The Schneider Electric BMXDRA1605H is a 16-channel discrete relay output module in the Modicon X80 series. It provides normally open (NO) relay contacts for switching external AC or DC loads from a PLC control system. The module features a conformal coating, IP20 protection and an extended operating temperature range of -25 to 70 deg C for installations requiring additional environmental resistance.

Technical Specifications

Parameter Specification
Model BMXDRA1605H
Brand Schneider Electric
Series Modicon X80
Product Type Discrete Relay Output Module
Number of Outputs 16
Output Type Normally Open (NO) relay contacts
Discrete Output Logic Positive
Rated Switching Current 3 A
Switching Voltage 24-240 VAC / 24-48 VDC
Minimum Switching Load 1 mA at 5 VDC
Output Response Time Less than 8 ms (activation); 10 ms (deactivation)
Insulation Resistance Greater than 10 MOhm at 500 VDC
Dielectric Strength 2000 VAC at 50/60 Hz for 1 minute
Protection Rating IP20
Protective Coating Conformal coating
Operating Temperature -25 to 70 deg C
Relative Humidity 5-95% at 55 deg C, non-condensing
MTBF 2,100,000 hours (source value; see editorial note)
Weight 0.15 kg
EAN 3595864025803
Environmental Carbon Footprint 148 kg CO2 eq.

Relay Output Function

The BMXDRA1605H uses electromechanical relay contacts to switch external loads. The PLC controls the relay coils, while the relay contacts provide the switching path for the connected field circuits. Its 16 normally open outputs remain open when the corresponding relays are de-energized and close when activated.

The relay output arrangement supports both AC and DC switching within the specified voltage ranges. The minimum switching load of 1 mA at 5 VDC is a separate contact operating parameter and should not be confused with the maximum rated switching current.

Environmental Protection and Construction

This version has a conformal protective coating intended for environments with specified resistance requirements. The manufacturer lists gas resistance classifications Gx and 3C4, dust and sand resistance classifications 3S4, salt resistance Level 2, and mould resistance Class 3B2.

The IP20 rating describes protection against access to hazardous parts and solid foreign objects. It does not indicate protection against water ingress. The extended temperature range and environmental classifications should be considered when checking suitability for the actual control cabinet installation.

PLC Platform and Installation

The BMXDRA1605H belongs to the common Modicon X80 I/O platform used with Modicon M340 and Modicon M580 programmable automation controllers. It can be installed in local or remote I/O configurations, subject to the applicable rack and system configuration requirements.

The module uses a removable 20-pin terminal block for field wiring. Installation requires mounting the module on the appropriate rack and securing it with two screws. Compatible terminal block connection options include cage-clamp, screw-clamp and removable spring-clamp types.

Frequently Asked Questions

Q: What is the difference between BMXDRA1605H and BMXDRA1605?

A: Both references belong to the Modicon X80 16-channel relay output family. The BMXDRA1605H is the ruggedized version with conformal coating and an extended operating temperature range for more demanding environmental conditions.

Q: Which PLC platforms support the BMXDRA1605H?

A: The module is specified for Modicon M340 and Modicon M580 PLC platforms, including local and remote I/O configurations. The appropriate rack and terminal block must be selected for the installation.

Q: What protection should be considered when wiring the relay outputs?

A: Output circuit protection is required. Schneider Electric documentation specifies fast-acting fuses for output protection and recommends suitable discharge or suppression components according to the AC or DC load type. Verify the wiring diagram and load conditions before commissioning.

การชำระเงิน: T/T, Western Union

ท่าเรือขนส่ง: เซี่ยเหมิน

ระยะเวลาดำเนินการ: โดยทั่วไป 1–3 วันทำการหลังยืนยันการชำระเงิน (ขึ้นอยู่กับสินค้าในสต็อก)

จัดส่งทั่วโลก: เราจัดส่งชิ้นส่วนระบบอัตโนมัติทางอุตสาหกรรมให้แก่ลูกค้าทั่วโลก โดยจะแจ้งค่าขนส่งพร้อมใบขอใบเสนอราคาของคุณ

คำถามที่พบบ่อย

คำถามที่พบบ่อยเกี่ยวกับใบเสนอราคา การจัดส่ง การรับประกัน และการคืนสินค้า

คลิก ขอใบเสนอราคา ในหน้าสินค้า แล้วส่งหมายเลขชิ้นส่วน จำนวนที่ต้องการ และประเทศปลายทางให้เรา ทีมฝ่ายขายของเราจะตอบกลับพร้อมข้อมูลสินค้าที่มีจำหน่าย ราคา และระยะเวลาจัดส่งโดยประมาณ

สินค้าที่มีอยู่ในสต็อกโดยปกติจะจัดเตรียมหลังจากได้รับการชำระเงินและยืนยันคำสั่งซื้อแล้ว คำสั่งซื้อส่วนใหญ่จัดส่งจากคลังสินค้าของเราในประเทศจีน แต่สถานที่จัดส่งอาจแตกต่างกันไปตามสต็อกปัจจุบัน

ใช่ เราจัดส่งชิ้นส่วนระบบอัตโนมัติทางอุตสาหกรรมให้ลูกค้าทั่วโลก ค่าจัดส่งและระยะเวลาในการขนส่งขึ้นอยู่กับปลายทาง น้ำหนักพัสดุ ขนาดสินค้า และข้อกำหนดการนำเข้าของท้องถิ่น

เราใช้บริการ DHL, FedEx, UPS และบริษัทขนส่งระหว่างประเทศอื่น ๆ เป็นประจำ โดยสามารถเลือกผู้ให้บริการขนส่งได้ตามปลายทาง ความเร็วในการจัดส่ง ขนาดของพัสดุ และความต้องการของลูกค้า

โดยทั่วไป สินค้าของเราครอบคลุมการรับประกัน 12 เดือน สินค้าที่มีสิทธิ์ยังสามารถส่งคืนได้ภายใต้นโยบายคืนเงินภายใน 30 วัน โปรดติดต่อทีมงานของเราก่อนส่งคืนสินค้าใด ๆ เพื่อยืนยันข้อกำหนดที่ใช้บังคับและคำแนะนำในการส่งคืน

Products FAQs

คุณอาจชอบสิ่งเหล่านี้ด้วย