVRAE\n\u003c\/td\u003e\n\u003ctd\u003e\nGas Detection\n\u003c\/td\u003e\n\u003ctd\u003e\n8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7412\" data-end=\"7511\"\u003e\n\u003ctd\u003e\nSCHMERSAL\n\u003c\/td\u003e\n\u003ctd\u003e\nT3Z068-22YR\n\u003c\/td\u003e\n\u003ctd\u003e\nSafety Switch\n\u003c\/td\u003e\n\u003ctd\u003e\n10\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7512\" data-end=\"7611\"\u003e\n\u003ctd\u003e\nRHEONIK\n\u003c\/td\u003e\n\u003ctd\u003e\nRHE-04017\n\u003c\/td\u003e\n\u003ctd\u003e\nFlow Meter\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7612\" data-end=\"7711\"\u003e\n\u003ctd\u003e\nDORLIER\n\u003c\/td\u003e\n\u003ctd\u003e\nLET-OFF-MODULE 389157\n\u003c\/td\u003e\n\u003ctd\u003e\nControl Module\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7712\" data-end=\"7811\"\u003e\n\u003ctd\u003e\nDORLIER\n\u003c\/td\u003e\n\u003ctd\u003e\nWM-CONTROL-MODULE 389185\n\u003c\/td\u003e\n\u003ctd\u003e\nControl Module\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7812\" data-end=\"7911\"\u003e\n\u003ctd\u003e\nDORLIER\n\u003c\/td\u003e\n\u003ctd\u003e\nPATTERN-MODULE 389221\n\u003c\/td\u003e\n\u003ctd\u003e\nControl Module\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7912\" data-end=\"8011\"\u003e\n\u003ctd\u003e\nDORLIER\n\u003c\/td\u003e\n\u003ctd\u003e\nI\/O-MODULE 389179\n\u003c\/td\u003e\n\u003ctd\u003e\nInput\/Output Module\n\u003c\/td\u003e\n\u003ctd\u003e\n5\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"8012\" data-end=\"8111\"\u003e\n\u003ctd\u003e\nDORLIER\n\u003c\/td\u003e\n\u003ctd\u003e\nSTART-STOF-MODULE 129743\n\u003c\/td\u003e\n\u003ctd\u003e\nControl Module\n\u003c\/td\u003e\n\u003ctd\u003e\n8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"8112\" data-end=\"8211\"\u003e\n\u003ctd\u003e\nCREVIS\n\u003c\/td\u003e\n\u003ctd\u003e\nST-7641\n\u003c\/td\u003e\n\u003ctd\u003e\nSignal Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"8212\" data-end=\"8311\"\u003e\n\u003ctd\u003e\nWeidmuller\n\u003c\/td\u003e\n\u003ctd\u003e\n9662-110 7760050029\n\u003c\/td\u003e\n\u003ctd\u003e\nTerminal Block\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"8312\" data-end=\"8410\"\u003e\n\u003ctd\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\nFS3\/5\n\u003c\/td\u003e\n\u003ctd\u003e\nIndustrial Component\n\u003c\/td\u003e\n\u003ctd\u003e\n8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"8411\" data-end=\"8510\"\u003e\n\u003ctd\u003e\nAGLIENT\n\u003c\/td\u003e\n\u003ctd\u003e\nE1401B\n\u003c\/td\u003e\n\u003ctd\u003e\nOscilloscope\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"8511\" data-end=\"8610\"\u003e\n\u003ctd\u003e\nAGLIENT\n\u003c\/td\u003e\n\u003ctd\u003e\nE1411B\n\u003c\/td\u003e\n\u003ctd\u003e\nOscilloscope\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"8611\" data-end=\"8710\"\u003e\n\u003ctd\u003e\nAGLIENT\n\u003c\/td\u003e\n\u003ctd\u003e\nE1420B\n\u003c\/td\u003e\n\u003ctd\u003e\nOscilloscope\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"8711\" data-end=\"8810\"\u003e\n\u003ctd\u003e\nAGLIENT\n\u003c\/td\u003e\n\u003ctd\u003e\nE6173A\n\u003c\/td\u003e\n\u003ctd\u003e\nTest Instrument\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"8811\" data-end=\"8910\"\u003e\n\u003ctd\u003e\nAGLIENT\n\u003c\/td\u003e\n\u003ctd\u003e\nTRIGGER1-A\n\u003c\/td\u003e\n\u003ctd\u003e\nTrigger