{"product_id":"schneider-electric-bmxcra31200-modicon-x80-ethernet-rio-head-adapter","title":"Schneider Electric BMXCRA31200 Modicon X80 Ethernet RIO Head Adapter","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMXCRA31200\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eBMXCRA31200\u003c\/strong\u003e Ethernet Remote I\/O (RIO) Head Adapter, provides EtherNet\/IP communication between a Modicon M580 or compatible automation controller and distributed Modicon X80 I\/O modules. It collects input data from remote modules and distributes output data received from the controller through a two-port Ethernet RIO network.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXCRA31200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEthernet Remote I\/O Head Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.225 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e32 x 100 x 87.5 mm (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1200 mA current consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Type\u003c\/td\u003e\n\u003ctd\u003eX-Bus via remote module rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Type\u003c\/td\u003e\n\u003ctd\u003eIPv4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Speed\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e10\/100BASE-TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Redundancy\u003c\/td\u003e\n\u003ctd\u003eRSTP ring topology support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Modes\u003c\/td\u003e\n\u003ctd\u003eHalf-duplex, Full-duplex, Auto-Negotiation, Auto-MDIX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Controllers\u003c\/td\u003e\n\u003ctd\u003eModicon M580, Modicon Quantum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e0 to 128 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e0 to 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Services\u003c\/td\u003e\n\u003ctd\u003eModbus TCP Server, SNMP Agent, SNTP Client, DHCP Client, TFTP Client, FTP Client, FDR Client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Services\u003c\/td\u003e\n\u003ctd\u003eQoS, CIP Explicit Messaging, Syslog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Function\u003c\/td\u003e\n\u003ctd\u003eCCOTF (Configuration Change on the Fly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvent Timestamping\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eRack-mounted, secured with two screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Transport Altitude\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, RCM, EAC, Merchant Navy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2, IEC 61010-2-201, IEC 61850-3, IEC 61000-6-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e3595864132457\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP Communication and Remote I\/O Architecture\u003c\/h3\u003e\n\u003cp\u003eThe BMXCRA31200 operates as the communication head of a Modicon X80 Ethernet Remote I\/O drop. Its two RJ45 interfaces connect the remote rack to the Ethernet RIO network using EtherNet\/IP.\u003c\/p\u003e\n\u003cp\u003eThe data exchange follows two directions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput processing:\u003c\/strong\u003e Remote digital and analog input modules acquire field signals and transfer the collected data through the X-Bus to the head adapter. The adapter communicates this information to the controller over the Ethernet RIO network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput processing:\u003c\/strong\u003e The adapter receives output data from the controller and distributes it to the corresponding remote output modules through the X-Bus.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRSTP support enables ring network topology. The adapter also provides network diagnostics, device diagnostics through Device DDT, and a 10 ms timestamping function for event data.\u003c\/p\u003e\n\u003cp\u003eCCOTF allows supported configuration changes without stopping the PLC. Actual availability depends on the controller architecture, configuration and supported module functions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the BMXCRA31200 support hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The supplied documentation specifies rack installation and fastening with two screws but does not establish hot-swap capability. Replacement procedures should follow the Modicon X80 hardware and system maintenance instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the current consumption and backplane voltage of this adapter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified current consumption is 1200 mA, with an input voltage of 3.3 VDC. The rack power budget should account for this load together with the installed I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the BMXCRA31200 operate in an Ethernet ring network?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. It supports RSTP ring topology through its two Ethernet ports. Network configuration and recovery behavior must be coordinated with the connected Ethernet RIO devices and controller architecture.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Installation:\u003c\/strong\u003e Install the BMXCRA31200 in the designated Modicon X80 module rack and secure it using the specified two mounting screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Verification:\u003c\/strong\u003e Check the rack power supply and verify that the specified 3.3 VDC input and 1200 mA current requirement are accommodated by the system power budget.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Connections:\u003c\/strong\u003e Connect the two RJ45 interfaces to the designated Ethernet RIO network ports. Verify cable integrity, connector engagement and network topology before commissioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Configuration:\u003c\/strong\u003e Configure the adapter within the controller's Ethernet RIO architecture. Check IP addressing, EtherNet\/IP communication and RSTP settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e Follow Schneider Electric grounding instructions for the X80 rack and Ethernet installation. Maintain appropriate separation between communication cables and high-voltage or motor power wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Diagnostics:\u003c\/strong\u003e Inspect the RUN, ERR, Mod Status, Net Status and STS indicators. Confirm normal module operation and Ethernet communication before enabling field output operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Conditions:\u003c\/strong\u003e Maintain an operating temperature between 0 and 60 deg C. The enclosure must provide protection appropriate to the module's IP20 rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration Validation:\u003c\/strong\u003e Verify I\/O channel allocation, Device DDT diagnostics and controller communication after installation. Test input acquisition and output updates before returning the remote station to service.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68096456786205,"sku":"BMXCRA31200","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXCRA312002.jpg?v=1794824304","url":"https:\/\/www.6gcontrols.com\/ro\/products\/schneider-electric-bmxcra31200-modicon-x80-ethernet-rio-head-adapter","provider":"6G Controls","version":"1.0","type":"link"}