{"product_id":"schneider-bmxcps4002h-modicon-x80-redundant-power-supply-module","title":"Schneider BMXCPS4002H Modicon X80 Redundant Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider BMXCPS4002H\u003c\/strong\u003e is a ruggedized power supply module in the Modicon X80 range, designed for redundant power architectures in industrial control systems. It accepts a 100-240 V AC primary supply and provides separate 3.3 V DC and 24 V DC outputs for I\/O module logic and module or processor power. Its extended operating temperature range of -25 to 70 deg C supports installations exposed to demanding environmental conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply Architecture and Output Capacity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXCPS4002H provides two secondary power outputs for the Modicon X80 backplane:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3.3 V DC:\u003c\/strong\u003e 5.5 A, with an output power of 18 W for I\/O module logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 V DC:\u003c\/strong\u003e 1.67 A, with an output power of 40 W for I\/O module power and processor supply, with the 3.3 V output unloaded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese outputs serve different power requirements within the control rack. The available output capacity must be considered when calculating the total power demand of installed modules, particularly when the 24 V DC output and processor supply are used together.\u003c\/p\u003e\n\u003cp\u003eThe module supports redundant power architectures and includes redundancy monitoring. Its diagnostic functions include remaining operating life information, temperature monitoring, redundancy testing and operating-time information, with extended diagnostics available over the network.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Protection and Electrical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe primary input accepts a nominal voltage range of 100-240 V AC, with an allowable input range of 85-264 V AC. It operates at 50\/60 Hz, with an acceptable frequency range of 47-63 Hz.\u003c\/p\u003e\n\u003cp\u003eThe secondary circuits include overload, overvoltage and short-circuit protection. The primary circuit also has internal protection that is not accessible to the user. These protection functions address different fault conditions on the input and output sides of the power supply.\u003c\/p\u003e\n\u003cp\u003eThe module has a maximum power dissipation of 8.5 W. Its inrush current reaches 30 A at 120 V and 60 A at 240 V, which should be considered when evaluating upstream circuit protection and power distribution.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConnections, Indicators and Reset\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXCPS4002H uses separate removable terminal blocks for power input and alarm relay connections:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOne 5-pin connector for AC power supply and protective earth.\u003c\/li\u003e\n\u003cli\u003eOne 2-pin connector for the alarm relay.\u003c\/li\u003e\n\u003cli\u003eTwo removable cage-type terminal blocks, with 5-way and 2-way configurations, included with the module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThree green LEDs indicate voltage availability, redundancy status and power supply status. A RESET button provides a cold-start function.\u003c\/p\u003e\n\u003cp\u003eThe primary-to-ground and primary-to-secondary insulation resistance is at least 100 MOhm. The specified interruption immunity is 1 ms, and the insulation withstand voltage varies according to the relevant circuit pair.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Environmental Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe power supply is designed for installation in a Modicon X80 module rack and is secured with two screws. Its IP20 protection rating applies to the specified enclosure protection level and does not indicate suitability for direct exposure to water or dust.\u003c\/p\u003e\n\u003cp\u003eThe ruggedized construction includes a protective coating and environmental resistance characteristics:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -25 to 70 deg C.\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 85 deg C.\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5-95% at 55 deg C, without condensation.\u003c\/li\u003e\n\u003cli\u003eOperating altitude: 0-2,000 m; derating applies from 2,000 to 5,000 m.\u003c\/li\u003e\n\u003cli\u003eVibration resistance: 3 Gn.\u003c\/li\u003e\n\u003cli\u003eShock resistance: 30 Gn.\u003c\/li\u003e\n\u003cli\u003eGas resistance: Class Gx according to ISA S71.04 and Class 3C4 according to IEC 60721-3-3.\u003c\/li\u003e\n\u003cli\u003eDust and sand resistance: Class 3S4 according to IEC 60721-3-3.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe specified environmental characteristics make this version suitable for installations requiring a wider operating temperature range and additional environmental resistance compared with standard indoor power supply configurations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXCPS4002H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModicon X80 Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eRuggedized power supply for redundant architectures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Compatibility\u003c\/td\u003e\n\u003ctd\u003eAll module racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Input Voltage\u003c\/td\u003e\n\u003ctd\u003e85-264 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Limits\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApparent Power\u003c\/td\u003e\n\u003ctd\u003e0.13 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e0.55 A at 240 V; 1.01 A at 115 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e30 A at 120 V; 60 A at 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3.3 V DC Output\u003c\/td\u003e\n\u003ctd\u003e5.5 A, 18 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 V DC Output\u003c\/td\u003e\n\u003ctd\u003e1.67 A, 40 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e8.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eSecondary overload, overvoltage and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eRedundant power architecture support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eNetwork diagnostics, temperature monitoring and redundancy testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e3 green LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset\u003c\/td\u003e\n\u003ctd\u003eCold-start RESET button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connections\u003c\/td\u003e\n\u003ctd\u003e1 x 5-pin power connector; 1 x 2-pin alarm relay connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003eAt least 100 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1,500 V primary\/secondary; 1,500 V primary\/earth; 2,300 V sensor supply circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e792,000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterruption Immunity\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eModicon X80 module rack, secured with 2 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% at 55 deg C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e3 Gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e30 Gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Coating\u003c\/td\u003e\n\u003ctd\u003eConformal protective coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0-2,000 m; derating from 2,000 to 5,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Classification\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications Listed\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, RCM, EAC, Merchant Navy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2, IEC 61010-2-201, UL 61010-2-201, CSA C22.2 No. 61010-2-201, IACS E10, EN\/IEC 61000-6-5, EN\/IEC 61850-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.51 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e3606480927577\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Carbon Footprint\u003c\/td\u003e\n\u003ctd\u003e495 kg CO2 eq.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between BMXCPS4002H and a standard Modicon X80 power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The BMXCPS4002H is the ruggedized version intended for demanding environmental conditions and redundant power architectures. Its specified operating temperature range is -25 to 70 deg C, and it includes environmental resistance characteristics for industrial installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the BMXCPS4002H supply both the I\/O logic and processor power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. It provides separate 3.3 V DC and 24 V DC outputs. The 3.3 V output supplies I\/O module logic, while the 24 V output supplies I\/O modules and the processor. The specified 40 W capacity at 24 V DC assumes the 3.3 V output is unloaded.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What connections are provided for the power supply and alarm relay?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module has a 5-pin connector for the AC supply and protective earth, together with a 2-pin connector for the alarm relay. Both removable cage-type terminal blocks are included with the power supply.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68096090997021,"sku":"BMXCPS4002H","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXCPS4002H2.jpg?v=1794823255","url":"https:\/\/www.6gcontrols.com\/ru\/products\/schneider-bmxcps4002h-modicon-x80-redundant-power-supply-module","provider":"6G Controls","version":"1.0","type":"link"}