Module\n\u003c\/td\u003e\n\u003ctd\u003e\n5\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"8911\" data-end=\"9010\"\u003e\n\u003ctd\u003e\nAGLIENT\n\u003c\/td\u003e\n\u003ctd\u003e\nTRIGGER1-B\n\u003c\/td\u003e\n\u003ctd\u003e\nTrigger Module\n\u003c\/td\u003e\n\u003ctd\u003e\n10\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9011\" data-end=\"9110\"\u003e\n\u003ctd\u003e\nBOSCH\n\u003c\/td\u003e\n\u003ctd\u003e\nVXI-MXI-2\n\u003c\/td\u003e\n\u003ctd\u003e\nModular Interface\n\u003c\/td\u003e\n\u003ctd\u003e\n8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9111\" data-end=\"9210\"\u003e\n\u003ctd\u003e\nBOSCH\n\u003c\/td\u003e\n\u003ctd\u003e\nVXK5000\n\u003c\/td\u003e\n\u003ctd\u003e\nBus Controller\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9211\" data-end=\"9310\"\u003e\n\u003ctd\u003e\nBOSCH\n\u003c\/td\u003e\n\u003ctd\u003e\nVXK5010\n\u003c\/td\u003e\n\u003ctd\u003e\nBus Controller\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9311\" data-end=\"9410\"\u003e\n\u003ctd\u003e\nBOSCH\n\u003c\/td\u003e\n\u003ctd\u003e\nVXK5020\n\u003c\/td\u003e\n\u003ctd\u003e\nBus Controller\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9411\" data-end=\"9510\"\u003e\n\u003ctd\u003e\nHP\n\u003c\/td\u003e\n\u003ctd\u003e\nE1420B\n\u003c\/td\u003e\n\u003ctd\u003e\nTest Equipment\n\u003c\/td\u003e\n\u003ctd\u003e\n8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9511\" data-end=\"9610\"\u003e\n\u003ctd\u003e\nMTL\n\u003c\/td\u003e\n\u003ctd\u003e\nMTL4016\n\u003c\/td\u003e\n\u003ctd\u003e\nSignal Isolator\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9611\" data-end=\"9710\"\u003e\n\u003ctd\u003e\nGOODRICH\n\u003c\/td\u003e\n\u003ctd\u003e\n8ES4550 12-06\n\u003c\/td\u003e\n\u003ctd\u003e\nSensor\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9711\" data-end=\"9810\"\u003e\n\u003ctd\u003e\nBATTERY PACK\n\u003c\/td\u003e\n\u003ctd\u003e\nD717-01-100\n\u003c\/td\u003e\n\u003ctd\u003e\nBattery Pack\n\u003c\/td\u003e\n\u003ctd\u003e\n5\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9811\" data-end=\"9910\"\u003e\n\u003ctd\u003e\nBASLER\n\u003c\/td\u003e\n\u003ctd\u003e\nA404KC\n\u003c\/td\u003e\n\u003ctd\u003e\nSignal Processing\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9911\" data-end=\"10010\"\u003e\n\u003ctd\u003e\nTEWS\n\u003c\/td\u003e\n\u003ctd\u003e\nTVME200-10\n\u003c\/td\u003e\n\u003ctd\u003e\nBus Interface\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"10011\" data-end=\"10110\"\u003e\n\u003ctd\u003e\nFUJI\n\u003c\/td\u003e\n\u003ctd\u003e\nNP1L-AS2\n\u003c\/td\u003e\n\u003ctd\u003e\nPressure Transducer\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"10111\" data-end=\"10210\"\u003e\n\u003ctd\u003e\nFUJI\n\u003c\/td\u003e\n\u003ctd\u003e\nNP1AXH4-PT\n\u003c\/td\u003e\n\u003ctd\u003e\nPressure