{"product_id":"ics-triplex-t8310-trusted-tmr-expander-processor-module","title":"Módulo processador expansor TMR Trusted ICS Triplex T8310","description":"\u003ch2\u003eICS Triplex T8310 Trusted TMR Expander Processor Module\u003c\/h2\u003e\r\nConfigured for fault-tolerant I\/O expansion in Trusted safety platforms, the \u003cstrong\u003eICS Triplex T8310\u003c\/strong\u003e (\u003cstrong\u003eT8310\u003c\/strong\u003e TMR Expander Processor Module) provides direct physical\/electrical execution.\r\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\r\n\u003cfigure class=\"table\"\u003e\r\n\u003ctable\u003e\r\n\u003cthead\u003e\r\n\u003ctr\u003e\r\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\r\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/thead\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eModel\u003c\/td\u003e\r\n\u003ctd\u003eT8310\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBrand\u003c\/td\u003e\r\n\u003ctd\u003eICS Triplex\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eWeight\u003c\/td\u003e\r\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDimensions\u003c\/td\u003e\r\n\u003ctd\u003e160 x 320 x 120 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\r\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\r\n\u003ctd\u003e40-80 W\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eArchitecture\u003c\/td\u003e\r\n\u003ctd\u003eTriple Modular Redundancy (TMR) 2oo3\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\r\n\u003ctd\u003e20-32 VDC\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSafety Certification\u003c\/td\u003e\r\n\u003ctd\u003eSIL3\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eHot Link Interface\u003c\/td\u003e\r\n\u003ctd\u003eTC-301 port (250 Mbps)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\r\n\u003ctd\u003e1500-2500 VDC channel-to-channel and channel-to-chassis\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\r\n\u003ctd\u003eIP20\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003c\/figure\u003e\r\n\u003ch3\u003eHigh-Reliability Safety Control \u0026amp; TMR Architecture\u003c\/h3\u003e\r\nThe module utilizes a Triple Modular Redundancy (TMR) 2oo3 architecture to execute continuous fail-safe state processing without interruption. Internal hardware-implemented Fault Tolerant (HIFT) voting algorithms evaluate three independent processing channels before issuing backplane control commands. Galvanic isolation up to 2500 VDC across internal buses isolates field perturbations from core execution circuits. In the event of a channel failure, the module initiates a transparent hot-standby failover sequence, keeping output loops active while logging diagnostic events to the system backplane.\r\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\r\nQ: Can the module be inserted into the expander chassis while the system is powered?\r\n\r\nA: Yes. The module supports live insertion and removal (hot-swapping) inside the T8300 expander chassis without interrupting execution on adjacent active slots or triggering system trip conditions.\r\n\r\nQ: What power bus parameters are required to ensure uninterrupted execution?\r\n\r\nA: The backplane supply must maintain dual-redundant voltage levels between 20 VDC and 32 VDC. Transient voltage drops below 20 VDC will trigger internal power diagnostics and may force a safe channel shutdown.\r\n\r\nQ: How is galvanic isolation verified across the communication interfaces?\r\n\r\nA: The onboard physical interfaces, including TC-301 hot link and dual Ethernet ports, feature rated channel-to-chassis isolation from 1500 VDC to 2500 VDC to prevent ground loops between the main processor chassis and expander chassis.\r\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\r\nEnsure the T8300 expander chassis backplane is clean and free of conductive debris before insertion. Align the module card edges with the designated dual-slot guide rails and push firmly until the rear backplane connectors fully seat. Secure the retaining screws on the front panel to a torque specification of 0.6 Nm to maintain earth grounding continuity and vibration immunity.\r\n\r\nAll TC-301 expander hot-link cables must maintain minimum bending radiuses compliant with industrial Ethernet routing standards. Diagnostic RS-232 and communication shield drain wires must terminate directly to the chassis ground bar using low-impedance clamps. Ensure ambient airflow across the IP20 front panel vents remains unobstructed to maintain operating temperatures within the specified -40 to +70 deg C range.","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":52750335901981,"sku":"T8310","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/T8310-2_1000.jpg?v=1787033323","url":"https:\/\/www.6gcontrols.com\/pt\/products\/ics-triplex-t8310-trusted-tmr-expander-processor-module","provider":"6G Controls","version":"1.0","type":"link"}