{"product_id":"schneider-electric-bmxnom0200h-modicon-x80-serial-communication-module","title":"Schneider Electric BMXNOM0200H Modicon X80 Serial Communication Module","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMXNOM0200H\u003c\/strong\u003e is a rugged serial communication module in the Modicon X80 range, designed to provide two independent RS-232\/RS-485 interfaces for Modbus RTU and ASCII communication. It supports serial connections to external devices through RJ45 ports and features a protective coating for operation in demanding industrial environments. Its extended operating temperature range and compatibility with Modicon M340 and M580 PLC platforms support its use in different automation architectures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSerial Communication Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXNOM0200H provides two serial communication ports with different electrical interfaces and transmission rates:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS-232:\u003c\/strong\u003e RJ45 connection, 115.2 kbit\/s, 8-wire interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS-485:\u003c\/strong\u003e RJ45 connection, 57.6 kbit\/s, one twisted two-wire pair.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese interfaces allow the PLC system to exchange data with external equipment using supported serial communication protocols. Modbus RTU uses binary data frames, while ASCII mode uses character-based message representation. The two interfaces provide separate connection points for serial communication devices.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply and Status Indication\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module receives its operating power internally through the module rack, rather than requiring a separate external power supply. Its current consumption is 80 mA at 24 V DC.\u003c\/p\u003e\n\u003cp\u003eFour LEDs provide local diagnostic information:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eERR: Red LED indicating a module fault.\u003c\/li\u003e\n\u003cli\u003eRUN: Green LED indicating normal module operation.\u003c\/li\u003e\n\u003cli\u003eSER COM 0: Green LED indicating activity on serial port 0.\u003c\/li\u003e\n\u003cli\u003eSER COM 1: Green LED indicating activity on serial port 1.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese indicators help maintenance personnel distinguish module operating status from serial communication activity during troubleshooting.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRugged Design and Environmental Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXNOM0200H features a protective coating intended for installations exposed to chemically aggressive environments. Its environmental specifications include resistance classifications for gases, dust, sand, salt, mould and fungal spores.\u003c\/p\u003e\n\u003cp\u003eThe module supports an operating temperature range of -25 to 70 deg C and relative humidity of 10-95%, provided that condensation does not occur. Its IP20 enclosure rating is intended for installation inside a suitable protected electrical cabinet.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePLC Platform Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXNOM0200H belongs to the Modicon X80 common module platform and is specified for use with Modicon M340 and M580 PLC systems. The shared X80 hardware environment allows the serial communication module to be incorporated into these supported automation architectures.\u003c\/p\u003e\n\u003cp\u003eThe module is a standard-format X80 module. Its compatibility should be checked against the selected PLC configuration and rack arrangement before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXNOM0200H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSerial Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eRugged industrial environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003e2 serial ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort 0 Interface\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort 0 Connector\u003c\/td\u003e\n\u003ctd\u003eRJ45, 8-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort 0 Transmission Rate\u003c\/td\u003e\n\u003ctd\u003e115.2 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort 1 Interface\u003c\/td\u003e\n\u003ctd\u003eRS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort 1 Connector\u003c\/td\u003e\n\u003ctd\u003eRJ45, twisted two-wire pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort 1 Transmission Rate\u003c\/td\u003e\n\u003ctd\u003e57.6 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus RTU, ASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eInternal, through module rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e80 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Coating\u003c\/td\u003e\n\u003ctd\u003eProtective lacquer coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Diagnostics\u003c\/td\u003e\n\u003ctd\u003eERR, RUN, SER COM 0, SER COM 1 LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible PLC Platforms\u003c\/td\u003e\n\u003ctd\u003eModicon M340, Modicon M580\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10-95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Resistance\u003c\/td\u003e\n\u003ctd\u003eClass Gx, ISA S71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Resistance\u003c\/td\u003e\n\u003ctd\u003eClass 3C4, IEC 60721-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDust Resistance\u003c\/td\u003e\n\u003ctd\u003eClass 3S4, IEC 60721-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSand Resistance\u003c\/td\u003e\n\u003ctd\u003eClass 3S4, IEC 60721-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalt Resistance\u003c\/td\u003e\n\u003ctd\u003eLevel 2, IEC 68252\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMould Resistance\u003c\/td\u003e\n\u003ctd\u003eClass 3B2, IEC 60721-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFungal Spore Resistance\u003c\/td\u003e\n\u003ctd\u003eClass 3B2, IEC 60721-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Classification\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, RCM, EAC, Marine, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2, IEC 61010-2-201, UL 61010-2-201, CSA C22.2 No. 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Environmental Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-6-5, IEC 61850-3, IEC 60079-0, IACS E10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEU Directives\u003c\/td\u003e\n\u003ctd\u003e2014\/35\/EU, 2014\/30\/EU, 2014\/34\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Against Electromagnetic Disturbances\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e3595864027388\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Carbon Footprint\u003c\/td\u003e\n\u003ctd\u003e102 kg CO2 eq.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the two serial ports on the BMXNOM0200H?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Port 0 uses RS-232 with an RJ45 connector and supports transmission rates up to 115.2 kbit\/s. Port 1 uses RS-485 with an RJ45 connector and a twisted two-wire connection, supporting up to 57.6 kbit\/s. These interfaces provide different electrical connection methods for serial communication equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which PLC systems support the BMXNOM0200H?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module is specified for Modicon M340 and Modicon M580 PLC platforms. It belongs to the shared Modicon X80 hardware range. The rack configuration and applicable hardware requirements should be checked before selecting the module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the BMXNOM0200H require a separate 24 V DC power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No separate external supply is specified for the module itself. It receives power internally through the module rack and has a stated current consumption of 80 mA at 24 V DC.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68137375465757,"sku":"BMXNOM0200H","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXNOM0200H.jpg?v=1795167655","url":"https:\/\/www.6gcontrols.com\/pt\/products\/schneider-electric-bmxnom0200h-modicon-x80-serial-communication-module","provider":"6G Controls","version":"1.0","type":"link"}