{"product_id":"schneider-bmxcps3020h-modicon-x80-power-supply-module","title":"Schneider BMXCPS3020H Modicon X80 Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMXCPS3020H\u003c\/strong\u003e is an isolated DC power supply module from the Modicon X80 range, designed for automation systems operating in extended-temperature and demanding environmental conditions. It accepts a 24-48 V DC primary supply and provides separate power outputs for I\/O module logic and the processor. Its reinforced environmental protection supports operation from -25 to 70 deg C.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply and Output Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXCPS3020H converts the incoming DC supply into the secondary power required by the X80 backplane. It provides separate 24 V DC and 3.3 V DC outputs for the I\/O module supply and processor, and I\/O logic circuits, respectively.\u003c\/p\u003e\n\u003cp\u003eThe available output power depends on the operating temperature. At temperatures from 0 to 60 deg C, the module provides up to 31.2 W at 24 V DC and 15 W at 3.3 V DC. Across the extended -25 to 70 deg C range, these ratings are reduced to 23.4 W and 11.3 W, respectively. This derating must be considered when calculating the power budget of the installed rack.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Protection and Status Monitoring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe primary circuit has an internal fuse that is not accessible for replacement. The secondary circuit includes overload, overvoltage, and short-circuit protection for the 24 V sensor power supply connection.\u003c\/p\u003e\n\u003cp\u003eA green LED indicates that the rack voltage is OK. The module also includes a RESET pushbutton for a cold start, allowing the power supply and associated rack operation to be restarted through the designated reset function.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Connections and Mounting\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module uses a 5-pin connector for the DC supply input and protective earth, together with a 2-pin connector for the alarm relay. The specified maximum cable distances between devices are 10 m with 1.5 mm2 copper cable or 15 m with 2.5 mm2 copper cable.\u003c\/p\u003e\n\u003cp\u003eInstallation requires mounting the power supply in a compatible X80 module rack and securing it with two screws. The module has an IP20 protection rating and a maximum power dissipation of 8.5 W.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXCPS3020H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRuggedized DC Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24-48 V DC, isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e18-62.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e1.65 A at 24 V DC; 0.83 A at 48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Secondary Power\u003c\/td\u003e\n\u003ctd\u003eUp to 31.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC \/ 3.3 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e1.3 A at 24 V DC; 4.5 A at 3.3 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Power at 0 to 60 deg C\u003c\/td\u003e\n\u003ctd\u003e31.2 W at 24 V DC; 15 W at 3.3 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Power at -25 to 70 deg C\u003c\/td\u003e\n\u003ctd\u003e23.4 W at 24 V DC; 11.3 W at 3.3 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e8.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e30 A at 24 V DC; 60 A at 48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicator\u003c\/td\u003e\n\u003ctd\u003e1 green LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset Function\u003c\/td\u003e\n\u003ctd\u003eCold-start RESET pushbutton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Connection\u003c\/td\u003e\n\u003ctd\u003e2-pin connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Connection\u003c\/td\u003e\n\u003ctd\u003e5-pin connector with protective earth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eInternal, non-accessible fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eOverload, overvoltage and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Compatibility\u003c\/td\u003e\n\u003ctd\u003eNot compatible with BMEXBP..02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 10 MOhm, primary\/earth and primary\/secondary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1500 V, primary\/earth and primary\/secondary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e3 Gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e30 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% at 55 deg C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0-2,000 m; derating required from 2,000 to 5,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e4,600,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eProtective coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e3595864029771\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Resistance and Certifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXCPS3020H is designed for environments requiring additional resistance to gas, dust, sand, salt and biological contaminants. Its environmental specifications include gas resistance class Gx according to ISA S71.04, gas resistance class 3C4, dust and sand resistance class 3S4, and mold resistance class 3B2 according to IEC 60721-3-3.\u003c\/p\u003e\n\u003cp\u003eThe specified certifications and standards include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, CSA, RCM, EAC, Merchant Navy, ATEX Zone 2\/22 and IECEx Zone 2\/22.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC 61131-2, IEC 61010-2-201, UL 61010-2-201 and CSA C22.2 No. 61010-2-201.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional environmental standards:\u003c\/strong\u003e EN\/IEC 61000-6-5 and EN\/IEC 61850-3.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous location classification:\u003c\/strong\u003e Class I, Division 2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between BMXCPS3020H and BMXCPS3020?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Both models belong to the Modicon X80 DC power supply family and use a 24-48 V DC isolated primary supply. The H version is the hardened version, intended for extended environmental conditions, including an operating temperature range of -25 to 70 deg C. Their environmental and installation requirements should be checked separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can BMXCPS3020H be installed on a BMEXBP..02 backplane?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. BMXCPS3020H is a standalone power supply and is not compatible with BMEXBP..02 redundant power supply backplanes. The rack configuration must be checked before replacement or installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the BMXCPS3020H provide the same output power throughout its operating temperature range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. Its output power is derated at extended temperatures. At 0 to 60 deg C, the ratings are 31.2 W at 24 V DC and 15 W at 3.3 V DC. From -25 to 70 deg C, these ratings decrease to 23.4 W and 11.3 W, respectively.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68095782256925,"sku":"BMXCPS3020H","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXCPS3020H2.jpg?v=1794822014","url":"https:\/\/www.6gcontrols.com\/th\/products\/schneider-bmxcps3020h-modicon-x80-power-supply-module","provider":"6G Controls","version":"1.0","type":"link"}