Transducer\n\u003c\/td\u003e\n\u003ctd\u003e\n5\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"10211\" data-end=\"10310\"\u003e\n\u003ctd\u003e\nPVTVM\n\u003c\/td\u003e\n\u003ctd\u003e\nTM0180-07-00-09-10-02\n\u003c\/td\u003e\n\u003ctd\u003e\nFlow Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"10311\" data-end=\"10410\"\u003e\n\u003ctd\u003e\nPVTVM\n\u003c\/td\u003e\n\u003ctd\u003e\nTM0181-075-00\n\u003c\/td\u003e\n\u003ctd\u003e\nFlow Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"10411\" data-end=\"10510\"\u003e\n\u003ctd\u003e\nPVTVM\n\u003c\/td\u003e\n\u003ctd\u003e\nTM0180-07-00-07-05-02\n\u003c\/td\u003e\n\u003ctd\u003e\nFlow Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"10511\" data-end=\"10610\"\u003e\n\u003ctd\u003e\nPVTVM\n\u003c\/td\u003e\n\u003ctd\u003e\nTM0180-05-05-03-10-02\n\u003c\/td\u003e\n\u003ctd\u003e\nFlow Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n5\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"10611\" data-end=\"10710\"\u003e\n\u003ctd\u003e\nPVTVM\n\u003c\/td\u003e\n\u003ctd\u003e\nTM0180-07-00-06-05-02\n\u003c\/td\u003e\n\u003ctd\u003e\nFlow Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"10711\" data-end=\"10810\"\u003e\n\u003ctd\u003e\nPVTVM\n\u003c\/td\u003e\n\u003ctd\u003e\nTM0180-07-00-05-10-02\n\u003c\/td\u003e\n\u003ctd\u003e\nFlow Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"10811\" data-end=\"10910\"\u003e\n\u003ctd\u003e\nPVTVM\n\u003c\/td\u003e\n\u003ctd\u003e\nTM0180-05-05-03-15-02\n\u003c\/td\u003e\n\u003ctd\u003e\nFlow Transmitter\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"10911\" data-end=\"11014\"\u003e\n\u003ctd\u003e\nPREDICTECH\n\u003c\/td\u003e\n\u003ctd\u003e\nTM301-A00-B00-C00-D00-E00-F00-G00\n\u003c\/td\u003e\n\u003ctd\u003e\nControl System\n\u003c\/td\u003e\n\u003ctd\u003e\n10\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"11015\" data-end=\"11118\"\u003e\n\u003ctd\u003e\nPREDICTECH\n\u003c\/td\u003e\n\u003ctd\u003e\nTM301-A02-B00-C00-D00-E00-F00-G00\n\u003c\/td\u003e\n\u003ctd\u003e\nControl System\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"11119\" data-end=\"11222\"\u003e\n\u003ctd\u003e\nPREDICTECH\n\u003c\/td\u003e\n\u003ctd\u003e\nTM302-A00-B00-C00-D00-E00-F00-G00\n\u003c\/td\u003e\n\u003ctd\u003e\nControl System\n\u003c\/td\u003e\n\u003ctd\u003e\n8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"11223\" data-end=\"11324\"\u003e\n\u003ctd\u003e\nPREDICTECH\n\u003c\/td\u003e\n\u003ctd\u003e\nTM201-A02-B00-C00-D00-E00-G00\n\u003c\/td\u003e\n\u003ctd\u003e\nControl System\n\u003c\/td\u003e\n\u003ctd\u003e\n7\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"11325\" data-end=\"11426\"\u003e\n\u003ctd\u003e\nPREDICTECH\n\u003c\/td\u003e\n\u003ctd\u003e\nTM201-A00-B00-C00-D00-E00-G00\n\u003c\/td\u003e\n\u003ctd\u003e\nControl System\n\u003c\/td\u003e\n\u003ctd\u003e\n6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"11427\" data-end=\"11526\"\u003e\n\u003ctd\u003e\nERNI\n\u003c\/td\u003e\n\u003ctd\u003e\nREL054\n\u003c\/td\u003e\n\u003ctd\u003e\nConnector\n\u003c\/td\u003e\n\u003ctd\u003e\n9\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"11527\" data-end=\"11626\"\u003e\n\u003ctd\u003e\nMTL\n\u003c\/td\u003e\n\u003ctd\u003e\nMTL5581\n\u003c\/td\u003e\n\u003ctd\u003e\nSignal Isolator\n\u003c\/td\u003e\n\u003ctd\u003e\n5\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52755194872093,"sku":"ZR402G-T-E-E-A\/HS\/SCT","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/Yokogawa-ZR402G-T-E-E-A-HS-SCT_1000.jpg?v=1787193827","url":"https:\/\/www.6gcontrols.com\/products\/yokogawa-zr402g-t-e-e-a-hs-sct-separate-type-zirconia-oxygen-analyzer","provider":"6G Controls","version":"1.0","type":"link"}