{"product_id":"schneider-electric-bmxamm0600-modicon-x80-mixed-analog-i-o-module","title":"Schneider Electric BMXAMM0600 Modicon X80 Mixed Analog I\/O Module","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMXAMM0600\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eBMXAMM0600\u003c\/strong\u003e Mixed Analog I\/O Module, provides four non-isolated analog inputs and two non-isolated analog outputs for voltage and current signal acquisition and generation within the Modicon X80 platform. It occupies one rack slot and uses a 20-way connector.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXAMM0600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMixed Analog I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signals\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA, 0-5 V, 1-5 V, 0-10 V, +\/-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signals\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA, +\/-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resolution\u003c\/td\u003e\n\u003ctd\u003e12 bits to 14 bits, depending on range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resolution\u003c\/td\u003e\n\u003ctd\u003e11 bits for current ranges; 12 bits for +\/-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Isolation\u003c\/td\u003e\n\u003ctd\u003eNon-isolated between channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrosstalk Attenuation\u003c\/td\u003e\n\u003ctd\u003eMinimum 70 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e80 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1400 V DC channel-to-ground; 1400 V DC channel-to-bus; 750 V DC between I\/O groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFast Read Cycle\u003c\/td\u003e\n\u003ctd\u003e1 ms + 1 ms x number of channels used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Read Cycle\u003c\/td\u003e\n\u003ctd\u003e5 ms for 4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Conversion Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003e20-way, 1 connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.6 W typical, 3.2 W maximum at 24 V DC; 0.35 W typical, 0.48 W maximum at 3.3 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e240 mA at 3.3 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% at 55 deg C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e3 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e30 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.155 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.5 cm x 11.0 cm x 11.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, RCM, CSA, EAC, Merchant Navy, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-2-201, IEC 61131-2, UL 61010-2-201, CSA C22.2 No 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware\u003c\/td\u003e\n\u003ctd\u003eSV01.50 listed in supplied product data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eAnalog Signal Integrity and I\/O Conversion\u003c\/h3\u003e\n\u003cp\u003eThe BMXAMM0600 uses separate configurable voltage and current ranges for its four analog inputs and two analog outputs. Input conversion supports 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, 0-10 V, and +\/-10 V. Output conversion supports 0-20 mA, 4-20 mA, and +\/-10 V.\u003c\/p\u003e\n\u003cp\u003eThe input channels use firmware-based first-order digital filtering. The specified minimum crosstalk attenuation is 70 dB, with 80 dB common mode rejection. Input measurement error varies with signal range and temperature, with supplied specifications ranging from 0.25% to 0.5% of full scale for current inputs and up to 0.35% of full scale for voltage inputs under the stated conditions.\u003c\/p\u003e\n\u003cp\u003eThe module provides fallback operation through predefined or configurable behavior. Status indication includes RUN, channel diagnostic, ERR, and I\/O LEDs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Are the four analog input channels galvanically isolated from each other?\u003cbr\u003eA: No. The analog inputs are specified as non-isolated between channels. The module nevertheless specifies 1400 V DC isolation between channels and ground and between channels and the bus, plus 750 V DC between groups of I\/O channels.\u003c\/p\u003e\n\u003cp\u003eQ: What signal ranges can the analog inputs accept?\u003cbr\u003eA: Each input can be configured for 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, 0-10 V, or +\/-10 V operation.\u003c\/p\u003e\n\u003cp\u003eQ: What is the specified power consumption?\u003cbr\u003eA: Consumption is 2.6 W typical and 3.2 W maximum at 24 V DC, with an additional 0.35 W typical and 0.48 W maximum at 3.3 V DC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in a compatible Modicon X80 rack and secure the module according to the rack installation procedure.\u003c\/li\u003e\n\u003cli\u003eUse the specified 20-way connector and verify terminal assignments before applying field signals.\u003c\/li\u003e\n\u003cli\u003eKeep analog signal wiring separated from high-current switching, motor, and power wiring where practical.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the plant grounding scheme and the applicable Modicon X80 installation requirements.\u003c\/li\u003e\n\u003cli\u003eVerify the configured input or output range against the connected field instrument before energizing the channel.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the specified input overload limits or output maximum conversion values.\u003c\/li\u003e\n\u003cli\u003eCheck RUN, ERR, I\/O, and channel diagnostic LEDs after startup.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified 0 to 60 deg C operating environment and IP20 enclosure conditions.\u003c\/li\u003e\n\u003cli\u003eVerify signal polarity and current-loop wiring before commissioning voltage or current channels.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52998566052125,"sku":"BMXAMM0600","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXAMM06002.jpg?v=1789962468","url":"https:\/\/www.6gcontrols.com\/sr\/products\/schneider-electric-bmxamm0600-modicon-x80-mixed-analog-i-o-module","provider":"6G Controls","version":"1.0","type":"link"}