{"product_id":"schneider-electric-bmxamo0802h-modicon-x80-analog-output-module","title":"Schneider Electric BMXAMO0802H Modicon X80 Analog Output Module","description":"\u003cp\u003eConfigured for analog current signal generation in Modicon X80 I\/O architectures, the \u003cstrong\u003eSchneider Electric BMXAMO0802H\u003c\/strong\u003e (\u003cstrong\u003eBMXAMO0802H\u003c\/strong\u003e analog output module) provides 8 non-isolated 0-20 mA or 4-20 mA output channels through the rack power and backplane interface. The module provides 16-bit resolution, conversion time of \u0026lt;= 4 ms, and configurable fallback behavior.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXAMO0802H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog output module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eNon-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 350 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Error\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 0.45% of full scale from -25 to 70 deg C; 0.1% of full scale at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e45 ppm\/deg C for 0-20 mA and 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Crosstalk Attenuation\u003c\/td\u003e\n\u003ctd\u003e80 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e80 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1400 VDC between channels and ground; 1400 VDC between channels and bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003eInternal power supply via rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3.6 W at 24 VDC typical; 3.9 W at 24 VDC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e150 mA at 3.3 VDC; 135 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% at 55 deg C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e3 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e30 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e32 x 100 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eModicon X80 rack, fixed with 2 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e20-way connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indication\u003c\/td\u003e\n\u003ctd\u003eRUN, channel diagnostic, ERR, I\/O LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, RCM, EAC, UKCA, Merchant Navy, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2, IEC 61000-6-4, IEC 61000-6-2, EN 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Controllers\u003c\/td\u003e\n\u003ctd\u003eModicon M340 and Modicon M580 local or remote I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModicon X80 Backplane and Analog Signal Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe BMXAMO0802H receives its internal supply through the Modicon X80 rack and exchanges I\/O data through the rack backplane. The eight output channels generate either 0-20 mA or 4-20 mA current signals with 16-bit resolution. Each channel is non-isolated from the other output channels at the signal interface.\u003c\/p\u003e\n\u003cp\u003eThe specified load impedance is \u0026lt;= 350 Ohm for both current ranges. The module provides a minimum 80 dB crosstalk attenuation and 80 dB common mode rejection. Open-circuit detection applies to the 4-20 mA range, while short-circuit detection applies to the 0-20 mA range. Output conversion time is \u0026lt;= 4 ms.\u003c\/p\u003e\n\u003cp\u003eThe H suffix identifies the ruggedized version with conformal coating and an extended operating range of -25 to 70 deg C. The module is intended for installation in compatible Modicon X80 racks used with Modicon M340 and M580 controllers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the BMXAMO0802H output channel interface isolated?\u003c\/p\u003e\n\u003cp\u003eA: No. The eight analog output channels are specified as non-isolated. The module nevertheless specifies 1400 VDC isolation between channels and ground and between channels and the bus.\u003c\/p\u003e\n\u003cp\u003eQ: What current ranges can the BMXAMO0802H generate?\u003c\/p\u003e\n\u003cp\u003eA: Each analog output supports 0-20 mA and 4-20 mA current operation. The maximum conversion value is specified as 0-21 mA for both configured ranges.\u003c\/p\u003e\n\u003cp\u003eQ: How is the module powered in an X80 system?\u003c\/p\u003e\n\u003cp\u003eA: The module receives its internal power through the Modicon X80 rack. Specified consumption is 3.6 W typical and 3.9 W maximum at 24 VDC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the BMXAMO0802H on the designated Modicon X80 rack position and secure the module with the specified two mounting screws. Verify that the rack and removable 20-way terminal connection are correctly seated before energizing the system.\u003c\/p\u003e\n\u003cp\u003eRoute analog current wiring separately from high-voltage power conductors and high-current switching circuits where practical. Use appropriate shielded instrumentation cable when required by the installation environment. Terminate cable shields according to the plant grounding scheme and avoid creating unintended ground loops.\u003c\/p\u003e\n\u003cp\u003eVerify that each connected load remains within the specified \u0026lt;= 350 Ohm impedance. For 4-20 mA circuits, check loop continuity before enabling the output. Confirm channel configuration, fallback behavior, and output range in the controller configuration before placing the channel into service.\u003c\/p\u003e\n\u003cp\u003eThe BMXAMO0802H is IP20 and is intended for installation inside a suitable enclosure. The conformal-coated H version supports the specified -25 to 70 deg C operating range and environmental resistance characteristics stated by the manufacturer.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52998574637341,"sku":"BMXAMO0802H","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXAMO0802H2.jpg?v=1789963141","url":"https:\/\/www.6gcontrols.com\/ru\/products\/schneider-electric-bmxamo0802h-modicon-x80-analog-output-module","provider":"6G Controls","version":"1.0","type":"link"}