ข้ามไปยังข้อมูลผลิตภัณฑ์
1 ของ 3

Schneider Electric 47600 MicroLogic 2.0E Control Unit

มีสินค้า 15 ชิ้น ทดลองใช้ฟรี
  • Manufacturer: Schneider
  • Product No.: 47600
  • Country of origin: France
  • Product Type: MicroLogic 2.0E Control Unit
  • Condition: ใหม่เอี่ยม
  • Payment: T/T, เวสเทิร์น ยูเนียน
  • Weight: 0.273 kg
  • Dimensions: 21.7 cm x 8.0 cm x 6.6 cm
  • Shipping port: เซี่ยเหมิน
  • Warranty: 12 เดือน
  • คำอธิบาย
  • Reviews
  • การจัดส่งและการชำระเงิน

Schneider Electric 47600 MicroLogic 2.0E Control Unit

Configured for overload and instantaneous short-circuit protection in MasterPact circuit breaker systems, the Schneider Electric 47600 (47600 Control Unit) provides direct electrical execution. The unit integrates MicroLogic 2.0E electronic trip functionality with energy metering capability, supporting protection parameter adjustment, fault indication, and measurement readout within MasterPact NT/NW, Compact NS, and Masterpact MT platforms.

Suffix Breakdown & Model Matrix

The supplied documentation identifies a single catalog number, 47600, associated with the MicroLogic 2.0E electronic trip unit. No official suffix subdivision or ordering matrix is specified in the provided data.

Hardware Specifications

Parameter Specification
Model 47600
Brand Schneider Electric
Product Type Electronic Control Unit
Trip Unit Name MicroLogic 2.0E
Trip Unit Technology Electronic
Application Distribution Protection
Compatible Platforms MasterPact NT, MasterPact NW, Compact NS, Masterpact MT
Number of Poles 3P, 4P
Protected Pole Configurations 3t, 4t, 3t + N/2
Protection Functions Long-Time Overload, Instantaneous Short-Circuit
Long-Time Pickup Range (Ir) 0.4 to 1 x In
Long-Time Delay Range (tr) 0.7 to 16.6 s at 7.2 x Ir; 0.7 to 24 s at 6 x Ir; 12.5 to 600 s at 1.5 x Ir
Instantaneous Pickup Range (Ii) 1.5 to 10 x Ir
Thermal Memory 20 min
Measurement Type Energy Meter
Data Communication Measurement Readout, Protection Settings, Alarm Settings
Local Indication 3 Fault LEDs, 1 Internal Error LED
Display Type Digital Display
Network Type AC
Network Frequency 50/60 Hz
Mounting Mode Fixed, Drawout
Operating Temp -25 to 70 deg C
Storage Temp -40 to 85 deg C
Dimensions 21.7 cm x 8.0 cm x 6.6 cm
Weight 273 g

Profinet and Backplane Integration Considerations

Within Schneider Electric breaker protection architectures, the MicroLogic 2.0E control unit exchanges operational data related to metering, alarm status, and protection settings. Firmware compatibility between the trip unit and the host breaker assembly should be verified before replacement activities. Parameter synchronization, trip rating selection, and protection configuration must match the installed breaker frame and rated current setting to maintain protection coordination.

The electronic protection platform supports adjustable pickup and delay characteristics, allowing I/O density scaling across multiple breaker ratings ranging from 630 A to 6300 A without changing the fundamental protection philosophy of the installation.

Frequently Asked Questions

Q: Does the 47600 MicroLogic 2.0E support hot replacement while the breaker remains energized? A: The provided documentation does not specify hot-swap capability. Replacement procedures should follow the applicable MasterPact maintenance instructions and site lockout requirements.

Q: Can the protection settings be adjusted locally? A: Yes. The unit provides adjustable long-time and instantaneous protection settings through the electronic trip unit interface and digital display.

Q: Is earth-fault protection included in this model? A: No. The supplied specification identifies overload and instantaneous short-circuit protection only and lists earth-leakage protection as unavailable.


Field Installation Guidelines

  • Verify breaker frame compatibility before installing the control unit into MasterPact NT, NW, MT, or compatible Compact NS assemblies.
  • De-energize equipment and follow lockout/tagout procedures prior to removal or insertion of the trip unit.
  • Inspect connector contacts and backplane interfaces for contamination, oxidation, or mechanical damage before installation.
  • Maintain separation between power conductors and low-level communication wiring to reduce conducted electrical noise.
  • Confirm that current rating, pickup settings, and delay settings correspond to the protection study for the distribution system.
  • After commissioning, verify LED indication, display operation, and trip parameter configuration through functional testing procedures.

การชำระเงิน: T/T, Western Union

ท่าเรือขนส่ง: เซี่ยเหมิน

ระยะเวลาดำเนินการ: โดยทั่วไป 1–3 วันทำการหลังยืนยันการชำระเงิน (ขึ้นอยู่กับสินค้าในสต็อก)

จัดส่งทั่วโลก: เราจัดส่งชิ้นส่วนระบบอัตโนมัติทางอุตสาหกรรมให้แก่ลูกค้าทั่วโลก โดยจะแจ้งค่าขนส่งพร้อมใบขอใบเสนอราคาของคุณ

คำถามที่พบบ่อย

คำถามที่พบบ่อยเกี่ยวกับใบเสนอราคา การจัดส่ง การรับประกัน และการคืนสินค้า

คลิก ขอใบเสนอราคา ในหน้าสินค้า แล้วส่งหมายเลขชิ้นส่วน จำนวนที่ต้องการ และประเทศปลายทางให้เรา ทีมฝ่ายขายของเราจะตอบกลับพร้อมข้อมูลสินค้าที่มีจำหน่าย ราคา และระยะเวลาจัดส่งโดยประมาณ

สินค้าที่มีอยู่ในสต็อกโดยปกติจะจัดเตรียมหลังจากได้รับการชำระเงินและยืนยันคำสั่งซื้อแล้ว คำสั่งซื้อส่วนใหญ่จัดส่งจากคลังสินค้าของเราในประเทศจีน แต่สถานที่จัดส่งอาจแตกต่างกันไปตามสต็อกปัจจุบัน

ใช่ เราจัดส่งชิ้นส่วนระบบอัตโนมัติทางอุตสาหกรรมให้ลูกค้าทั่วโลก ค่าจัดส่งและระยะเวลาในการขนส่งขึ้นอยู่กับปลายทาง น้ำหนักพัสดุ ขนาดสินค้า และข้อกำหนดการนำเข้าของท้องถิ่น

เราใช้บริการ DHL, FedEx, UPS และบริษัทขนส่งระหว่างประเทศอื่น ๆ เป็นประจำ โดยสามารถเลือกผู้ให้บริการขนส่งได้ตามปลายทาง ความเร็วในการจัดส่ง ขนาดของพัสดุ และความต้องการของลูกค้า

โดยทั่วไป สินค้าของเราครอบคลุมการรับประกัน 12 เดือน สินค้าที่มีสิทธิ์ยังสามารถส่งคืนได้ภายใต้นโยบายคืนเงินภายใน 30 วัน โปรดติดต่อทีมงานของเราก่อนส่งคืนสินค้าใด ๆ เพื่อยืนยันข้อกำหนดที่ใช้บังคับและคำแนะนำในการส่งคืน

Products FAQs

คุณอาจชอบสิ่งเหล่านี้ด้วย